Acuvim II Series Energy Monitor
Specifications
1.Acuvim II Eelectric meters2.TOU, 4 Tariffs, 12 Seasons
3.Web Server and Email Sending
4.Revenue Grade with Data Logging
The Acuvim IIE is Energy Monitor by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution systems. Some of the features and electric power parameters available on the ultra-compact Acuvim IIE are:
- True-RMS Measuring Parameter
- ANSI C12.20(0.2 Class) and IEC 62053-22 (0.2S Class)
- Power Quality Analysis
- Over/Under Limit Alarm
- Multi Communication Ports (Eg: Ethernet, RS485)
- Web Server and Email Sending
- Switch Status Monitoring
- Remote Switch Controlling
- Measure Individual Harmonics from 2nd to 63rd
- Module Design
- Data-Logging
Metering
- Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
- Current I1, I2, I3, In, Iavg
- Power P1, P2, P3, Psum
- Reactive Power Q1, Q2, Q3, Qsum
- Apparent Power S1, S2, S3, Ssum
- Frequency F
- Power Factor PF1, PF2, PF3, PF
- Energy Ep_imp, Ep_exp, Ep_total, Ep_net
- Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
- Apparent Energy Es
- Demand Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3
- Load Features
- Four Quadrant Powers
Monitoring
- Power Quality
- Voltage Harmonics 2nd to 63rd and THD
- Current Harmonics 2nd to 63rd and THD
- Voltage Crest Factor
- THFF (TIF)
- Current K Factor
- Voltage Unbalance Factor U_unbl
- Current Unbalance Factor I_unbl
- Max/Min Statistics with Time Stamps
Fexible I/O module
The E-moduleR technique was adopted for its flexibility and easy expansion of the I/O function of Acuvim IIE. A maximum of 3 modules can be used for one meter. Digital input, Digital output, pulse output, relay output, analog input and analog output are provided by I/O option module.
Alarms
The limits of the less than 9 indicated parameters can be set with a specified, time interval. If any input of the 9 indicated parameters is over or under its setting limit with persisting time over specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 9 indicated parameters can be any of the following 34 ones.
F, V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg, I1, I2, I3, Iavg, In, P1, P2, P3, Psum, Q1, Q2, Q3, Qsum, S1, S2, S3, Ssum, PF1, PF2, PF3, PF, U_unbl, I_unbl, Dmd_P, Dmd_Q, Dmd_S
Communication
- RS485, Industry standard ModbusRprotocol
- Module Option: Ethernet module, Profbus-DP module
- Dual RS485 communication ports
- RS-485 (Standard): MODBUS RTU Protocol, 2-wire connection, Up to 38400 baud rate
- Ethernet (Optional): 10M/100M BaseT, MODBUSR TCP/IP Protocol, Data Browsing through HTTP, Sending e-mail automatically
- PROFI-BUS (Optional): PROFIBUS-DP/V0 Protocol; Work as PROFIBUS slave, baud rate adaptive, up to 12M; Typical input bytes: 32, typical output bytes: 32; PROFIBUS standard according to EN 50170 vol.2
Data_logging
The Acuvim IIE, model offers 4MB of onboard data logging memory to be used for historical trending. There are 3 assignable historical logs where the majority of the metering parameters can be recorded. A real time clock allows for any logged events to be accurately time stamped.
Display
Clear and large character LCD Screen display with white back light Wide environmental temperature endurance
Display Load percentage, 4 quadrants power and load nature
Outline
Small Size 96×96 DIN or 4'' ANSI Round
Certificate
- CE
- UL
Send Inquiry to This Supplier
You May Also Like
-
RS485 Power Meter From AccuenergyNegotiableMOQ: 1 Piece
-
LCD Display Power Meter - Acuvim II SeriesNegotiableMOQ: 1 Piece
-
Acuvim II Series Electric Meter MeasurementNegotiableMOQ: 1 Piece
-
Acuvim II Series Modbus Electric MeterNegotiableMOQ: 1 Piece
-
Acuvim II Series Intelligent Digital MeterNegotiableMOQ: 1 Piece
-
Acuvim II Series Intelligent MeterNegotiableMOQ: 1 Piece
-
Acuvim II Series Digital Electric MeterNegotiableMOQ: 1 Piece
-
Acuvim II Series Intelligent Electric MeterNegotiableMOQ: 1 Piece
-
Acuvim II Series Din Rail Electric MeterNegotiableMOQ: 2 Pieces
-
Acuvim II Series Quality Digital Kwh MeterNegotiableMOQ: 2 Pieces