Home > Electrical & Electronics > Transmitter > Pressure Transmitter > 3095MFP Integral Orifice Flowmeter

3095MFP Integral Orifice Flowmeter

3095MFP Integral Orifice Flowmeter photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Japan
Model Number:
3095MFP
Payment & Shipping
Payment Methods:
Port of Shipment:
Xi'an
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Japan
Model Number 3095MFP

 

Rosemount 3095MFP Integral Orifice Flowmeter

 

Specifications

3095MFP Performance Specifications


Repeatability
±0.1%


Line Sizes
• 1/2-in. (15 mm)
• 1-in. (25 mm)
• 11/2-in. (40 mm)


Output
Two-wire 4–20 mA, user-selectable for DP, AP, GP, PT, mass flow,
or totalized flow. Digital HART protocol superimposed on 4–20 mA
signal, available to any host that conforms to the HART protocol.


Performance Statement Assumptions
• Measured pipe I.D
• Electronics are trimmed for optimum flow accuracy


Sizing
Contact an Emerson Process Management sales representative
for assistance. A “Configuration Data Sheet” is required prior to
order for application verification.


3095MFP Functional Specifications


Service
• Liquid
• Gas
• Steam


Power Supply
4–20 mA option
• External power supply required. Standard transmitter
(4–20 mA) operates on 11 to 55 Vdc with no load


Process Temperature Limits
Direct Mount Transmitter
• –40 to 450 °F (–40 to 232 °C)
Remote Mount Transmitter
Transmitter Temperature Limits


Ambient
• –40 to 185 °F (–40 to 85 °C)
• With Integral Mount LCD Display: –4 to 175 °F (–20 to 80 °C)


Storage
• –50 to 230 °F (–46 to 110 °C)
• With Integral Mount LCD Display: –40 to 185 °F (–40 to 85 °C)


Maximum Working Pressure
Transmitter
• Zero to two times the absolute pressure range with a
maximum of 3626 psia (250 bar).
Flowmeter
• Pressure retention per ANSI B16.5 600 lb. or
DIN PN100


Static Pressure Limits
Operates within specification between static pressures of 0.5 psia
(0.03 bar-A) and the URL of the static pressure sensor.


System Reference Accuracy
Percentage (%) of mass flow rate(1)
(1) Without associated straight run piping, discharge coefficient
uncertainty can add up to 1.5% - 5% additional error. Consult the
factory for additional information.

(1) High temperature option code G must be selected.
TABLE 37. 1195 Pressure Limits
Line Size
Process


Connection

Maximum Working
Pressure @ 100 °F(1)(2)
(1) For pressure ratings at temperatures less than -20 °F (-29 °C)
or above 100 °F (38 °C) consult an Emerson Process
Management representative.
(2) Transmitter static pressure range may limit maximum working
pressure. Refer to Static Pressure Ranges

3095MFP Integral Orifice Flowmeter

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2010
Factory Size
1,000-3,000 square meters
Total Employees