Home > Instruments & Meters > Meter for Liquid & Gas > Thermometer & Hygrometer > Thermocouple Calibrator,precision Calibrator,handheld Calibrator,0.05% Accuracy

Thermocouple Calibrator,precision Calibrator,handheld Calibrator,0.05% Accuracy

Thermocouple Calibrator,precision Calibrator,handheld Calibrator,0.05% Accuracy photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Place of Origin:
Fujian, China
Model Number:
ETX-1814
Usage:
Industrial
Payment & Shipping
Payment Methods:
Port of Shipment:
xiamen
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Fujian, China
Model Number ETX-1814
Usage Industrial
Theory Thermocouple Thermometer
Accuracy 0.05%

Specifications

Output of DC mV and simulation of thermocouple output
Voltage, DC mV and thermocouple measurement

Features and Benefits

  • Output of DC mV and simulation of thermocouple output.
  • Voltage, DC mV and thermocouple measurement.
  • Automatic and manual cold end temperature compensation for TC.
  • Manual stepping, automatic stepping, 0~100% phase step and slope output

Summary of Source and Measure Functions

Function

Measure

Source

DC V

0~30 V

Not available

DC mV

0~100 mV

0~100 mV

Thermocouple

E,J,K,T,B,R,S,N

E,J,K,T,B,R,S,N

Others

Stepping output, ramp, phase step output, user-defined range

Specifications

Specifications are based on a one year calibration cycle and apply from +18°C to +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.

1,DC Voltage Measurement

Range

Maximum measurement range

Resolution

Accuracy (% of reading + Counts)

ETX-1814

ETX-2014

30V

0V~31V

0.001V

0.05+2

0.02+2

100mV

-15mV~125mV

0.01mV

0.05+2

0.02+2

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

Input resistance: >1MΩ.

2,Thermocouple

Graduation

Range

Resolution

Accuracy (Ω)

ETX-1814

ETX-2014

J

-200°C~0°C

0°C~1200°C

0.1°C

1.5°C

1.0°C

1.0°C

0.7°C

K

-200°C~0°C

0°C~1370°C

0.1°C

1.8°C

1.2°C

1.2°C

0.8°C

T

-200°C~0°C

0°C~400°C

0.1°C

1.8°C

1.2°C

1.2°C

0.8°C

E

-200°C~0°C

0°C~950°C

0.1°C

1.5°C

1.0°C

0.9°C

0.7°C

R

-20°C~0°C

0°C~500°C

500°C~1750°C

1°C

4°C

2.5°C

2°C

2.5°C

1.8°C

1.4°C

S

-20°C~0°C

0°C~500°C

500°C~1750°C

1°C

4°C

2.5°C

2°C

2.5°C

1.8°C

1.5°C

B

600°C~800°C

800°C~1000°C

1000°C~1800°C

1°C

3.5°C

2.5°C

2°C

2.2°C

1.8°C

1.4°C

N

-200°C~0°C

0°C~1300°C

0.1°C

2.0°C

1.2°C

1.5°C

0.9°C

Errors of cold-junction compensation are not included in the table.

Accuracy of cold-junction compensation: 1.5°C