30KVA Online UPS
30KVA online UPS
30KVA online UPS
Technical data sheet:
QZ 6K3~60K3 Three-ins/One out | |||||||||
Mode: |
PQZ6K3 |
PQZ10K3 |
PQZ15K3 |
PQZ20K3 |
PQZ30K3 |
PQZ40K3 |
PQZ50K3 |
PQZ60K3 |
|
Capacity (VA/W) |
6K/4.8K |
10K/8K |
15K/12K |
20K/16K |
30K/24K |
40K/32K |
50K/40 |
60K/48K |
|
Input Voltage |
Three phase with four Lines+ground wire,380V±25% |
||||||||
Noise |
≤60dB(distance 1m) |
≤65dB(distance 1m) |
|||||||
|
Size (D×W×H,mm) |
620×343×995 |
650×700×1510 |
|||||||
Weight(Kg) (w/o battery) |
130 |
165 |
180 |
220 |
400 |
450 |
530 |
620 |
|
| Common parameters | |||||||||
Input |
Frequency |
50Hz /60Hz ± 10% |
|||||||
Power factor |
≥0.95 |
||||||||
Output |
Voltage |
{0> 22220V± 0.5%<}0{><0}
|
|||||||
Voltage regulation |
Stable ±1%,dynamic ±2%, (<20ms for 0-100%load change) |
||||||||
Frequency stabilization |
50Hz /60Hz ± 0.5% (Battery Mode) |
||||||||
Frequency slow rate |
< 1Hz / second |
||||||||
Transient response |
± 0.4% (100% instant load fluctuation) |
||||||||
THD |
<3% for linear load; <5% for non-linear load |
||||||||
Overload |
110%~150% for 10seconds; >150% for 1second |
||||||||
Wave form |
True sine wave |
||||||||
Efficiency |
Input AC to output AC |
> 90% |
|||||||
Transfer time |
AC mains fails and/or restores |
0second |
|||||||
UPS to BYPASS |
< 4 ms |
||||||||
Battery |
Voltage |
192V |
|||||||
Charge time |
8 hrs recharge to 90% capacity |
||||||||
Alarm |
Battery discharge |
Beeps once every 4 seconds when battery discharge |
|||||||
Beeps once every 1 second when battery low. | |||||||||
Beeps continuously when battery discharge stop | |||||||||
UPS fault |
Beeps continuously |
||||||||
Protection |
Battery low |
Auto shutdown when battery low without fuse protection. |
|||||||
Overload |
110∼150% overload for 10 seconds, then auto jumps to BYPASS; Auto resumes when overload removed |
||||||||
Over temperature |
Auto jumps to BYPASS when UPS internal temperature >85°C |
||||||||
Output short circuit |
Current limits, auto shutdown, no fuse switch protection. |
||||||||
UPS fault |
Auto jumps to BYPASS |
||||||||
Noise Filter<0} |
10~10KHz at 40 db; 100KHz~100MHz at 70 db |
||||||||
Display |
LCD |
Input and output voltage, frequency; battery voltage and output power (%), etc |
|||||||
LED (BLV) |
LED (BLV) turns on when battery voltage low. |
||||||||
Ambient |
Temperature |
0~40 |
|||||||
Relative humidity |
10%~90% (No condensation) |
||||||||
Altitude |
1500 meters |
||||||||
1.Excellent quality
2.Favoured price
3.Professional after-sales service&local training guide on site
4.Experienced workers team
5.Online UPS,line interactive UPS and Inverters leading mnufacturer in China,ISO certificated
6.Customized
Send Inquiry to This Supplier
You May Also Like
-
Eaton 9px6ki 9px 6kVA 1: 1 UPS Online Rack/Tower Online UPSNegotiableMOQ: 1 Piece
-
Sales Promotion High Quality 110V 220 V Single Three Phase Uninterruptible Power Supply Online UPS SystemNegotiableMOQ: 1
-
UPS / Uninterruptible Power SupplyUS$ 137 - 792MOQ: 1 Piece
-
AVR Intelligent Voltage RegulatorUS$ 300 - 5,000MOQ: 1 Piece
-
Online UPSNegotiableMOQ: 10 Sets
-
12V120Ah LiFePO4 Smart Battery for UPSNegotiableMOQ: 1 Set
-
Socomec UPS Uninterrupted Power SupplyNegotiableMOQ: 1
-
UPS Express to BANGLADESH From ShenzhenUS$ 1 - 20MOQ: 1 Kilogram
-
2016 Canton Fair Gel Battery 12v 150ahUS$ 155.00 - 160.00MOQ: 50 Pieces
-
EverExceed 1-400KVA 3 Phase Low Frequency Online UPS, GBT Input Rectifier PowrNX For TelecommucationUS$ 5,311 - 42,295MOQ: 1 Piece