GR Series Full Automatic Laboratory Hospital Medical Sterilization Equipment
GR SERIES Autoclave
Opening way: flip top
Type DA: Fully automatic, basic model
Type DF: Automatic water feeding and fast cooling based on Type DA
Type DR: Automatic drying function based on Type DF
Function Table
|
Feature |
GR60DR GR85DR GR110DR |
GR60DF GR85DF GR110DF |
GR60DA GR85DA GR110DA |
|
Sterilization mode |
Solid mode: Heating-Sterilizing-Exhausting and air cooling |
YES |
YES |
YES |
|
Solid with drying mode: Heating-Sterilizing-Exhausting and air cooling -Water drainage-drying |
YES |
NO |
NO |
|
|
Liquid with warming mode: Heating-Sterilizing-Precooling-Exhausitng-Warming |
YES |
YES |
YES |
|
|
Liquid mode: Heating-sterilizing-Precooling-Steam exhausting |
YES |
YES |
YES |
|
|
Waste Mode: Heating-Sterilizing-Steam exhausting and air cooling |
YES |
YES |
YES |
|
|
Agar Mode: Heating-Melting-Warming |
YES |
YES |
YES |
|
Automatic water feeding |
STANDARD |
STANDARD |
NO |
|
Water level sensor |
STANDARD |
STANDARD |
NO |
|
Cooling fan |
STANDARD |
STANDARD |
OPTIONAL |
|
Load thermometer |
OPTIONAL |
OPTIONAL |
OPTIONAL |
|
Printer |
OPTIONAL |
OPTIONAL |
OPTIONAL |
|
Memory system |
Create 60 procedures |
Create 60 procedures |
Create 20 procedures |
|
Specification Table
GR60DR |
GR85DR |
GR110DR |
|
GR60DF |
GR85DF |
GR110DF |
|
GR60DA |
GR85DA |
GR110DA |
|
Capacity(L) |
60 |
85 |
110 |
Chamber Dimension(Dia*H, mm) |
400×505 |
400×700 |
400×895 |
Chamber material |
SUS304 |
||
Rated power supply |
220V/50Hz |
||
Rate power(W) |
2900 |
4600 |
4600 |
Sterilization temperature |
105—138℃ |
||
Range of sterilization time |
1—300minutes |
||
Melting temperature |
60—100℃ |
||
Range of melting time |
1—300minutes |
||
Warming temperature |
45—60℃ |
||
Range of melting time |
1—9999minutes |
||
Preset range of drying time |
1-300minutes(only for GR60DR/GR85DR/GR110DR) |
||
Preset range of cooling lock OPEN temperature |
40-99℃ for solid and agar modes and 40-80℃ for liquid and waste modes |
||
Preset range of steam exhausting temperature |
73—104℃ |
||
Exhausting mode |
Fully automatic internal discharging Embedded with a steam trapping bottle |
||
Way of opening lid |
Flip type |
||
Preset range of timer |
0 minute-6 days delayed |
||
Preset range of timer |
0-0.6MPa |
||
Preset temperature of chamber lid opening |
presettable |
||
Rated working pressure |
0.27 MPa |
||
Controller |
“inspiration”fast-speed microcomputer intelligent control system |
||
Safety device |
“eight-column evenly distributed” interlockingdevice, electric double inner locks, dry scorch protection, overpressureprotection, safety valve, over temperature protection, over current and shortcircuit protection, leakage protection, cooling lock, anti-scald chamber coverand bench, automatic troubleshooting |
||
Accessories |
drainage hose, water plate, exhaustbottle |
||
|
Two stainless steel baskets |
Three stainless steel baskets |
Three stainless steel baskets |
Other accessories |
Stainless steel pail, printer, cooling fan, Article thermometer optional |
||
Send Inquiry to This Supplier
You May Also Like
-
Egg Liquid Pasteurizer /HTST Pasteurization Machine for Egg Process PlantNegotiableMOQ: 1
-
Electric Spray for Medical PlacesUS$ 13.5 - 14.5MOQ: 40 Pieces
-
MAST-A High Efficiency Large Vacuum Autoclave Shinva Steam SterilizerNegotiableMOQ: 1 Set
-
Beiqi Salon Furniture Good Quality Tool Disinfection CabinetNegotiableMOQ: 10 Pieces
-
Cheap Pet Hospital IncineratorUS$ 28,000 - 42,000MOQ: 1 Set
-
CE Standard 7g High Concentration Output Adjustable Air Ozonator for Pharmaceutical IndustryNegotiableMOQ: 1 Set
-
UHT Sterilizer With Mixer Tank and PumpUS$ 2,000 - 10,000MOQ: 1 Set
-
Chemical Label for Autoclave Sterilization CheckUS$ 6 - 12MOQ: 10 Pieces
-
SELON STEAM STERILIZER AUTOCLAVENegotiableMOQ: 2 Sets
-
MMQ-SD Series Hospital Table Top Steam Autoclave (LED Display)US$ 1,800 - 2,500MOQ: 1 Set