iTEMP TMT182 Temperature head transmitter
Transformation of sensor signals into stable and standardized output signals for all industries
Product Overview
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), it also transfers resistance and voltage signals using HART® communication. It can be installed as an intrinsically safe apparatus in Zone 1 hazardous areas. Swift and easy operation, visualization and maintenance by PC using operating software.
Benefits
Front end unit or panel unit operation using the hand operating module or PC
High accuracy in total ambient temperature range
Fault signal on sensor break or short circuit, NAMUR NE 43 compliant
EMC to NAMUR NE 21, CE
Ex-Certification: ATEX Ex ia and dust zone 22 in compliance with EN 50281-1; FM IS; CSA IS
Galvanic isolation
SIL 2 compliant
Field of application
Temperature head transmitter with HART® -protocol for converting various input signals into an scalable 4 to 20 mA analog output signal
Input: Resistance thermometer (RTD), thermocouple (TC), Resistance transmitter, voltage transmitter (mV)
HART® -protocol for front end unit or panel unit operation using the hand operating module (DXR275, DXR375) or PC (e. g. ReadWin 2000 or FieldCare)
Technical information
| Measuring Principle | Head transmitter | |
| Input | 1 x RTD, TC, Ohm, mV | |
| Output | 1 x analog 4...20 mA | |
| Auxiliary power supply | 11,5...35 V DC (standard-version) 11,5...30 V DC (Ex-version) | |
| Communication | HART-protocol | |
| Installation | Terminal head form B | |
| Accuracy | (Pt100, -50...200 °C) <= 0,2 K (Pt100, -58...392 °F) <= 0,4 °F | |
| Galvanic isolation | yes | |
| Certification | UL Ex IS UL Ex NI GL marine approval GOST Ex i FM IS,NI,Class I,Div.1+2,Group ABCD CSA IS,NI,Class I,Div.1+2,Group ABCD ATEX II1G Ex ia IIC T4/T5/T6 ATEX II3G Ex nA IIC T4/T5/T6 ATEX II3D ATEX II1G Ex ia IIC T6, II3D ATEX II3G Ex nA IIC T6, II3D FM+CSA IS,NI,Class I,Div.1+2,Group ABCD CSA General Purpose IECEx Ex ia IIC T6/T5/T4 ATEX IECEx II1G Ex ia IIC T6 Ga NEPSI Ex ia IIC T4-T6 NEPSI Ex nA II T4-T6 | |
Send Inquiry to This Supplier
You May Also Like
-
Honeywell EC7890B1028 Burner Control EC7890 B 1028 Honeywel EC7890B1028/UNegotiableMOQ: 1 Piece
-
Water Transfer Mould Temperature MachineNegotiableMOQ: 2 Sets
-
PC4 Intelligent Thermal PTZ Camera High Precision, Perimeter Security MonitoringNegotiableMOQ: 50 Pieces
-
16A Electric Heating Touch Screen Thermostat With WIFI for Floor Heating SystemUS$ 20 - 35MOQ: 10 Pieces
-
Gas Cooker Thermocouple Universal Gas ThermocoupleNegotiableMOQ: 1
-
Industrial Object Thermometer/Industrial ThermometerUS$ 23.5 - 23.5MOQ: 10 Pieces
-
Liyi Plastic HDT Point Tester Vicat Softening TemperatureUS$ 2,580 - 5,680MOQ: 1 Set
-
RC-5 USB Waterproof Temperature RecorderUS$ 10.6 - 19.2MOQ: 1 Piece
-
Easy to Use Black Body Radiation Source With Good GuaranteeUS$ 1,800 - 1,800MOQ: 1 Set
-
HONEYWELL 2MLR-CPUH/F MASTERLOGIC 200 PROGRAMMABLE LOGIC CONTROLLER 2MLR-CPUH HoneywelNegotiableMOQ: 1 Piece