Details of 11/0.38kv dry type electrical transformer
Characteristics of 11/0.38kv dry type electrical transformer
Benefits:
1. High mechanical strength and strong short circuit resistance ability;
2. Good moisture resistance and run with 90% humidity;
3. Advanced structure, small dimension, light weight and low partial discharge;
4. High insulation level and equal electric field distribution;
5. maintenance free;
6. Run with 140% rated load under forced air cooling;
7. Fireproof, explosion-proof, pollution-free and low-noise and able to be directly installed in the load center.
Application:
The product has been widely used in places with high fireproofing requirements, such as power transmission and transformation system, high-rise building, commercial center, sport stadium, petrochemical enterprise, metro, station and airport. In China, the epoxy resin cast dry-type power transformer has the richest manufacturing experience and the best running performance.
Standards of 11/0.38kv dry type electrical transformer
Service condition | |
Normal Condition Ambient temperature Indoor -5°C to +40°C Outdoor -10°C to +40°C Humidity 90% Altitude ≤1000m Pollution Level I-Light Level II-Medium Earthquake UBC Zone 3
| Special Condition Ambient temperature Indoor -15°C to +40°C, -25°C to +40°C Outdoor -10°C to +50°C, -25°C to +40°C -40°C to +40°C Humidity 95%,98% Altitude ≤2000m, ≤3000m, ≤4000m Pollution Level III-Heavy, Level IV-Very Heavy Earthquake UBC Zone 4 |
Standard | |
IEC 60076-1 Power transformers-Part 1: General IEC 60076-2 Power transformers-Part 2: Temperature rise IEC 60076-3 Power transformers-Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-4 Power transformers-Part 4: Guide to the lightning impulse and switching impulse testing IEC 60076-5 Power transformers-Part 5: Ability to withstand short circuit IEC 60076-10 Power transformers-Part 10: Determination of sound levels IEC 60076-11 Power transformers-Part 11: Dry-type transformers
IEEE C57.12.00 General Requirements for Liquid-Immersed Distribution Power, and Regulating Transformers IEEE C57.12.01 General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid-Cast and/or Resin Encapsulated Windings | |
Ratings | |
IEC Standard
Rated Voltage: 3.6 kV – 7.2 kV – 12 kV – 17.5 kV – 24 kV – 36 kV – 52 kV – 72.5 kV – 100 kV – 123 kV – 145 kV − 170 kV – 245 kV
Rated Insulation Level: Common Value: 20kV – 40kV – 60kV – 75kV – 95kV – 125kV – 145kV – 170kV – 250kV – 325kV – 380kV – 450kV – 550kV – 650kV – 750kV – 850kV – 950kV – 1050kV Across the isolating distance: 23kV – 46kV – 70kV – 85kV – 110kV – 145kV – 165kV – 195kV – 290kV – 375kV – 440kV – 520kV – 630kV – 750kV – 860kV – 950kV – 1050kV – 1200kV
Rated Frequency: 50Hz, 60Hz
Rated normal current: 1A – 1.25A – 1.6A – 2A – 2.5A – 3.15A – 4A – 5A – 6.3A – 8A – 10A – 12.5A – 16A – 20A – 25A – 31.5A – 40A- 50A – 63A – 80A – 100A – 125A – 160A – 200A – 250A – 315A– 400A – 500A – 630A – 800A – 1000A – 1250A – 1600A – 2000A – 2500A – 3150A – 4000A – 5000A – 6300A
Rated kVA 30kVA – 50kVA – 80kVA – 100kVA – 125kVA – 160kVA – 200kVA – 250kVA – 315kVA – 400kVA – 500kVA – 630kVA – 800kVA – 1000kVA – 1250kVA – 1600kVA – 2000kVA – 2500kVA – 3150kVA – 4000kVA – 5MVA – 6.3MVA – 8MVA – 10MVA – 12.5MVA – 16MVA – 20MVA
| |
IEEE Standard
Rated KVA Single-phase transformer: 5kVA – 10kVA – 15kVA – 25kVA – 37.5kVA – 50kVA – 75kVA – 100kVA – 167kVA – 250kVA – 333kVA Three-phase transformer: 15kVA – 30kVA – 45kVA – 75kVA – 112.5kVA – 150kVA – 225kVA – 300kVA – 500kVA – 750kVA – 1000kVA – 1500kVA – 2000kVA – 2500kVA – 3750kVA – 5MVA – 7.5MVA –10MkVA – 12MVA – 15MVA – 20MVA – 25MVA – 30MVA – 37.5MVA
Rated Voltage 1.2kV – 2.5kV – 5.0kV – 8.7kV – 15.0kV – 25kV – 34.5kV – 46.0kV – 69.0kV – 115.0kV – 138.0kV – 161kV – 230.0kV – 345kV
BIL 30kV – 45kV – 60kV – 75kV- 95kV – 110kV – 150kV – 200kV – 250kV – 350kV – 450kV – 550kV – 650kV – 750kV – 825kV – 900kV – 1050kV – 1175kV | |
Related Transformer product in our company
Please click the following link for detailed information if there is any interest


Workshop for Dry Type Power Transformer
Certificate for 11/0.38kv dry type electrical transformer
Service of 11/0.38kv dry type electrical transformer
| 1. | Pre sale service |
| a. | make technical solution |
| b. | send quotation, technical data sheet and drawing |
| c. | prepare power transmission plan, testing plan,and shipment plan |
| 2. | In sale service |
| a. | supervise the manufacturing schedule totally in accordance with the plan |
| b. | send photos to customer during every manufacturing process(hold point) |
| c. | inform the customer one week before testinng. |
| 3. | After sale service |
| a. | installation and commissioning, training the workers |
| b. | quick response within 12 hours any time |
| c. | provide 12 months gurantee period normally. |
Contact person: Ms.Kayla Wang
Tel: +86-312-6775757
Fax: +86-312-6775656
Whatsapp: +8615822478551
Skype: sales02(at)
Click following " Send " for more detailed informaiton and price directly!
Thank you!! :)
Send Inquiry to This Supplier
You May Also Like
-
DANFOSS Controller MCX08M080G0310NegotiableMOQ: 1 Piece
-
Wholesale Silicon Steel Electrical Steel Sheet Transformer Iron Core From ChinaNegotiableMOQ: 50 Sets
-
CEEG China Amorphous Core Dry-Type Transformer - Ultra Low No-Load Loss (Up to 70% Savings), High Efficiency, Custom KVANegotiableMOQ: 1 Unit
-
ABB DSTDN020 3BSE003238R1NegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
ABB 1SBL177001R1101 AF16-30-01-11 ContactorNegotiableMOQ: 1 Piece
-
Original Honeywell Burner Ignition Controller TBC2800A1000 for Burner Spare PartNegotiableMOQ: 1 Piece
-
100% New Omron PLC Digital Input Unit CJ1W-ID211 StockNegotiableMOQ: 1 Piece
-
HONEYWELL 1PC Honeywell TMG740-3 Mod.43-35 Controller TMG7403 New Expedited Shipping Honeywel Tmg 740 -3NegotiableMOQ: 1 Piece
-
HONEYWELL RM7800L1087 Honeywell Burner ControlNegotiableMOQ: 1 Piece