Home > Industrial Equipment & Components > Power & Generating Sets > Gas Generator > Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates

Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates

Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates photo-1
Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates photo-2
Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates photo-3
Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates photo-4
Camda Biogas Power Generator /Biomass Generator/Bio Gas Engine/Biomass Power Plant/Biogas Cogeneration With CE&ISO Certificates photo-5
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Guangdong, China
Brand Name:
Camda
Model Number:
KDGH30-G~KDGH120-G
Payment & Shipping
Payment Methods:
Port of Shipment:
SHENZHEN
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Guangdong, China
Brand Name Camda
Model Number KDGH30-G~KDGH120-G
Output Type AC Three Phase
Speed 1500/1800rpm
Frequency 50Hz/60Hz
Rated Power 30-120KW

Product Description

 

Camda Biogas Power Generator/Biogas Electrical Generator/Biogas Engine Generator/Biogas Cogeneration From 20KW to 500KW.

 

 

 

Advantages For Biomass Electric Generator (gas engine)

 

  Natural gas and biogas as fuel 
  CE,ISO international quality control certificate approval 
  Low operation cost 
  Low gas consumption

1.Adopt gas engine block,so the instructure is very strong. Also it is easy for customer to get maintenance spare parts.

2. Adopt advanced Hall ignition sensor and Highly capable USA Altronic ignition system, the engine ignition will be more reliable and easier to start. Besides,there is Top End Center mark on the engine,it is easy for users to adjust the top end certer when commissioning generator set.

3. Adopt ComAp Interligen/Interlisys controller to make synchronization for generator set, all the parameters can be set in the program and can realize the remote controlling through cell phone or computer.

4.The gas inlet pressure is only 2~12kPA,so almost all city pipe gas pressure can be satisfied,not to mention biogas. So there is no need for customer to install blower to increase pressure and save cost for you.

5. Electrical Air/Gas mixer. The mixer guarantees optimum air-fuel ratio to improve efficiency and reduce NOx emission. Unique air-fuel ratio adjusting system is suitable for 30%~90% methane concentration.

6. Long designed overhaul term: 25000~30000 hours

7. Comply with CE standard, ISO9001:2008 quality management system, ISO14001:2004 and OHSAS 18001:2007.

 

 

Packaging & Shipping

 

 

 

 

Our Services

  

Biomass Electric Generator Standard Working Conditions


1.Gas genset can run for continuously at rated power on the conditions of:

Atmospheric Pressure:100kPa,Ambient Temp:20°C, Relative Humidity:30%.



2.Gas genset can also run stably and reliably on the conditions of:

Ambient Temp-40°C~+40°C, Relative Humidity<90%(20°C),Altitude≤1000m above sea level.

 

 

Natural Gas Power Plant in Nigeria

 

 

Fuel Requirements of gas engine


1.Adapted Gas:Biogas(Marsh gas/Biomass/Methane gas),natural gas,lpg,cng,coalmine gas,wood gas,sygas,etc.

2.Acceptable Biogas pipeline pressure:2~12kPa

3.Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ).Genset output power will increase as the gas heat valueincrease,if use low heat value gas for fuel(Heat value<5500kcal/Nm3, it willl lower the power efficiency.

4.CH4 content≥50%.

5.Gas doesn’t include free water or free materials (the size of impurities should be less than 5μm.)

6.Sulphur content≤200mg/Nm3, the excessive sulphur in impurity gas should be removed.

 

 

 

 

 

 

 

Gas Engine Generator Specifications

 

 

 

 

 

 Model 

   Item    

KDGH30-G

KDGH50-G

KDGH80-G

KDGH120-G

Power (KVA/kWe)

37/30

62/50

100/80

150/120

Rated Voltage (V)

400/230

400/230

400/230

400/230

Frequency (Hz)

50

50

50

50

Speed (RPM)

1500

1500

1500

1500

Engine model

HG4B

HG6B

HGN14

HGN14

Mechanical

Efficiency (%)

36.5

37.4

37.8

38.5

Electrical

Efficiency (%)

34.6

35.5

35.7

36.4

Rated current(A)

45

90

135

217

Voltage   Stabilized regulation

≤±1.5%

≤±1.5%

≤±1.5%

≤±1.5%

Voltage Instantaneous regulation

≤±20%

≤±20%

≤±20%

≤±20%

Voltage Recovery time(S)

≤1

≤1

≤1

≤1

Voltage Fluctuation ratio

≤1%

≤1%

≤1%

≤1%

Voltage Wave aberration ratio

≤5%

≤5%

≤5%

≤5%

Frequency     Stabilized regulation

≤1%(adjustable)

≤1%(adjustable)

≤1%(adjustable)

≤1%(adjustable)

Frequency Instantaneous regulation

-10%~12%

-10%~12%

-10%~12%

-10%~12%

Frequency   Recovery time(S)

≤7

≤7

≤7

≤7

Frequency Fluctuation ratio

≤1%

≤1%

≤1%

≤1%

Generator Insulation class

H

H

H

H

Noise level(dB)

≤95

≤95

≤95

≤95

Dry weight(kg)

900

1100

1700

2600

Dimension(mm)

1800x710x1350

2250x820x1400

2450x820x1550

2800x1100x1550

 

 

 

 

 

 

 

Company Information

 

  

 

Biogas power generation plant pictures in Australia  

 

 

 

FAQ

 

  

 

CE and ISO9001-2000/ISO 14001/ISO18001 Quality Control Certificate of  Cummins Biogas Power Generator/Biogas Electrical Generator/Biogas Engine Generator/Biogas Cogeneration 

 

 

 

 

 

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2001
Factory Size
10,000-30,000 square meters
Total Employees
201 - 300 People

Recommended Categories

Explore top categories and find suppliers for your specific needs