Step up Step Down Three-phase Transformer With Price Dyn11
Details of step up step down three-phase transformer with price Dyn11
Advantages of step up step down three-phase transformer with price Dyn11
1. | Have good ability withstand short-circuit |
a. | The dry-type transformers are casted with epoxyresin,which are made of high quality materials by means of a strict process with advanced production and testing devices. |
b. | The product features high reliability and long service life.In accordance with different operation environment, it can be equipped with different protection casings or without casing |
c. | It can replace the oil-immersed transformer and be used in the high buildings,business centers,airports, tunnels,chemical plants,nuclear power stations and watercrafts ect
|
2. | Low loss, low noise, high reliability |
3. | Reliability: All in-service product have no damages |
Standards of step up step down three-phase transformer with price Dyn11
Service condition | |
Normal Condition Ambient temperature Indoor -5°C to +40°C Outdoor -10°C to +40°C Humidity 90% Altitude ≤1000m Pollution Level I-Light Level II-Medium Earthquake UBC Zone 3
| Special Condition Ambient temperature Indoor -15°C to +40°C, -25°C to +40°C Outdoor -10°C to +50°C, -25°C to +40°C -40°C to +40°C Humidity 95%,98% Altitude ≤2000m, ≤3000m, ≤4000m Pollution Level III-Heavy, Level IV-Very Heavy Earthquake UBC Zone 4 |
Standard | |
IEC 60076-1 Power transformers-Part 1: General IEC 60076-2 Power transformers-Part 2: Temperature rise IEC 60076-3 Power transformers-Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-4 Power transformers-Part 4: Guide to the lightning impulse and switching impulse testing IEC 60076-5 Power transformers-Part 5: Ability to withstand short circuit IEC 60076-10 Power transformers-Part 10: Determination of sound levels IEC 60076-11 Power transformers-Part 11: Dry-type transformers
IEEE C57.12.00 General Requirements for Liquid-Immersed Distribution Power, and Regulating Transformers IEEE C57.12.01 General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid-Cast and/or Resin Encapsulated Windings | |
Ratings | |
IEC Standard
Rated Voltage: 3.6 kV – 7.2 kV – 12 kV – 17.5 kV – 24 kV – 36 kV – 52 kV – 72.5 kV – 100 kV – 123 kV – 145 kV − 170 kV – 245 kV
Rated Insulation Level: Common Value: 20kV – 40kV – 60kV – 75kV – 95kV – 125kV – 145kV – 170kV – 250kV – 325kV – 380kV – 450kV – 550kV – 650kV – 750kV – 850kV – 950kV – 1050kV Across the isolating distance: 23kV – 46kV – 70kV – 85kV – 110kV – 145kV – 165kV – 195kV – 290kV – 375kV – 440kV – 520kV – 630kV – 750kV – 860kV – 950kV – 1050kV – 1200kV
Rated Frequency: 50Hz, 60Hz
Rated normal current: 1A – 1.25A – 1.6A – 2A – 2.5A – 3.15A – 4A – 5A – 6.3A – 8A – 10A – 12.5A – 16A – 20A – 25A – 31.5A – 40A- 50A – 63A – 80A – 100A – 125A – 160A – 200A – 250A – 315A– 400A – 500A – 630A – 800A – 1000A – 1250A – 1600A – 2000A – 2500A – 3150A – 4000A – 5000A – 6300A
Rated kVA 30kVA – 50kVA – 80kVA – 100kVA – 125kVA – 160kVA – 200kVA – 250kVA – 315kVA – 400kVA – 500kVA – 630kVA – 800kVA – 1000kVA – 1250kVA – 1600kVA – 2000kVA – 2500kVA – 3150kVA – 4000kVA – 5MVA – 6.3MVA – 8MVA – 10MVA – 12.5MVA – 16MVA – 20MVA
| |
IEEE Standard
Rated KVA Single-phase transformer: 5kVA – 10kVA – 15kVA – 25kVA – 37.5kVA – 50kVA – 75kVA – 100kVA – 167kVA – 250kVA – 333kVA Three-phase transformer: 15kVA – 30kVA – 45kVA – 75kVA – 112.5kVA – 150kVA – 225kVA – 300kVA – 500kVA – 750kVA – 1000kVA – 1500kVA – 2000kVA – 2500kVA – 3750kVA – 5MVA – 7.5MVA –10MkVA – 12MVA – 15MVA – 20MVA – 25MVA – 30MVA – 37.5MVA
Rated Voltage 1.2kV – 2.5kV – 5.0kV – 8.7kV – 15.0kV – 25kV – 34.5kV – 46.0kV – 69.0kV – 115.0kV – 138.0kV – 161kV – 230.0kV – 345kV
BIL 30kV – 45kV – 60kV – 75kV- 95kV – 110kV – 150kV – 200kV – 250kV – 350kV – 450kV – 550kV – 650kV – 750kV – 825kV – 900kV – 1050kV – 1175kV | |
Related Transformer product in our company
Please click the following link for detailed information if there is any interest


Workshop for Dry Type Power Transformer
Certificate for step up step down three-phase transformer with price Dyn11
Service of step up step down three-phase transformer with price Dyn11
| 1. | Pre sale service |
| a. | make technical solution |
| b. | send quotation, technical data sheet and drawing |
| c. | prepare power transmission plan, testing plan,and shipment plan |
| 2. | In sale service |
| a. | supervise the manufacturing schedule totally in accordance with the plan |
| b. | send photos to customer during every manufacturing process(hold point) |
| c. | inform the customer one week before testinng. |
| 3. | After sale service |
| a. | installation and commissioning, training the workers |
| b. | quick response within 12 hours any time |
| c. | provide 12 months gurantee period normally. |
Contact person: Ms.Kayla Wang
Tel: +86-312-6775757
Fax: +86-312-6775656
Whatsapp: +8615822478551
Skype: sales02(at)
Click following " Send " for more detailed informaiton and price directly!
Thank you!! :)
Send Inquiry to This Supplier
You May Also Like
-
DANFOSS Controller MCX08M080G0310NegotiableMOQ: 1 Piece
-
Electrical Power Distribution Epoxy Resin Cast Dry Type Isolation TransformerNegotiableMOQ: 50 Sets
-
CEEG China Amorphous Core Dry-Type Transformer - Ultra Low No-Load Loss (Up to 70% Savings), High Efficiency, Custom KVANegotiableMOQ: 1 Unit
-
ABB DSTDN020 3BSE003238R1NegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
ABB 1SBL177001R1101 AF16-30-01-11 ContactorNegotiableMOQ: 1 Piece
-
Omron Temperature Controller E5CC-RX3A5M-000NegotiableMOQ: 1 Piece
-
Omron Thermostat E5CSL-RTCNegotiableMOQ: 1 Piece
-
100% New Omron PLC Digital Input Unit CJ1W-ID211 StockNegotiableMOQ: 1 Piece
-
Original Honeywell Burner Ignition Controller TBC2800A1000 for Burner Spare PartNegotiableMOQ: 1 Piece