AAC Conductor
Specifications
AAC conductor1. ISO9001, ISO14001, CCC
2.one of China's biggest cable manufactory
1. The applications of AAC conductor/All Aluminum Stranded Bare Conductor
| Conductor(AAC and ACSR) have been widely used in power transmission lines with various voltage levels, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost large transmission capacity. And they are also suitable for laying across rivers valleys and the places where special geographical features exist. |
2. AAC conductor/All Aluminum Stranded Bare Conductor 's Service Performance
| (1). The permissible long-time operating temperature for aerial conductor is 70oC. (2). Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area, the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power. (3). When connecting conductors, the conductor beside the connecting tube cant be prominent. Otherwise, the force on the operating conductors will be unbalanced. After connectors are install, the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion. (4). Under installaion, the arc downing stress of all the conductors should be the same. With in the permissible distance of crossing buildings or dropping to the ground, the stress can be 10-15% higher than regular stress. |
3. The Performance about AAC conductor/All Aluminum Stranded Bare Conductor
|
(1). The electrical performance of AAC and ACSR is indicated in DCΩ/km(20oC). The resistivity of the hard aluminum wire for Strandeded wires is not greater than 28.264 nΩ. m of international standard value. |
4. AAC conductor/All Aluminum Stranded Bare Conductor ‘s Material Standard
(1). The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889: 1987).
(2). The zinc coated steel wire used for ACSR conforms to IEC 60888: 1987.
(3). Production can be arranged according to customers requirements for material standard, etc.
5. The following tables showing the properties of AAC conductor/All Aluminum Stranded Bare Conductor
5.The following tables showing the properties of AAC conductor/All Aluminum Stranded Bare Conductor
Nominal area (sqmm) |
Stranded and Wire diameter |
Calculated Section Area |
Approx. Overall Diameter |
D.C. Resistance Not Exceed(Ohm/KM) |
Calculated breaking load(kg/km) |
Calculated weight(kg/km) |
Delivery length (meter) |
16 |
7/1.70 |
15.89 |
5.10 |
1.802 |
2840 |
43.5 |
4000 |
50 |
7/3.00 |
49.48 |
9.00 |
0.5786 |
7930 |
135.5 |
1500 |
120 |
19/2.85 |
121.21 |
14.25 |
0.2373 |
19420 |
333.5 |
1500 |
400 |
37/3.70 |
397.83 |
25.90 |
0.07247 |
61150 |
1097 |
1000 |
Send Inquiry to This Supplier
You May Also Like
-
Sick YF8U14-050VA3XLEAX - Sensor/actuator CableNegotiableMOQ: 1 Piece
-
IEC Standard High Quality Enameled Aluminum Flat Magnet Wire Winding Enameled Aluminum WireUS$ 4.85 - 4.89MOQ: 500 Kilograms
-
Pesticide Spraying Machine Wire Harnrss Tractors and Agricultural Machinery Cable AssemblyNegotiableMOQ: 1 Unit
-
4/8/16/32CH Channels Multi Cable With Wheel/6 UTP Multipair CableUS$ 500 - 800MOQ: 10 Pieces
-
Electronic Wire 450/750vUS$ 1 - 10000MOQ: 1 Piece
-
Self-Regulating Heat Tracing Cable for Safe and Energy-Efficient Process HeatingNegotiableMOQ: 100 Meters
-
Advanced Self-Regulating Heating Cable for Freeze Protection & Temperature MaintenanceUS$ 0.98MOQ: 10 Meters
-
BVR Flexible CableNegotiableMOQ: 5000 Meters
-
Sports and Gym Equipment Silicone Grip Pipe Wrapping TapeNegotiableMOQ: 1 Roll
-
Electric Wire CableNegotiableMOQ: 2700 Meters