Wholesale VOC Monitor / Detector
Specifications
1.LCD display VOC level and temp&RH%2.1x 0~10VDC output and 2 x relay outputs
3.RS485 optional
IAQ is a comprehensive index, including room temperature, humidity, fresh air, and diverse low concentrations air contaminants. Monitoring IAQ is very important to guarantee healthy life and work.
F2000IAQ-VOC is specially designed to detect indoor air quality in offices and home environments. Its internal gas sensor has high sensitivity not only to VOC's such as toluene emitted from wood finishing and construction products but also to other air contaminants which are emitted by cigarette smoke, ammonia and H2S. It’s also sensitive to carbon monoxide, alcohol, natural gas and smell from people’s body. So it is more suitable for monitoring IAQ than other sensors which one is only for one kind of gas.
F2000IAQ-VOC also can be used as a controller in ventilation system and AC system.
¨ Features
u Real time monitor ambiance air quality with a mix gas sensor
u Japanese semiconductor gas sensor with 5~7 years long life
u Monitor temperature and relative humidity
LCD display air quality as well as temperature and humidity, fan status etc. Makes reading and operating easy and accurate.
u user-friendly setting buttons
u Temperature and humidity compensation makes the IAQ measurement more consistent in different environments
u Modbus RS-485 communication interface optional, 15KV antistatic protection, independent base address setting
u Up to 1x0~10V analog output and 2xrelay dry-contact outputs
u Two alternatives for the analog output : linearized over full range output or PID control output.
u The relays can be selected to control IAQ , temperature or humidity (programmable setting)
u Timer of turning-off function for the ventilator device from 0.5 to 12 hours.
u Low power consumption
¨ Application
u Ambiance air quality detection and alert
u Ventilation control
u Air quality monitors
u Odor monitors.
¨ Specifications
Gas detected |
VOCs ( toluene emitted from wood finishing and construction products); Cigarette smoke( hydrogen, carbon monoxide); ammonia and H2S, alcohol, natural gas and smell by people’s body. |
|
Sensing element |
Semiconductor mix gas sensor |
|
Power supply |
24VAC/VDC |
|
Consumption |
2.8 W |
|
Response Time |
<5 minutes for 90% step change |
|
Warm up time |
48 hours (first time), 1 hour (normal operation) |
|
VOC’s measuring range |
1~30ppm |
|
Display resolution |
0.1ppm |
|
Temperature & Humidity Sensor |
Temperature |
Relative Humidity |
Sensing element |
NTC |
Capacitive sensor |
Measuring range |
0~50°C |
0 -95%RH |
Accuracy |
±0.5°C (25°C, 40%-60%RH) |
±4.5%RH (25°C, 40%-60%RH) |
Display resolution |
0.5°C |
1%RH |
Stability |
±0.5°Cper year |
±1%RH per year |
Analog output |
0~10VDC linear output or PID control output, programmable selection |
|
Output resolution |
10Bit |
|
Relay output |
Two dry contact outputs with programmable selection to control VOC, temperature, humidity. Rated switching current 2A(220VAC/30VDC), resistance load |
|
Modbus interface |
Modbus RS-485 protocol. 19200bps(default) 15KV antistatic protection, independent base address, 31 max network nodes |
|
Operation temperature |
0~50°C(32~122°) |
|
Operation humidity |
0~95%RH,non condensing |
|
Storage conditions |
0~50°C(32~122°F) |
|
Net Weight |
280g |
|
Dimensions |
120mm×90mm×24mm |
|
Installment standard |
65mm×65mm or 2”×4” wire box |
|
Interface connections (Max.) |
10 terminals |
|
Wiring standard |
Wire section area <1.5mm2 |
|
Quality System |
ISO 9001 |
|
Programming and selection |
Via DIP switch and external push-buttons |
|
Outputs (max.) |
1~2 dry contact relay outputs, 1X0~10V output |
|
Models Guide
Detection Gas |
|
VOC’s (toluene emitted from wood finishing and construction products), Cigarette smoke(hydrogen, carbon monoxide), Ammonia and H2S, alcohol, natural gas and smell by people’s body. |
Code |
Model |
|
2 |
0 |
Standard type |
4 |
0 |
Standard type with RS-485 communication interface |
Code |
Amount of analog output |
0 |
No analog output |
1 |
1 * 0 – 10 VDC output |
Code |
Amount of dry contact output |
0 |
No |
1 |
1 relay dry contact output |
2 |
2 relay dry contact outputs |
Code |
Power supply |
C |
24VAC/VDC |
F2000IAQ |
VOC |
— |
X1 |
X2 |
X3 |
X4 |
— |
C |
Example: F2000IAQ-VOC-2011 indicates the monitor can supply one analog output and one relay dry contact output.
Send Inquiry to This Supplier
You May Also Like
-
Lightweight 0.8kg CJG10 Optical Interference CH4 Detector Lithium Battery PoweredNegotiableMOQ: 1 Piece
-
Honeywell SiF4 Gas Detector MIDAS-E-HFX MIDAS-K-HFX Original and NewNegotiableMOQ: 1 Piece
-
LD 200 Halogen Gas Freon CFCs HCFCs HFCS HFO Refrigerant Leak Detector LD-200NegotiableMOQ: 1
-
High Quality Gas Leak DetectorNegotiableMOQ: 1 Piece
-
Dual Digital Breath Alcohol TesterNegotiableMOQ: 2000 Pieces
-
Sulfur Hexafluoride SF6 Recycling Device With Function of SF6 FillingUS$ 2,000 - 50,000MOQ: 1 Set
-
Factory Offer NO Gas Detector OEM Gas DetectorUS$ 400 - 600MOQ: 10 Sets
-
BrACAudit Panther-3 (with Camera, Built-in Printer) Breath Alcohol AnalyzerUS$ 568.00 - 568.00MOQ: 3 Pieces
-
CALIBRE Ethylene Golycol Tester Antifreeze TesterNegotiableMOQ: 1020 Pieces
-
Industria Online Portable Gas TesterUS$ 250 - 300MOQ: 1 Unit