Home > Products > Auto Switch > Dual power automatic transfer switch
Dual power automatic transfer switch
- 6000 Set / Sets per Month
- Guangzhou Shenzhen
- T/T L/C D/P D/A Credit Card PayPal
Product Details
Place of Origin: | Guangdong, China | Brand Name: | CGZ | Model Number: | GZQ1 |
Max. Current: | 63A | Max. Voltage: | 690V |
Product Description
◊◊ Dual power automatic transfer switch ◊◊
1. Long lifespan
2. High impact resistance material
3. Easy to install and wiring
4. Autumatic transfer switch
5. Competitive price
Dual power automatic transfer switch
1.Application
GZQ1 series dual power automatic transfer switch(ATS) is terminal type automatic transfer device. It’s suitable for 3 phases 4 wires dual power grid with AC 50/60Hz, rated voltage 400V/230V and rated current up to 63A. When one power goes wrong (only test normal Phase A voltage and reserve Phase A voltage, only test loss voltage or loss phase), it will automatic connect one or several load circuits from one power to the other power automatically, to ensure normal power supply of load circuits.
The automatic transfer switch conforms to IEC60947-6-1 and GB/T14048.11
2.Normal conditions for operation & installation
Environmental Temperature Condition:-25°C ~+60°C
Installation site is not more than 2000 meters above sea level.
Pollution Level: Grade 3
Installation Category: 3
Vertical installation or horizontal installation
3.Main Parameter
Rated Current Ie A | 6,10,16,20,25,32,40 | 50, 63 |
Electrical Appliances Class | CB | |
Use Category | AC~33B | |
Tripping Current | 5~10In (Type C), 10~15In (Type D), | |
Rated voltage Ue | 220V (2P),380V (3P or 4P) | |
Rated frequency | 50/60Hz | |
Rated short circuit connecting ability Icm (Peak) | 9.18KA | 6.615KA |
Rated short circuit breaking ability Icn (effective value) | 6KA | 4.5KA |
4.Founction introduction
Function | Basic type | Multifunction type | Full-function type |
Manual moda | yes | yes | yes |
Automatic moda | yes | yes | yes |
Motor protection function | yes | yes | yes |
Main contact working position(performing circuit breaker) |
|
|
|
Frequency-used power supply closed | yes | yes | yes |
Reserve power supply closed | yes | yes | yes |
Double portion | yes | yes | yes |
Automatic control | |||
Frequency-used power supply indication | yes | yes | yes |
Reserve monitoring power supply | yes | yes | yes |
Automatic connection and automatic changeover | yes | yes | yes |
Automatic connection and non-automatic changeover | no | yes | yes |
Reserve for each other | yes | yes | yes |
Power grid-power grid | yes | yes | yes |
Power grid-generate electricity | no | yes | yes |
Phase break instaneous protection | yes | yes | yes |
Under-voltage protection 150-210V | adjustable | adjustable | adjustable |
Over-voltage protection 230-280V | yes | yes | yes |
Voltage loss protection 30%Ue | yes | yes | yes |
Fire control function | no | yes | yes |
Changeover time delay 0-100s continuous adjustable | yes | yes | yes |
Returning time delay 0-100s continuous adjustable | yes | yes | yes |
Frequency protection | no | no | yes |
Communication function | no | no | yes |
Indication | |||
Closed/open/double portion indication | yes | yes | yes |
Frequent-use power supply indication | yes | yes | yes |
Reserve power supply indication | yes | yes | yes |
Fault tripping indication | yes | yes | yes |
Parameter setting indication | yes | yes | yes |
Voltage real time indication | yes | yes | yes |
Normal three phase voltage protection | three phase | three phase | three phase |
Reserve three phase voltage protection | three phase | three phase | three phase |
5.Product photos
6.Installation & wiring
ATS can be installed in power control cabinet directly. Users can wire after ATS installation (refer to design and use). As per current value use suitable conductor to connect the mains side (top terminal) and load side (bottom terminal) of MCB of normal electric power and standby electric power. In-phase parallel connection at load side, and ensure the phase sequence of normal electric power and standby electric power must be accordant (Wire as per A,B,C,N sequence). For 3 poles ATS should add one conductor with section not less than 0.3mm2 to connect theneuter line of power supply correctly, thus ATS can work properly. For 4 poles or 2 poles ATS, N pole of normal electric power and standby electric power should be connected to N pole of MCB respectively. In addition, when install ATS please ground reliably at grounding mark.
Auxiliary terminal is active contact signal, only used for external connection with indicator to display Off state, should be connected to the indicator directly. Can’t put in power at auxiliary terminal (but for 3 poles ATS should add one conductor with section not less than 0.3mm2 to connect theneuter line of power supply and the terminals of neuter line on ATS auxiliary terminal. Otherwise ATS can’t work properly.)
7.Use
1) Normal use, please set the switch of controller at Automatic Function. Under Auto working the controller of ATS monitor normal electric power and standby electric power and display running status of ATS. When Normal power cut, novoltage, failure, ATS will transfer load automatically from normal power to standby power. If normal power get right, ATS will transfer load automatically from standby power to normal power. The luminous diode on switch panel indicate switch off situation.
2) If you don’t adopt automatic transfer or need other manual operation please set the controller at manual. Under manual operation the controller stop work, and manual operation can make the breaker on off, and the switch doesn’t transfer automatically.
3) When ATS is short circuit or over load, The MCB of ATS will protect tripping. If power display normally the handle of MCB is switching on. If the MCB has protected tripping users should set at manual and operate the switch to dual separating brake by hand, and check the reason of trip. After trouble clearing please set the controller at auto again to operate.
4) When ATS transfer to auto from manual, if normal and standby power are normal ATS will prior connect normal power to load (even if load connected standby power ago)
8.Matters need to attention
When users test or operate please follow relative rules and pay attention to the following matters to ensure use our ATS correctly.
1)Neutral conductor N can’t be connected in wrong way, must connect reliably, otherwise ATS can’t operate properly, even burn controller and motor.
2)The protective grounding of ATS must be connected reliably to ensure safety.
3)Detection sampling signal for controller work power and main power supply is taken from Power supply side of main circuit, and work power of auxiliary connection terminal used for connect indicator is taken from main circuit, so can’t have voltage test between spare terminals (unless dismantle the secondary wires). Can have power frequency voltage test between main circuit and shell or between secondary auxiliary terminals and shell.
9.Simple troubleshooting
When users find fault can request professional to test and deal with. Keep Away for Safety when operate. Or contact our Specialized Service Departments.
1) Double Power are both switched on, but ATS can’t transfer automatically
1. Check Auto/manual should be in automatic position.
2. Check if incoming line is correct or not, if phase sequence is accordance or not, and wiring is solid and reliable or not.
3. Check if the fuse is burned on not.
2) Double power are both switched on, ATS standby power is switching on.
1. Check if normal power incoming line has voltage or not.
2. Check Commonly used insurance
3. Check if external light is connected in wrong way or not.
10.Defects liability period
On the premise of that users comply with the prescriptive maintenance and usage, such products would have a defects liability period of 3 years.
11.Company profile:
12.Professonal production:
Contact us:
How to buy our products?
Send your inquiry through our alibaba website,we will reply you at the soonest time;
Our service:
1. OEM Experiences above 12 Years in this field.
2. Reply your enquiry in 24 working hours.
3. Experienced staffs answer all your questions in professional and fluent English.
4. Customized design is available. OEM & ODM are welcome.
5. Exclusive and unique solution can be provided to our customer by our well-trained and professional engineers and staffs.
6. Special discount and protection of sales area provided to your distributor.
Send your inquiry details in the below, click "Send" !! Thank you!
Contact Us
- Foshan Guangzhu Electrical Co., Ltd.
- Contact nameJACKIE QIAN
- Phone86-757-82826898
- AddressNO.54 LECHENG FIRST ROAD, LE'AN, GUANGFO ROAD, FOSHAN CITY, GUANGDONG PROVINCE, CHINA Foshan,Guangdong
- P+F Safety Arrier KFD0-RO-EX2 P+F KCD2
- M3050 ac sensor current detection switch 220v alarm module transformer adjustable ac current normally open/near
- Twisted Reed Switch With Bending Legs/Cutting Leads
- High Power 21mm Reed Switch RI-48/ORD229 For 220V Switch Circuit
- Normally Open/Normally Closed/Changeover Contact Reed Switch SMD/THT/Bending
- Normally Open Magnetic Contact Reed Switch 7mm/10mm/14mm/20mm/50mm
- 14mm Glass Tube Magnetic Contact Reed Switch,1500pcs/White Box
- Auxiliary switch circuit breaker rail transportation high voltage switch pure silver contact
- 50mm High Voltage Reed Switch MKA-50202 AT40-50/AT50-60/AT60-70/AT70-80/AT80-90
- 27mm Change Over/Normally Closed Reed Switch MKC-27103 AT50-60/60-70/70-80
- 14mm Dry Contact Reed Switch MKA-14103 AT10-15/AT15-20/AT20-25/AT25-30/AT30-35
- 10mm Reed Switch MKA-10110 AT10-15/AT15-20/AT20-25/AT25-30/AT30-35
- 7mm Glass Hermetic Reed Switch MKA-07101 AT10-15/MKA07101 10-15AT
- Replacing ALPS SSCM110100 Domestic Detection Switch Camera Switch Bidirectional Sensing Travel Switch
- Japan ALPS Alps Detection Switch SPVQ820602 Waterproof Car Switch Hood Switch
- Banner S18-2VPFF200-Q8
- FA (F10) fast tap auxiliary switch High voltage switch Circuit breaker Slow speed mechanism auxiliary switch
- NEW WORK 1-GANG PVC BOX-18 CU. IN
Popular Searches
Recommended Products
- FOXBORO FBMSVH Control card module
- FOXBORO FBMSVL Multi port serial card
- ABB XVC770BE102 3BHE021083R0102 Thermal dispersion technology flow meter
- ABB XVC770AE 3BHE006414R0001 Servo Driver
- ABB PFEA113-65 3BSE050092R65 Dual expansion port module
- ABB LTC391AE01 HIEE401782R0001 connecting module
- ABB DSAI 130A 3BSE018292R1 Digital input/output module
- GE SR489-P5-HI-A20-E Protection Relay
- VIBRO-METER VM600 RPS6U 200-582-500-013 Vibration monitoring and control system
- HONEYWELL SPS5710 51199929-100 Power supply module
- GE IS210BPPBH2CAA Digital expansion module
- GE IS200TSVCH2AED MRP246517 Digital I/O module
Find Similar Products By Category
- Electrical Equipment & Supplies > Switches > Other Switches
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
JACKIE QIAN
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-