Home > Instruments & Meters > Test Instrument > Test Machine > KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector

KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector

KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-1
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-2
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-3
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-4
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-5
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector photo-6
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Shanghai, China
Brand Name:
KINGDAK, KINGDAK
Model Number:
KD-AP1500, KD-FP1500
Payment & Shipping
Payment Methods:
Port of Shipment:
SHANGHAI
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Shanghai, China
Brand Name KINGDAK, KINGDAK
Model Number KD-AP1500, KD-FP1500

KD-FP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer

APPLICATION: 
This instrument is used for analyzing & measuring the content & concentration of elements (K, Na, Li, Ca, Ba). It can be widely applied to agriculture (soil, fertilizer, tobacoo), industry (cement, glass, ceramics, mineral orore powder, fireproof material), food (wine, water), laboratory, clinical experiments and pathology research(serum, urine, plasma), etc. 

CHARACTERISTICS:    
With 5 channels and be able to detect K, Na, Li, Ca, Ba elements.   
With K, Na, Li, Ca, Ba five filters, which can detect three kinds of elements, show three kinds of element content simultaneously. 
1. Operates on propane, butane or liquefied petroleum gas. 
2. Standard accessories: Air-compressor, PC software or micro-printer. 
3. LCD Display, touch panel with numeric keypad. 
4. Single point calibration & calibration curve can be saved. 
5. RS232 interface, external computer or printer. With a mist separator. 
Model: FP1200 
1. Measurement range: K: 0-100ppm; Na: 0-100ppm; 2. Measurement Limit: K: 0.01ppm; Na: 0.01ppm; 
3. Drift: Drift &le: 3% (after 30 minutes when the instrument stability) 
4. Sample Rate: 4 ~ 6ml/min 
5. Linearity: Better than the best results of the intermediate value of 2% (single-point CAL) 
6. Response Time: Less than 8s 
7. Time Stability: Less than 15 seconds (when the sample was taken after the flame) 
8. Calibration Methods: Straight line, broken line, secondary fitting 
9. Size & Weight: 530X510X580mm & 27kg 
Model: FP1301 
1. Measurement range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; 
2. Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; 
3. Drift: Drift &le: 3% (after 30 minutes when the instrument stability) 
4. Sample Rate: 4 ~ 6ml/min 
5. Linearity: Better than the best results of the intermediate value of 2% (single-point CAL) 
6. Response Time less than 8s 
7. Time Stability: Less than 15 seconds (when the sample was taken after the flame) 
8. Calibration Methods: Straight line, broken line, secondary fitting 
9. Size & Weight: 530X510X580mm & 27kg 
Model: FP1401 
1. Measurement range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Ca: 0-1000ppm; 
2. Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; Ca: 0.1ppm; 
3. Drift: Drift &le: 3% (after 30 minutes when the instrument stability) 
4. Sample Rate: 4 ~ 6ml/min 
5. Linearity: Better than the best results of the intermediate value of 2% (single-point CAL) 
6. Response Time: Less than 8s 
7. Time Stability: Less than 15 seconds (when the sample was taken after the flame) 
8. Calibration Methods: Straight line, broken line, secondary fitting 
9. Size & Weight: 530X510X580mm & 27kg 
Model: FP1500  
1. Measurement range: K: 0-100ppm; Na: 0-100ppm; Li: 0-100ppm; Ca: 0-1000ppm; Ba: 0 3000ppm 
2. Measurement Limit: K: 0.01ppm; Na: 0.01ppm; Li: 0.025ppm; Ca: 0.1ppm; Ba: 10ppm; 
3. Drift: Drift &le: 3% (after 30 minutes when the instrument stability) 
4. Sample Rate: 4 ~ 6ml/min 
5. Linearity: Better than the best results of the intermediate value of 2% (single-point CAL) 
6. Response Time: Less than 8s 
7. Time Stability: Less than 15 seconds (when the sample was taken after the flame) 
8. Calibration Methods: Straight line, broken line, secondary fitting

KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detectorKD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector

KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector

KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector 
KD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detectorKD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detectorKD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detectorKD-AP1500(Measure K,Na,Li,Ca,Ba) Flame Photometer/detector

 

 

 

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2011
Factory Size
Below 1,000 square meters
Total Employees
Fewer than 5 People

Recommended Categories

Explore top categories and find suppliers for your specific needs