Good Cooling Effect Water Tower (JL)
Specifications
Good Cooling Effect Water Tower1. Max. Tem. Resistance is 95 deg.
2. Good cooling effect.
3. Energy saving.
Good Cooling Effect Water Tower
Technical Parameter:
Content | Technical Parameter |
Design Condition |
|
Cooling capacity (MW) | 100000Kcal/h |
Inlet/Outlet Temperature | <55°C |
Flow of Circuiting water | 10-30T/H |
Quality of spraying water | Clean water/urban waterways |
Tower Body |
|
Length (mm) | 3000 |
Width (mm) | 1000 |
Height (mm) | 1950 |
N.W./Operation Weight(kg) | 840/1860 |
Pipe Size | |
Inlet size | DN65 |
Outlet Size | DN65 |
Overflow Pipe | DN15 |
Drain Pipe | DN15 |
Filling water pipe | DN15 |
Cooling Fan |
|
Air capacity m3/h | 24000 |
Diameter /Number of fan | 1200mm x 2 |
Power (kw) | 1.5 |
Motors | TEFC |
Power Supply | 380V/3P/50HZ |
Insulation Grade | F |
Configuration and introduction of Closed Cooling Tower
1. Cooling Principle
Main host of cooling tower consists of shell, heat exchange, fan blower, spray pump, water eliminator, water basin and pipe valves etc. The process fluid is circulated through the coil of the closed circuit cooler. Heat from the process fluid is dissipated through the coil tubes to the water cascading downward over the tubes. At the same time, air is drawn in through the air inlet louvers at the base of cooler and travels upward over the coil opposite the water flow. A small portion of water is evaporated which removes the heat. The warm moist air is discharged to the atmosphere. The remaining water falls to the sump at the bottom of the cooler where it is recirculated by the pump up through the water distribution system and back down over the coils.
2.Structure Principle Drawing:


Send Inquiry to This Supplier
You May Also Like
-
Japan Saginomiya ATX-71110DHS/DUS/DHG ATX Series Thermal Expansion ValveUS$ 10 - 15MOQ: 1 Piece
-
Sanhua Parts DPF-TS/S Series Electronic Expansion ValveDPF(S03)4.0C-01 PQ-M03012-000012US$ 70 - 300MOQ: 1 Piece
-
SPRLAN Thermal Expansion Valve FBVE-6CP100 6 Cold Stamping (1/2*5/8*1/4 76CMUS$ 70 - 300MOQ: 1 Piece
-
SPRLAN Thermal Expansion Valve FBVE-6CP100 6 Cold Stamping(5/8*7/8*1/4)152CMMUS$ 70 - 300MOQ: 1 Piece
-
SPRLAN Thermal Expansion Valve FBVE-3-Z FBVE-1.5-Z Refrigeration AccessorieUS$ 70 - 300MOQ: 1 Piece
-
SPRLAN S.P.R.L.AN Thermal Expansion Valve FJE-1-C 1 Cold Hammer, Refrigeration Unit Spare Parts Air ConditioningUS$ 70 - 300MOQ: 1 Piece
-
SECOP Refrigerator Air Conditioner Refrigeration Compressor SC21CNX.2US$ 70 - 300MOQ: 1 Piece
-
Castel Valve Solenoid Valve 1078/5 1078/4A6 Refrigerate PartsUS$ 70 - 300MOQ: 1 Piece
-
DunAn Shield Electromagnetic Valve Refrigeration Equipment FDF3-1002 FDF10-1002 FDF6-102US$ 300 - 8000MOQ: 1 Piece
-
DunAn Shield Electromagnetic Valve Refrigeration Equipment Air Conditioning Solenoid Valve FDF3-1002 FDF15-1002 FDF10-1002US$ 300 - 8000MOQ: 1 Piece

