Home > Electrical & Electronics > Optical Fiber, Cable & Wire > Electric Wire & Cable > Cold Shrink Tube for Cell Tower Sealing Kits

Cold Shrink Tube for Cell Tower Sealing Kits

Cold Shrink Tube for Cell Tower Sealing Kits photo-1
Cold Shrink Tube for Cell Tower Sealing Kits photo-2
Cold Shrink Tube for Cell Tower Sealing Kits photo-3
Cold Shrink Tube for Cell Tower Sealing Kits photo-4
US$ 10 - 400 MOQ: 1 Set
Key Specifications
Get Latest Price
Place of Origin:
Shandong, China
Brand Name:
ASUNT
Model Number:
QX-NL-1603
Payment & Shipping
Payment Methods:
Port of Shipment:
qingdao port
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Shandong, China
Brand Name ASUNT
Model Number QX-NL-1603
Conductor Material Copper
Insulation Material Rubber
Jacket Rubber
Number of Conductors 1-6
Application 1kv-35kv

  cold shrink tube for cell tower sealing kits

Description:

 

Cold shrink tubing is a fast and easy way to weatherproof a connection.  Simply position the pre-expanded tubing over the connection that you are protecting and

pull the rip cord. The tubing compresses to form a weatherproof seal.

 

 

Type and Specification:

 

  

Product type

Suitable cable section  mm2

Product type

Suitable cable section  mm2

10KV single core indoor use

20-50

35KV single core indoor use

50-95

70-150

120-185

185-400

240-400

10KV single core outdoor use

20-50

35KV single core outdoor use

50-95

70-150

120-185

185-400

240-400

10KV three core indoor use

20-50

10KV three core indoor use

50-95

70-150

120-185

185-400

240-400

10KV three core outdoor use

20-50

10KV three core outdoor use

50-95

70-150

120-185

185-400

240-400

 

 

 

Tech Data:

 

 

 

No. Test Project Standard Requirements Conclusion
1 Power Frequency Voltage 39KV 5min No Flashover and No Breakdown pass
2 Partial Discharge Under 15KV, Discharge volume10pc pass
3 Impulse Voltage Test Under 95KV, ±10times No flashover and No Breakdown
4 Constant Voltage load Cycle(in air) The conductor applied voltage 23KV, and heated to (95-100°C). In which the temperature stability 2h,cooling 3h, a total of 3cycles. Not flashover and assessed by the following test result
5 Constant load Cycle test The conductor applied voltage 23KV, and heated to (95-100°C). In which the temperature stability 2h,cooling 3h, a total of 6cycles. Not flashover and assessed by the following test result
6 Thermal Stability Test Under 23KA, Short circuit 2 times, No visible damage. pass
7 Dynamic Stability Test Under 81KA, Short circuit 1 time, No visible damage pass
8 AC Withstand Voltage 23KV, 15min No flashover and No Breakdown
9 Tide Temperature Test 11KV, 300h pass
10 Salt Spray Test 11KV, 1000h pass

 

 cold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kits

 cold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kits

cold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kitscold shrink tube for cell tower sealing kits

 