Specifications

1.Range: 0-300mm/0-12inch
2.Material:stainless steel (4cr13)
3.Four-way measurements
4.certificate:CE
5.Display: LCD

  •SPECIFICATIONS

1.size: 41.5 cm           

2.packing details:

QTY PER CTNN.W/G.WCTN SIZE
20 PCS16/18KG 46X31X27 cm

3. material: 4cr13

4.package: plastic casing or blister with paper card or according to your requirements.

TECHNICAL SPECIFICATIONS

1.Outside Jaws:           Measure External Length

2.Inside Jaws:              Measure Internal Length

3.Measuring Range:     0-300mm/0-12in

4.Resolution:                  0.01mm/ 0.0005in

5.Accuracy:                     ± 0.02mm/ 0.001in (<100mm)

                                    ±0.03mm/0.001in(>100-200mm)                                      

6.Repeatability:               0.01mm / 0.0005in

7.Max Measuring Speed: 1.5m/sec, 60in/sec

8.Measuring System:       Linear Capacitance measuring system

9.Display:                         LCD Screen

10.Construction Material:  Stainless Steel

11.Power:                          One alkaline lithium button cell battery 1.5v,TYPE LR44.

                                      Capacity-180MAH

12.Working  Temperature: 5°c-40°c/41 to 104 degree f

13.Note:                  Accuracy affected in environments exceeding 80% relative humidity.MAINTENANCE INSTRUCTIONS

1. Keep the calliper clean and dry (liquid can damage the slider)

2. Use a clean, dry cloth to clean all surfaces -do not use solvents or solvent based cleaners.

3. To save power, turn off the unit when not in use.

Avoid contact with electricty and /or electronic devices

•BATTERY REPLACEMENT

Flashing display indicates low battery. To replace battery, remove battery cover by sliding cover in 

the direction indicated and replace battery with positive side facing out.

 

TROUBLE SHOOTING

Falure

Cause 

Measure

Display flashes

Low battery

Replace battery 

Display does not change when 

slider is moved

System locked

Remove battery and replace after

30 seconds to reset system

Accuracy less than +/-0.001mm

Dirt in the sensor

Remove slider cover and its assembly,

clean with compress air 5kgs/cm2

No display on LCD

1. improper battery position

2. Low battery

1. Remove battery cover and check 

battery position 

2. Replace battery. 

 Digital Vernier Calipers

Digital Vernier Calipers 

 Digital Vernier Calipers

 

 

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2004
Factory Size
1,000-3,000 square meters
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs