Home > Health & Medicine > Medical Equipment > Medical Diagnosis Equipment > Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional

Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional

Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-1
Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-2
Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-3
Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-4
Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-5
Multi Parameter Maternal Fetal Monitor for Mothers and Infantssingle Twins Optional photo-6
Negotiable MOQ: 1 Set (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
Brandnew
Place of Origin:
Beijing, China
Model Number:
RFM-900B
Payment & Shipping
Payment Methods:
Port of Shipment:
Tianjin or Beijing
Delivery Detail:
Delivery time depends on order quantity.
Brand Name Brandnew
Place of Origin Beijing, China
Model Number RFM-900B
Maternal/Fetal Monitor
 

Features :

1 12.1" color LCD flip screen.
2 Ergonomic handle design, easy to carry and move.
3 Normal FHR(120-160bpm) area backgroud mark
4 Manual/automatic fetal movement function.
5 Multi-alarming functions ,including tachycardia,bradycardia,printing time-over indicator,shortage of paper, etc.
6 Built-in durable thermal printer with real-time and playback printing function , MTBF more than 20 years ,

 

7 152mm wide paper, compatible with American and international standard paper .
8 High sensitive multi-wafer Transducer with low ultrasound power (optional 1MHZ-3MHZ).
9 Windows operation system,, easy and convenient coding input keyboard ,

 

 

Technical Parameters:

 

Fetal heart rate :

Multi-wafer,wide wave beam,pulse working mode, high sensitivity
Ultrasound intensity:<5mW/cm2
Working frequency:1.0--3.0MHZ(optional)
Measurement scope:30-240bpm
Alarming scope :
upper limit:160,170,180,190 bpm
lower limit:90,100,110,120 bpm
Resolution:±1bpm
Accuracy:±1bpm

 


Toco Pressure:

Measuring range:0-100(pressure unit)

Nonlinear error:≤±10%

 

 

 

Fetal Movement:

Manual/automatic FM

 

ECG

 

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:  
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.  
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.    
Accuracy: Error rate < 20%          
Undetected rate < 20%  
ST section  
Scope:     ±0.8mV
Precision :  
< ±0.05mV

 

SpO2

 

Detection scope:   0%-100%
Accuracy         ±1%     90%-100%                
                 ±2%      70%-89% 

 

NIBP 

 

Theory Electric oscillator  
Cuff gassing time   less than 15 seconds 
First-time gassing pressure: dynamic state 24kPa
(180 mmHg) 
Manual selection: 9.3kPa
(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg) 
18.6kPa
(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg), 
Automatic detection period: 1 minute to 240 minutes  
Stop size
:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min
(90 min -240min) 
Detection scope:  
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa
~31.3kPa       (20mmHg~235mmHg) 
Detection accuracy  
Static pressure: ±3mmHg
Pulse rate:  ±2%

 

Resp 

 

Chest impedance method or concentration of carbon dioxide at end of respiration  
Scope of chest impedance method     0 time/minute – 100 minutes/minute  
Precision of chest impedance method  time/minute  
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg
; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute
(including baby) 
Detection precision of respiration rate: ±1 time/minute 

 

Temp

 

 Single/double path  

Type:    Vascular/surface temperature  
Scope:    20°C
~50°C 
Accuracy:  ±0.2°C

Multi Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optional

Multi Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optionalMulti Parameter Maternal Fetal Monitor for mothers and infantssingle twins optional

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2014
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People