High Quality Step Down Transformer 11kv Phase Cast Resin Dry-type Transformer 315kva
Details of High quality step down transformer 11kv phase cast resin dry-type transformer 315kva
Characteristics of High quality step down transformer 11kv phase cast resin dry-type transformer 315kva
Benefits:
1. High mechanical strength and strong short circuit resistance ability;
2. Good moisture resistance and run with 90% humidity;
3. Advanced structure, small dimension, light weight and low partial discharge;
4. High insulation level and equal electric field distribution;
5. maintenance free;
6. Run with 140% rated load under forced air cooling;
7. Fireproof, explosion-proof, pollution-free and low-noise and able to be directly installed in the load center.
Application:
The product has been widely used in places with high fireproofing requirements, such as power transmission and transformation system, high-rise building, commercial center, sport stadium, petrochemical enterprise, metro, station and airport. In China, the epoxy resin cast dry-type power transformer has the richest manufacturing experience and the best running performance.
Standards of High quality step down transformer 11kv phase cast resin dry-type transformer 315kva
Service condition | |
Normal Condition Ambient temperature Indoor -5°C to +40°C Outdoor -10°C to +40°C Humidity 90% Altitude ≤1000m Pollution Level I-Light Level II-Medium Earthquake UBC Zone 3
| Special Condition Ambient temperature Indoor -15°C to +40°C, -25°C to +40°C Outdoor -10°C to +50°C, -25°C to +40°C -40°C to +40°C Humidity 95%,98% Altitude ≤2000m, ≤3000m, ≤4000m Pollution Level III-Heavy, Level IV-Very Heavy Earthquake UBC Zone 4 |
Standard | |
IEC 60076-1 Power transformers-Part 1: General IEC 60076-2 Power transformers-Part 2: Temperature rise IEC 60076-3 Power transformers-Part 3: Insulation levels, dielectric tests and external clearances in air IEC 60076-4 Power transformers-Part 4: Guide to the lightning impulse and switching impulse testing IEC 60076-5 Power transformers-Part 5: Ability to withstand short circuit IEC 60076-10 Power transformers-Part 10: Determination of sound levels IEC 60076-11 Power transformers-Part 11: Dry-type transformers
IEEE C57.12.00 General Requirements for Liquid-Immersed Distribution Power, and Regulating Transformers IEEE C57.12.01 General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid-Cast and/or Resin Encapsulated Windings | |
Ratings | |
IEC Standard
Rated Voltage: 3.6 kV – 7.2 kV – 12 kV – 17.5 kV – 24 kV – 36 kV – 52 kV – 72.5 kV – 100 kV – 123 kV – 145 kV − 170 kV – 245 kV
Rated Insulation Level: Common Value: 20kV – 40kV – 60kV – 75kV – 95kV – 125kV – 145kV – 170kV – 250kV – 325kV – 380kV – 450kV – 550kV – 650kV – 750kV – 850kV – 950kV – 1050kV Across the isolating distance: 23kV – 46kV – 70kV – 85kV – 110kV – 145kV – 165kV – 195kV – 290kV – 375kV – 440kV – 520kV – 630kV – 750kV – 860kV – 950kV – 1050kV – 1200kV
Rated Frequency: 50Hz, 60Hz
Rated normal current: 1A – 1.25A – 1.6A – 2A – 2.5A – 3.15A – 4A – 5A – 6.3A – 8A – 10A – 12.5A – 16A – 20A – 25A – 31.5A – 40A- 50A – 63A – 80A – 100A – 125A – 160A – 200A – 250A – 315A– 400A – 500A – 630A – 800A – 1000A – 1250A – 1600A – 2000A – 2500A – 3150A – 4000A – 5000A – 6300A
Rated kVA 30kVA – 50kVA – 80kVA – 100kVA – 125kVA – 160kVA – 200kVA – 250kVA – 315kVA – 400kVA – 500kVA – 630kVA – 800kVA – 1000kVA – 1250kVA – 1600kVA – 2000kVA – 2500kVA – 3150kVA – 4000kVA – 5MVA – 6.3MVA – 8MVA – 10MVA – 12.5MVA – 16MVA – 20MVA
| |
IEEE Standard
Rated KVA Single-phase transformer: 5kVA – 10kVA – 15kVA – 25kVA – 37.5kVA – 50kVA – 75kVA – 100kVA – 167kVA – 250kVA – 333kVA Three-phase transformer: 15kVA – 30kVA – 45kVA – 75kVA – 112.5kVA – 150kVA – 225kVA – 300kVA – 500kVA – 750kVA – 1000kVA – 1500kVA – 2000kVA – 2500kVA – 3750kVA – 5MVA – 7.5MVA –10MkVA – 12MVA – 15MVA – 20MVA – 25MVA – 30MVA – 37.5MVA
Rated Voltage 1.2kV – 2.5kV – 5.0kV – 8.7kV – 15.0kV – 25kV – 34.5kV – 46.0kV – 69.0kV – 115.0kV – 138.0kV – 161kV – 230.0kV – 345kV
BIL 30kV – 45kV – 60kV – 75kV- 95kV – 110kV – 150kV – 200kV – 250kV – 350kV – 450kV – 550kV – 650kV – 750kV – 825kV – 900kV – 1050kV – 1175kV | |
Related Transformer product in our company
Please click the following link for detailed information if there is any interest


Workshop for Dry Type Power Transformer
Certificate for High quality step down transformer 11kv phase cast resin dry-type transformer 315kva
Contact person: Ms.Kayla Wang
Tel: +86-312-6775757
Fax: +86-312-6775656
Whatsapp: +8615822478551
Skype: sales02(at)
Click following " Send " for more detailed informaiton and price directly!
Thank you!! :)
Send Inquiry to This Supplier
You May Also Like
-
DANFOSS Controller MCX08M080G0310NegotiableMOQ: 1 Piece
-
Wholesale Silicon Steel Electrical Steel Sheet Transformer Iron Core From ChinaNegotiableMOQ: 50 Sets
-
CEEG China Amorphous Core Dry-Type Transformer - Ultra Low No-Load Loss (Up to 70% Savings), High Efficiency, Custom KVANegotiableMOQ: 1 Unit
-
ABB DSTDN020 3BSE003238R1NegotiableMOQ: 1 Piece
-
WOODWARD 8901-457 – Industrial Control Module for Engine/Turbine Protection and Speed ManagementNegotiableMOQ: 1 Bag
-
ABB 1SBL177001R1101 AF16-30-01-11 ContactorNegotiableMOQ: 1 Piece
-
Original Honeywell Burner Ignition Controller TBC2800A1000 for Burner Spare PartNegotiableMOQ: 1 Piece
-
100% New Omron PLC Digital Input Unit CJ1W-ID211 StockNegotiableMOQ: 1 Piece
-
HONEYWELL 1PC Honeywell TMG740-3 Mod.43-35 Controller TMG7403 New Expedited Shipping Honeywel Tmg 740 -3NegotiableMOQ: 1 Piece
-
HONEYWELL RM7800L1087 Honeywell Burner ControlNegotiableMOQ: 1 Piece