Home > Products > Static Synchronous Compensator(STATCOM/SVG) > Static synchronous compensator for electric arc furnace
Static synchronous compensator for electric arc furnace
- 500 Set / Sets per Month
- Zhuhai/Shenzhen/HongKong/Macau
- T/T Credit Card PayPal
Product Details
Place of Origin: | Guangdong, China | Brand Name: | Wanlida | Model Number: | WLD-HSVG |
Product Description
Static synchronous compensator for electric arc furnace
Main Functions
Improve the stability of power transmission
In long distance transmission system, Static synchronous compensator (STATCOM) can not only compensate the power line losses caused byreactive power, increase line voltage and improve effective transmission capacity under normal operation,but also offer reactive power adjustment in time, damp system oscillation and improve system stability incase of fault.
Maintain the receiving-end voltage level
Since high capacity load centers lack reactive power support, it is easy to cause grid voltage dip, evencause voltage collapse. However, Static synchronous compensator (STATCOM) is capable of fast var adjustment. Therefore, the receiving-endvoltage level is greatly stabilized.
Reactive power compensation leading to high power factor and low line losses
Many types of loads need a mass of reactive power when operation, such as asynchronous motors, arcfurnaces, rolling mills and high rating rectifiers. At the same time, the upstream transformer and lineimpedance also generate reactive power, which still leading to low power factor.
For the power system, loads with lower power factor will increase the line losses, voltage drop anddeterioratevoltage quality. Additionally, reactive power will reduce efficiency of power generation,transmission and distribution. For clients, low power factor will increase production costs.
Restrain voltage fluctuation and flicker.
Voltage fluctuation and flicker are mainly caused by rapid loads variation. This rapid variation also causesthe load current fluctuation dramatically. The current variation leads to system voltage losses changingvery fast, which brings the receiving-end grid voltage flicker. The typical loads that cause voltage flicker arearc furnaces, rolling mills, electric locomotives, etc.
Static synchronous compensator (STATCOM/SVG) can offer fast reactive power regulation, which mitigate voltage fluctuation and flicker easily caused byloads variation.
Now, Static synchronous compensator (STATCOM/SVG) is the best solution to restrain voltage fluctuation and flicker compared with MCR, TCR etc.
Mitigate 3-phase unbalance.
In distribution network, there are a lot of 3-phase unbalance loads, typically like electric locomotives and arcfurnaces. At the same time, line and transformer impedance unbalances can also cause voltage unbalanceproblem. Static synchronous compensator (STATCOM) can fast compensate negative sequence current caused by unbalance loads, which ensurebalanced 3-phase grid current. Thus, it improves the power supply quality greatly.
Eliminate harmonics including Even-order, Odd-order, subharmonic and inter-harmonics(Option)
Static synchronous compensator (STATCOM/SVG) has very good harmonic suppression functions including even-order harmonic, odd-order harmonic, subharmonic and inter-harmonics, it adopted Instantaneous power theory to detect and calculate harmonic current automatically and then control PWM converter, and input compensated current into power grid which is of the right magnitude with harmonic current, but with inverse polarity.
Structure of Wanlida Static Synchronous Compensator
It mainly consists of reactor, start-up cabinet, cascade multilevel inverters cabinet and control cabinet.
Technical Advantages
Static Synchronous Compensator has the following advantages compared with traditional compensation methods:
Faster response speed
STATCOM response time: ≤5ms
Traditional static compensator response time: ≥10ms.
STATCOM can finish the conversion from rated capacitance var to rated inductance var in a very short time. This unexampled response speed makes STATCOM very suitable for impact load compensation.
Stronger voltage flicker restrain capability
SVC can restrain voltage flicker to 2:1 in maximum, but STATCOM can achieve 5:1, even higher. SVC cannot improve its capability for voltage flicker mitigation even with high capacity because of low response speed. But STATCOM responds fast. When its
capacity is increased, the capability of voltage flicker mitigation can be further improved.
Wide operation range
STATCOM can work from rated inductive power to rated capacitive power. So compared with SVC, STATCOM operation range is much wider. Furthermore, STATCOM can output rated reactive current even under low system voltage.
Multiple compensation function
STATCOM is not only functioned as fast reactive power compensator, but also harmonics and unbalance compensator according
to different demands of different clients.
Low harmonic content
STATCOM utilizes PWM, 3-level and multiple technologies. Therefore, it generates very low harmonics with compensating load
harmonics at the same time. Thus, STATCOM becomes a true multifunctional compensator.
Small volume
HV big capacitors and reactors are not necessary. STATCOM installation area is greatly smaller than that of the same capacity SVC, only 50% or even lower.
At the same time, Wanlida cooperates with the No.1 Science university in China---Tsinghua University to develop SVG, but the most important advantage for Wanlida is that we have many years experiences for Medium voltage variable frequency drives technology, because the Static Var Generator has almost structure and technology with Medium voltage variable frequency drives, in addition, Wanlida has over 21 years experiences for protection relays for reactor, capacitor etc.
Technical Features
- Provides fast smooth dynamic compensation from inductive to capacitive in reactive power, also eradicates reactive power delivery to power grid, it can meet the maximum request to compensate power factor and keep power factor close to 1.0 anytime.
- Low power loss, more better economical operation.
- Has powerful capability to support voltage and ability to continuously operate under the 1.1 times of overload.
- More fast response time and better effect for restraining flicker.
- Produce no harmonic and and compensate nearly all load harmonics without amplifying them and without generating harmonic resonance, it has more safety, stability and reliability because it is not sensitive to the system power parameters.
- Modular design. All power units are the same in structure and electric performance,thus they are interchangeable, which is easy for installation and maintenance. Redundant N+1 structure provides more higher reliability.
- Less space for installation.
Technical Specifications
Rated voltage | 6kV/10kV/22kV/27.5kV/35kV |
Rated Frequency | 50Hz (±2%) |
Rated reactive output | Capable of continuous output that ranges from inductive rated reactive to capacitive rated reactive |
Connection mode | 3phase3wires Star connection |
Response Time | ≤5ms |
Active-power loss | ≤2% of rated power |
Overload capacity | Capable of continuous operation at 1.1 times overload |
Harmonic characteristics | When it only compensates reactive power output, THDU <3%, THDI <4%; harmonic suppression rate when harmonic wave harnessing >85% |
Allowable unequalization degree of voltage | The permissible value of unbalance degree of connection-point system voltage shall not exceed 60% |
Operation indication | Touch screen, full-digitalized control |
Protection function | Power grid overvoltage, undervoltage, voltage imbalance; overload, inverter over/undervoltage, overcurrent , overtemperature; capable of automatic exiting from the power grid in case of a equipment failure |
Communication modes | Ethernet; capable of background-computer remote monitoring; reserved with RS485/232 interface |
Cooling system | Forced air cooling |
Factory Acceptance Test
We built the first-class high voltage and big capacity power electronic equipments test platform to realize Factory Acceptance Testing for whole machine before delivery.
Contact Us
- Zhuhai Wanlida Electrical Automation Co., Ltd.
- Contact nameDaniel Wu
- Phone86-756-3395623
- AddressRelay Protection Industrial Park, No.1 Technology Road, Science and Technology Innovation Coast, High-tech Zone Zhuhai,Guangdong
Active Power Filter(APF/AHF) | New Products | Static Synchronous Compensator(STATCOM/SVG) |
- monopole steel tower
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
- overhead Line fault indicator for installation methods and tools
- Flag type Overhead type Short circuit &Ground Fault Indicator
- High Voltage Cable Fault Alarm
- overhead line fault sensor
- SNV-QS High Voltage Live Display Locking Device
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- medium voltage overhead line fault current sensor and indicator
- Overhead type Short circuit & earth Fault Indicator manufacturer
- earth fault indicator distribution system
Popular Searches
Recommended Products
- PM511V16 3BSE011181R1 Control and communication Processor module
- 1C698CPE040-JP Central processor module Compatible with RS-232 and RS-485 serial communication interface
- PFCL201C 10KN Load cell Enable more complex automation and control applications
- 8237-1597 Overspeed equipment High and low voltage power input
- PM36218B-10P-1-8PH-J Magnetic element Fast response and suppression of electromagnetic interference
- GHW-12Z Radio-frequency plasma generator MKS instrument
- H92A0K9VOH00 Communication module It has a good modular design
- D136-001-008 Servo valve controller Precise position control of actuators or valves
- MVME55006E-0163 Embedded PC processor board A high-performance processor is used
- PM904F 3BDH001002R0001 Processor module Ability to quickly execute various control logics and algorithms
- MVME2400 VME processor module Performance of the PowerPlus II architecture
- FC-QPP-0001 Quad-core processor package module Four bus drivers are used to drive the IO chassis
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Daniel Wu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-