Phase Single Phase
Protection Other, Lighting/Over voltage/Short circuit/Overload/Over temperature
Output Voltage 230/115VAC
Type Other, On-line, Low frequency
Application Telecommunications

UPS: Low Frequence Online UPS

Product Description

PQZ series UPS use the advanced PWM and IGBT inverted technology, capable of precisely controlling all kinds of operation parameters of the UPS, therefore the UPS can provide a high quality and reliable AC power source for your precise equipments. With their unique AVR design that expands the input range, the PQZ series UPS are very suitable for harsh environment, reduce battery charge/discharge times, thus extend battery life. Besides, the long backup UPS with large built-in charger (10A) can rapidly recharge external battery so as to provide perfect protection for long blackout.

PQZ series UPS utilize microprocessor control to replace traditional analog or digital components in its control board. The design not only increases the MTBF but also provide a precise and reliable output. Additional feature with the microprocessor control is to communicate with laptop/equipment that is connected to the UPS via RS-232/RS-485 interface. By using the monitoring software, users can easily monitor UPS and can schedule to turn on/off UPS. Up to 3996 events can be recorded and saved in the UPS.

With proven field experience all over the world including some harsh environment area, the PQZ series UPS provide an optimum choice for complete protection solution from micro computers to large scaled computers, from communication systems to industrial automatic control equipments.

Technical specifications:

PQZ2K~20KSingle phase 1 in and 1 out

Model:

PQZ1K

PQZ2K

PQZ3K

PQZ6K

PQZ10K

PQZ15K

PQZ20K

Capacity (VA/W)

1K/0.8K

2K/1.6K

3K/2.4K

6K/4.8K

10K/8K

15K/12K

20K/16K

Input Voltage

Single phase with two Lines+ground wire ,230V±25%

Noise

≤52dB(distance 1m)

≤60dB(distance 1m)

Size

(D×W×H,mm)

530×264×592

630×343×700

Weight (Kg) (w/o battery)

30

65

70

80

145

160

180

Input

Frequency

50Hz /60Hz ± 10%

Power factor

≥0.95

Output

Voltage

{0>

22220V± 0.5%<}0{><0}

 

Voltage regulation

Stable ±1%,dynamic ±2%, (<20ms for 0-100%load change)

Frequency stabilization

50Hz /60Hz ± 0.5% (Battery Mode)

Frequency slow rate

< 1Hz / second

Transient response

± 0.4% (100% instant load fluctuation)

THD

<3% for linear load; <5% for non-linear load

Overload

110%~150% for 10seconds; >150% for 1second

Wave form

True sine wave

Efficiency

Input AC to output AC

> 90%

Transfer time

AC mains fails and/or restores

0second

 UPS to BYPASS

< 4 ms

Battery

Voltage

192V

Charge time

8 hrs recharge to 90% capacity

Alarm

Battery discharge

Beeps once every 4 seconds when battery discharge

Beeps once every 1 second when battery low.

Beeps continuously when battery discharge stop

UPS fault

Beeps continuously

Protection

Battery low

Auto shutdown when battery low without fuse protection.

Overload

110150% overload for 10 seconds, then auto jumps to BYPASS; Auto resumes when overload removed

Over temperature

Auto jumps to BYPASS when UPS internal temperature >85°C

Output short circuit

Current limits, auto shutdown, no fuse switch protection.

UPS fault

Auto jumps to BYPASS

Noise Filter<0}

10~10KHz at 40 db; 100KHz~100MHz at 70 db

Display

LCD

Input and output voltage, frequency; battery voltage and output power (%), etc

LED (BLV)

LED (BLV) turns on when battery voltage low.

Ambient

Temperature

0~40

Relative humidity

10%~90% (No condensation)

Altitude

1500 meters

 

Production Line

 Online Low Frequency UPS (PQZ Series 6~20K)(1 phase 1 in/1 out)

Certifications

 Online Low Frequency UPS (PQZ Series 6~20K)(1 phase 1 in/1 out)

Packaging & Shipping

 Online Low Frequency UPS (PQZ Series 6~20K)(1 phase 1 in/1 out)

Why choose us

1.Excellent quality

 

2.Favoured price

 

3.Professional after-sales service&local training guide on site

 

4.Experienced workers team

 

5.Online UPS,line interactive UPS,off line UPS,inverters,rectifiers Leading supplier from China,ISO certificated

 

6.Customized

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2007
Factory Size
1,000-3,000 square meters
Total Employees
101 - 200 People