Home > Health & Medicine > Veterinary > Veterinary Instruments > Veterinary Top Infusion Pump on Sale

Veterinary Top Infusion Pump on Sale

Veterinary Top Infusion Pump on Sale photo-1
Veterinary Top Infusion Pump on Sale photo-2
Veterinary Top Infusion Pump on Sale photo-3
Veterinary Top Infusion Pump on Sale photo-4
US$ 349 - 449 MOQ: 1 Unit
Key Specifications
Get Latest Price
Place of Origin:
Beijing, China
Brand Name:
OEM
Model Number:
IP-50V
Payment & Shipping
Payment Methods:
Port of Shipment:
Beijing
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Beijing, China
Brand Name OEM
Model Number IP-50V
Properties Other, Diagnosis & Injection

 

Features:

1. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etc, which gain patents

2. HD LCD Display, high capacity words, friendly user interface, dynamically display working status

3. Compatible with any brand of infusion sets after correct calibration

4. Preset Solution Volume to greatly reduce the workload of nurses

5. Work mode: ml/h and drop/min can switch freely 

6. Three levels of occlusion: high, middle and low

7. Purge function

8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed.

9. Power Source: AC100-240V, 50/60Hz; Internal Battery

10. Automatically record the settings of last infusion can be available per customers request

11. Language: English, Poland, Latvian, Russian etc


Specification:

1. Infusion Rate 0.1ml/h---1200ml/h (1ml/h step ,input 016 when set the rate from 800 to 1200ml/h)


2. Rate Accuracy within±5% (after correct calibration)


3. Purge Rate 100ml/h---1200ml/h(can be calibrated)


4. Volume Limit 0ml---9999ml   Total Infusion Volume  0---9999.9 ml


5. Alarm Pressure 
   High: 800mmHg±200mmHg(106.7kPa±26.7kPa)
   Medium: 500mmHg±100mmHg(66.7kPa±13.3kPa)
   Low: 300mmHg±100mmHg(40.7kPa±13.3kPa)


6. Alarms             
end of injection, occlusion, door open, bubbles in the tube, wrong setting,
low battery, AC power pulled out etc


7. Power source 100V---240V  50/60Hz


8. Internal rechargeable Li battery volume≥1,600mAh  
   4 hours internal battery backup
 

9. Bubble Detector ultrasonic wave detector, detection sensitivity ≥25μL


10. KVO Speed 1ml/h---5ml/h (1ml/h step)


11. Power Consumption 15VA


12. Operation Environment Temperature  +5----+40 degree
                                            Relative Humidity  20----90%  
                                            Storage Temperature  -30-----+55 degree
                                            Humidity   ≤95%
                                            Atmospheric Pressure  50.10KPa----106.0KPa


13. Weight 1.8kg


14. Dimension 140mm (L)x 157mm (W)x 220mm (H)


15. Infusion set brand Compatible with any brand


16.Forbidden Not support blood Infusion
 

17. Package 1pc per each Carton, 2.8KG

Features:

1. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etc, which gain patents

2. HD LCD Display, high capacity words, friendly user interface, dynamically display working status

3. Compatible with any brand of infusion sets after correct calibration

4. Preset Solution Volume to greatly reduce the workload of nurses

5. Work mode: ml/h and drop/min can switch freely 

6. Three levels of occlusion: high, middle and low

7. Purge function

8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed.

9. Power Source: AC100-240V, 50/60Hz; Internal Battery

10. Automatically record the settings of last infusion can be available per customers request

11. Language: English, Poland, Latvian, Russian etc


Specification:

1. Infusion Rate 0.1ml/h---1200ml/h (1ml/h step ,input 016 when set the rate from 800 to 1200ml/h)


2. Rate Accuracy within±5% (after correct calibration)


3. Purge Rate 100ml/h---1200ml/h(can be calibrated)


4. Volume Limit 0ml---9999ml   Total Infusion Volume  0---9999.9 ml


5. Alarm Pressure 
   High: 800mmHg±200mmHg(106.7kPa±26.7kPa)
   Medium: 500mmHg±100mmHg(66.7kPa±13.3kPa)
   Low: 300mmHg±100mmHg(40.7kPa±13.3kPa)


6. Alarms             
end of injection, occlusion, door open, bubbles in the tube, wrong setting,
low battery, AC power pulled out etc


7. Power source 100V---240V  50/60Hz


8. Internal rechargeable Li battery volume≥1,600mAh  
   4 hours internal battery backup
 

9. Bubble Detector ultrasonic wave detector, detection sensitivity ≥25μL


10. KVO Speed 1ml/h---5ml/h (1ml/h step)


11. Power Consumption 15VA


12. Operation Environment Temperature  +5----+40 degree
                                            Relative Humidity  20----90%  
                                            Storage Temperature  -30-----+55 degree
                                            Humidity   ≤95%
                                            Atmospheric Pressure  50.10KPa----106.0KPa


13. Weight 1.8kg


14. Dimension 140mm (L)x 157mm (W)x 220mm (H)


15. Infusion set brand Compatible with any brand


16.Forbidden Not support blood Infusion
 

17. Package 1pc per each Carton, 2.8KG

 

Veterinary Top Infusion pump on sale

Veterinary Top Infusion pump on saleVeterinary Top Infusion pump on sale

 Veterinary Top Infusion pump on saleVeterinary Top Infusion pump on saleVeterinary Top Infusion pump on saleVeterinary Top Infusion pump on sale

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2014
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People

Recommended Categories

Explore top categories and find suppliers for your specific needs