Home > Products > Water bath > JK-WBN-300A New Thermostatic Water Bath(Economy)
JK-WBN-300A New Thermostatic Water Bath(Economy)
- 500 Set / Sets per Month
- SHANGHAI CHINA
- Credit Card
- 100Liter Industrial High Temperature Heating Water Oil Bath Circulator Circulating Pump For 100L Jacketed Reactor
- 50Liter High Temperature Heating Water Oil Bath Circulator Circulating Pump GXC-50
- 30Liter Industrial High Temperature Heating Water Oil Bath Circulator GXC-30
- 20Liter Industrial Heating Equipment Water Oil Bath Circulator GXC-20
- 10L Industrial Heating Water Oil Bath Circulator Price GXC-10
- Artificial climate incubator
Product Details
Brand Name: | JKI | Model Number: | JK-WBN-300A | Place of Origin: | Shanghai, China |
Product Description
JK-WBN Series New Thermostatic Water Bath(Economy)
I. Scope of Application:
It is used for precise temperature keeping and auxiliary heating by industrial and mining enterprises, colleges and universities, scientific research institutes and various labs, etc.
II. Specification
Item no. | 140339 | 140340 | 140341 | 140342 | 140343 | 140344 | ||
Economy | Luxury | |||||||
Model | JK-WBN-150A | JK-WBN-300A | JK-WBN-600A | JK-WBN-150B | JK-WBN-300B | JK-WBN-600B | ||
Voltage | AC220V±10%, 50Hz~60Hz | |||||||
Input power | 300W | 500W | 800W | 300W | 500W | 800W | ||
Temperature range | RT+5℃~99℃ | RT+5℃~99℃ | ||||||
Display screen | LED | Display screen | ||||||
Temperature stability | ±0.5℃ | ±0.3℃ | ||||||
Resolution | 0.1℃ | |||||||
Timing range |
| 0~999min | ||||||
Volume | 5L | 13L | 28L | 5L | 13L | 28L | ||
Interior dimension L*W*H (mm) | 300*150*150 | 295*235*200 | 495*295*200 | 300*150*150 | 295*235*200 | 495*295*200 | ||
Dimension L*W*H (mm) | 550*250*220 | 580*320*270 | 800*500*300 | 550*250*220 | 580*320*270 | 800*500*300 | ||
Package size(mm)L*W*H | 650*350*320 | 680*420*370 | 860*550*400 | 650*350*320 | 680*420*370 | 860*550*400 | ||
N.W | 11kg | 11.8kg | 17.4kg | 11kg | 11.8kg | 17.4kg | ||
Price RMB/USD | 1250/198 | 1500/238 | 1800/290 | 1450/230 | 1700/270 | 2000/318 |
III. Structural Description:
1. It has a stainless inner layer and the cover can be removed at random.
2. The temperature control is via the high-precision temperature control instrument. And the temperature control is precise and reliable.
3. Digital display. microcomputer controlled.
IV. Usage:
1. Fill clean warm water into water tank up to 1/2 ~2/3 of the full height.
2. Set the power switch to “ON” and then figures will appear on the temperature control instrument panel, indicating the power supply is on.
3. Set temperature, When the measured temperature reaches the set temperature, the heating will be interrupted and the heating indicator will go out, and the temperature will become stable after 60 minutes of temperature keeping. If the temperature in the water tank exceeds the set temperature over 2 °C(alarm temperature can be set arbitrarily), the alarm indicator of the temperature control instrument is on and the power of the heater will be automatically switched off in the meantime.
Symbol | Name | Setting range | Description | Factory set value |
AL | Alarming setting | 0-Full Range 0.0-Full Range | When temperature is beyond SP+AL,the ALM indicator turn on. The buzzer sounds and the heating power turn off. |
|
CL | Refrigeration control setting | 0-Full Range 0.0-Full Range | When the temperature less than SP+COL, the refrigeration point is turn on to drive the compressor. | without this function |
P | Proportional Band | 1-Full Range 1.0-Full Range | Proportional control action. If P is larger, then the gain of system is lower. It only use on the heating side. |
|
I | Integral Time | 0-3600 seconds | Integrated time constant. I larger, then the integrated action is smaller. |
|
D | Derivative Time | 0-3600 seconds | Derivative time constant. D larger, then the derivative action is also larger D can overcome overshoot. I=0and D=0 is called half proportional control. |
|
Ar | Overshoot Control(re-setting) | 1-100% | At on-off PID control, the value of Ar is a constant which equals 1.5-2times of the ratio of on time to the on-off period in the equilibrium state, In the half proportional control, the Ar equals coefficient/P. |
|
T | Heating period | 1-300seconds | For the thyristor output it is abut 1-3seconds.For those equipment that the superfluous power provided is comparatively larger, select larger T would decrease the stable error caused by PID control. |
|
Pb | Zero point adjust (intersection) | -100-100 -100.0-100.0 | When the zero error comparatively smaller and the full point error comparatively larger, to update this value should be needed. Ordinary for pt100 ,updating this value is rarely needed.. |
|
PK | Full point adjust(intercept) | -1000-1000 seconds | When the zero error comparatively larger and the full point error also comparatively larger, to update this value should be needed. PK=4000×(setting value-actual value)/actual value. For pt100 adjusting this value is need at first time. |
|
Ct | Refrigeration control Time delayed | 0-3600seconds | When measuring value reaches its alarm value, the alarm relay output will be +delayed this time… | Without this function |
dp | The decimal point setting | 0;1 | When D=0 the display resolving power is 1°C and when DP=1 the display resolving power is 0.1°C |
|
rH | The range setting | 0- 400°C 0.0-400.0 | Adjusting rH can make the instrument range equals 0-rH(°C) |
|
LK | Password key | 0-255 | When LK=18 the parameters listed above then the above parameters can be updated. |
|
V. Precautions
1. The shell of the water tank shall be grounded effectively to guarantee the safe use.
2. Before filling water, never press down the power switch so as to prevent the electrical heating tube from being burnt.
3. When any sound and light alarms are sent out from the water tank, please check whether the set temperature deviates from the normal range or not; if not, stop use and invite the professional personnel to inspect it or hand it over to our factory for repair.
4. Unless necessary, never disassemble the side plate of the temperature control unit so as to guarantee the safety
VI. Maintenance
1. Always keep the internal and external of the water tank clean; do not wipe the shell with the chemical solution, which can cause chemical reaction, to prevent any chemical reaction.
2. If the instrument is not to be used for a long time, cover it with a plastic thin film dust shroud and place it in a drying room so as to prevent the temperature control instrument from being moisturized and out of use.
3. The instrument is not suitable to be used in the environments of high voltage, heavy current, intense magnetic field or corrosive gases to prevent the instrument from being damaged by intervention and prevent the persons from the risks of the electroshock.
VII. Failure Handling Methods
Problems | Causes | Handling methods |
1. No supply | 1.The plug is not inserted well or the wire is disconnected. | 1. Insert the plug and connect the wire. |
2. Fuse is open. | 2. Replace the fuse. | |
2. The temperature in the cabinet does not increase. | 1. The set temperature is low. | 1. Adjust the set temperature. |
2. The electric heater does not work. | 2. Replace the electric heater. | |
3. The temperature control instrument does not work. | 3.Replace temperature control instrument. | |
4. The cyclic fan does not work. | 4. Replace the fan. | |
3.The set temperature has a big difference from the temperature in the cabinet. | 1.The temperature sensor does not work. | 1. Change temperature sensor. |
2.The fine tuning potentiometer for setting temperature is not adjusted well. | 2. Adjust the potentiometer. | |
4.The over-temperature alarm is abnormal. | 1. The set temperature is low. | 1. Adjust the set temperature. |
2.The temperature control instrument does not work. | 2. Replace the temperature control instrument. |
Contact Us
- Shanghai Jingke Scientific Instrument Co., Ltd.
- Contact nameLeo Luo
- Phone86-21-34637408
- AddressBldg. 2, No. 328, Minle Road
- Constant temperature and humidity incubator (internal humidification upgrade)
- HC-B056 Laboratory equipment digital Water bath shaker Lab shaker machine for sale
- HC-B057 medical devices equipment Factory supply Orbital type gas bath stable temperature shaker/Orbital shaker
- HC-B084C High Quality Laboratory Equipment Tri-Gas CO2 Incubator 160L for cell culture
- HC-B045 Factoray Direct 2 Holes Stainless Steel Laboratory Digital Thermostatic Water Bath
- HC-B093 Professional Laboratory Bacterial Culture Anaerobic Incubator with LCD Display and UV Lamp
- HC-B048 High Quality 8 hole large volume water bath/ Water bath (600*300*120mm) for laboratory magnetic stirrer water bath
- HC-B046 factory price laboratory Water bath price / (300mm*300mm*120 mm) thermostatic water bath
- HC-B057 laboratory equipment hot sale Orbital shaker Orbital type gas bath stable temperature Lab shaker
- HC-B047 Good Quality Water bath (460*300*120mm)/circulating water bath
- HC-B049 Factory Price Digital laboratory Oil bath/Thermostat lab instrumentoil bath
- HC-B048 Popular Water bath (600*300*120mm)/Cheap laboratory magnetic stirrer water bath
- HC-B049 Digital Oil bath/oil bath
- HC-B048 Water bath (600*300*120mm)/magnetic stirrer water bath
- HC-B045 Hot sale Water bath(300mm*160mm*120mm) with a nice price/immersion bath water heater
- HC-B049 Digital Oil bath/oil bath
- HC-B082A Laboratory incubator 50L Electrothermal stable temperature incubator
- HC-B051 Orbital type water bath stable temperature shaker/shaking water bath
- HC-B049 China original Digital Oil bath with Promotion Price/oil bath
- HC-B051 water bath shaker /Orbital type water bath stable temperature controlled shaker/shaking water bath
- HC-B045 Medical laboratory immersion Water bath Thermostatic water bath heater 1-4 Pieces / Water bath
- HC-B083 Hot Sale Lab Electrothemal stable temperature Incubator/bacteria incubator(15L-270L) with a low price
- HC-B082A Laboratory incubator 50L Electrothermal stable temperature incubator
- HC-B046 Cheapest Water bath(300mm*300mm*120 mm)/water bath price
Popular Searches
Recommended Products
- lithium molecular sieve oxygen zeolite adsorbents for PSA nitrogen separation
- Red Powder Vitamin B12 (Food Grade CAS 68-19-9)
- High Quality Vb12 Vitamin B12 CAS 68-19-9
- High Purity API Nutrition Vitamin B12 Cyanocobalamin CAS No 68-19-9
- Hot Sales Folic Acid /Biotin /Inositol Vitamin a /C / E / D Vitamin B1 B3 B5 B6 B7 B9 B12/L-Arginine /L-Lysine/L-Isoleucine Vitamin Raw Powder
- Hot Sale Vitamin B9 Feed/Food Additives Pharmaceutical Grade Raw Powder Folic Acid Vitamin a/Vitamin C/Vitamin D/Vitamin B1/B5/B6/B7/B9/B12/Vitamin E
- lithium molecular sieves adsorbents for nitrogen oxygen separation oxygen generators
- 13X-APG molecular sieves zeolite for natural gas purification and removal of co2 and h2s
- 13X-HP molecular sieves zeolite for PSA nitrogen gas deep separation adsorption
- 5A zeolite molecular sieves for liquid paints deep drying and purification
- CAS 1629579-82-3 Diaminopropyl diglycol maleic acid Diaminopropyl diglycol dimaleate other chemical products
- ZHOUF CAS 66-99-9 2-naphthalene formaldehyde 2-naphthylene aldehyde Other chemical products
Find Similar Products By Category
- Chemicals > Lab Supplies > Laboratory Thermostatic Devices
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Leo Luo
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-