Home > Instruments & Meters > Weighing & Measuring Apparatus > Gauge > Elcometer With Eddy Current Testing Function for Auto Car Paint Coating

Elcometer With Eddy Current Testing Function for Auto Car Paint Coating

Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-1
Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-2
Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-3
Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-4
Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-5
Elcometer With Eddy Current Testing Function for Auto Car Paint Coating photo-6
US$ 70 - 300 MOQ: 10 Sets
Key Specifications
Get Latest Price
Place of Origin:
China
Brand Name:
PULANI
Model Number:
CT2013FN- UPDATE
Payment & Shipping
Payment Methods:
Port of Shipment:
Ningbo/Shanghai
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin China
Brand Name PULANI
Model Number CT2013FN- UPDATE
Product Description

 Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

1 Product Introduction

The coating thickness measuring instrument uses a dual function measurement method, it can automatically identify magnetic and non-magnetic substrate, and then use the appropriate test method, it can measure the  thickness of the non-magnetic coating  (such as aluminum, copper, enamel, rubber, paint, etc) on magnetic metal substrates (such as steel, iron , alloy and Hard magnetic steel).And the non-conductive coating thickness on a non-magnetic metal substrate.

The instrument has advantages of high detection accuracy, reliable and easy to maintain, good stability, simple operation, etc. It can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and testing fields.

 

Features Introduction:

l  More widely measuring range : 0-1700um

l  Automatic identification substrate material and display it on the LCD

l  Big screen, and a variety of colors back-light optional

l  Button is simple, easy to operate ,one-hand operation

l  Convenient automatic calibration function

l  Automatic correction function to prevent misuse calibration

l  Dynamically adapt to environmental features

l  V shaped groove suitable for measurements on cylindrical parts

l  Special probe structure has better stability

l  Beep when measurement or calibration is completed

l  180 degree flip for easy read data with top surface

 

Vision

Feature

PLN-CT2013FN  updated

Automatic temperature calibration version

According to the function it can be divided into the following version:

 

2 Product Appearance

The top is the LCD, the middle are three buttons, "+" "Menu" "-" ,on the bottom is the sensor.

 

 Elcometer with eddy current testing function for auto car paint coating

3 Technical Parameters

Measurement range: 0~1700μm, 0~67.8 mils

Accuracy: ± (2μm +3%H), H-standard coating thickness

Storage temperature: 10℃~60℃

Temperature: 0℃~40℃

Probe: built-in probe

Power supply: 2 x 1.5V(AAA  alkaline)

Body size: 96*50*25mm

Weight: 41g

4 Switching The Instrument ON/OFF

When the device is powered up, it needs to be detected itself automatically, so the open method is: using hand to press down the test probe and quickly leave,then the device shows “222” and a buzzer sound,when the device shows “---” complete automatic detection.

Note:

The probe do not close to the metal object when starting.

The buzzer will continue to alarm if the probe keep down after the device start.

The device will be shut down if does not operate within 30s.

5 Handling Instruction

5.1 Switch the display unit

In standby mode, press "+" key to switch between units of um and mil. After switching units, all of the interface will display in the unit except multi-point calibration state.

5.2 Switching display mode

After the standby mode or the measurement, the short press "-" key can be switched between the display and the back display.

5.3 Measurement methods

Place The instrument sensor contacts to the material for tested and pressed, wait 1 to 2 seconds after buzzer short beep sound, the measured data will be displayed on the LCD screen.

If the substrate material is different, the calibration should be carried out first and then measured.

Calibration method reference "standard piece calibration" section.

5.4 Historical Data

In standby mode Press "MENU" button once, you can enter to view the status of the historical data, instrument store up to 20 groups of historical data.

5.4.1 View historical data

After pressing the MENU screen displays "NO 0.", By a short press "+", "-", you can turn on the next turn data, save up to 20 data. "NO. X" indicates the most recent X time measurement data, the X greater  the data older.

5.4.2 Delete the historical data

Delete current data: In View mode, press "+", "-", select the data you want to delete, long press the "+" button.

Delete all: In View mode, long press the "-" button, can delete all the data. After you remove all 20 sets of historical data show non-ferromagnetic 0.0um.

5.4.3 View statistics

Enter the measuring status, continuous short press "MENU" key, can view the historical data in turn of maximum ,minimum value, average value ,then exit of the statistical value status(After boot, if the measurement of data, it is the last time of the measurement, otherwise it is no measurement value of white screen). If you want to directly measure , only need to put the instruments on the surface which you want to measuring ,it will automatically enter measurement status.

 

Note: the average value, the minimum value of the data is not measured in 0 of the data statistics.

5.5 Switch back-light

In view statistics :Enter the maximum mode (see 4.3.3) (bottom of the screen display MAX), press "+", you can open / close the back-light.

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating

Elcometer with eddy current testing function for auto car paint coating 

Cue Information

9 Cue Information

NO

Symbol

Meaning

Operate

Remarks

1

- - -

Standby state

Measurement /view

 

2

FFF

The measured value is greater than 1700 um or base material is not FE or NFE

 

 

3

AVG

Mean value

 

 

4

MAX

Maximum value

 

 

5

MIN

Minimum value

 

 

6

FE

Ferrum

 

 

7

NFE

Not Ferrum

 

 

8

um

Micron (Metric length unit)

Short press K1 can switch

 

9

Mil

Military (British length unit)

Short press K1 can switch

 

10

CAL

Calibration state

Caliberate

 

11

 

Low battery voltage

Change batery

 

12

E01

Misplaced calibration shim

Play the sult shim

 

13

222

On starting

Get away the probe from meatril object

 

14

NO

Numero symbol

Short press the “+”/ “-”

 

10  Key Description

NO

Key

Short press

in Key description

Long press

in Key description

Short press

in Calibrate

Long press

in Caliberate

1

+(Left)

Switch Unit

multi – point

calibration

Increase(Next)

Increase(Next)

2

MENU(Midle)

Check History Record

standard calibration

Enter(Exit)

Exit

3

-(Right)

Switch Show Direction

Initialization

Decrease(Last)

Decrease(Last)

Note:The standard calibration is also called single point calibration, some versions do not have this feature.

11 Common Problem

NO

Problem

Solution

1

Larger measurement

Deviation

If the deviation caused by the calibration error is large, or abnormal phenomenon shows FFF, please return to the factory after the re calibration

2

Battery alarm

When the screen appears battery logo alarm, please replace the battery, otherwise affect the measurement accuracy.The user does not need to use the device for a long time, it is recommended to remove the battery.

3

Users have their own base material

If the user has its own base material, it is recommended to calibrate their own material.

4

Backlight power

consumption problem

Has a relatively power consumption. If you want to save electricity, can turn off the backlight.

5

Boot alarm

The buzzer conuntinue alarm is due to the probe get away from the material object after start.

 

Packaging & Shipping


5 pcs gauges you received are with sample package. Now there are 2 types of regular package:

(1) 1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.

Elcometer with eddy current testing function for auto car paint coating

 

 

 (2) 5 complete sets of gauge package: 5 pcs gauge, 5 sets calibration, 5 instructions, 5 black glasses boxes, 1 white carton box whose outside is with the color cover.

 Elcometer with eddy current testing function for auto car paint coating

 

  

Company Information

Elcometer with eddy current testing function for auto car paint coatingElcometer with eddy current testing function for auto car paint coatingElcometer with eddy current testing function for auto car paint coating 

Our Services

Payment

1. We can accept T/T and western union and Money Order,paypal is just for sample fee.The best way is direcet online payment,you can choose yourself.If you want other payment terms please let us know before when you order.
2. Make sure that you have completed all the detailed information like contact person,address,post code and telphone number when filling in your buyer's information.

 

Shipping

Note:DHL/UPS/Fedex Express usually takes about 3-7 working days to the destination,and it's about 5-8 working days by EMS or TMT(except Russia,which will be delay for 15-30 days).HK Post and CN Post or SG Post takes 7-30 days to ship to worldwide.
1. We will send the goods within 3 business days after the full payment has been confirmed.If the payment is not available,your order will be closed automatically.
2. The buyers are responsible for any insurance,problems and damage which caused by shipping service such accidents,delays or other issues.Besides the buyer should to be responsible for any tax and/or duty charged by their country. (If you want to declare the goods as other item name,or specify an value for custom,please inform us when making the order.we could according to your detail desire  for your easy customs clearance and less charge.)

Feedback
1 Buyers early confirmation will be highly appreciated after receiving the items.
2 Since your feedback is very important to our business's development,we sincerely invite you to leave positive feedback for us if you are satisfied with our product and service.It'll just take you 1 minute,but this 1 minute has the extemely vital significance to us.

 

What we can do

1 All of our products have proceeded again test before shipment and we guarantee to use our products safety.
2 Support imprint your logo on products and let your logo shine anywhere.
3 OEM orders are warmly welcome!

 

Warranty and Return
1. All products and accessories have been tested by 3 times before ship out. And  all products have  1 year warranty. If there is no man-made problem, you can return back the goods for replace a new one , but your side need share the return back delivery cost, and we will share the shipping cost to your side agian . 

2. We own the best after-sale service.If any problems happen,our team will do our best to solve for customers.

3. All return items must be in its original conditions,including box and accessories.Men made defects are not guaranteed,such as broken,scratched and so on.
4 For any items,please send by DHL,Fedex or your local express or post when send back .

FAQ

1) How the coating thickness gauge shut down?
A: Our coating thickness gauge adopt with automatic shutdown, when you stop using it, it will be shutdown automatic after 30 seconds.

2) What angle should be kept with Coating thickness with the analyte ?
A: The probe must be kept perpendicular to the surface with the measured material, otherwise it will lead to considerable error.

3) How to maintain accuracy of measurement when we need repeatedly measurements ?
A: When we need repeatedly measure, the thickness gauge should be keep the distance more than 3cm away from the analyte and at least keep 2 seconds or more interval .(Attention :Do not drag along the surface to the side of the probe to avoid probe magnetization.it will be impact of next measurement result)

4) When should we to calibrate the Coating thickness ?
A: Our thickness gauge has been calibrated , in most time, we just need to check whether the uncoated substrate is normalized to zero .Usually when the measurement accuracy beyond the precision values ,it need to be calibrated (refer to the instructions precision value range) . Calibration method according to operating instructions.

5) When the Coating thickness display with"" ,What does it mean?

A: It indicates that the battery voltage is low, please replace the battery in the automatic shutdown, otherwise it will affect the measurement accuracy.

6) How to choose the zero substrate?
A: The thickness of zero substrate should be used as the test material to avoid the permeability of different materials and measurement errors.

7) How to choose the zero substrate surface?
A: Use the gauge should be in the same part of the material being tested after calibrating to zero, and then measuring the same part. If the measuring pipe, bar and other curve surface materials, but the user indeed calibrating to zero with substrate of flats surface , this will affect the accuracy of the measurement. And choose the calibrating zero surface should be more smooth.

8) Coating thickness gauge has been calibrated, why also the measurement also not accurately?

A: The coating thickness calibration could not choose the substrate random ,firstly calibrating to zero based on the same test material of substrate which without coating , then put the calibration sheet in the top to calibrate, so that could get reliable measurement data. Remember: Be sure to use the same shape, the same material, the same roughness zeroing calibration substrate.

9) Why the different coating thickness measured data is not the same?
A: Due to different coating thickness gauge calibrated with different substrate before use . For consistency, we should make them in the same uncoated substrate to do the zero calibration, and then put the calibration sheet in the top to calibrate, so different coating thickness measurement data will be keep consistent.

10) When should we to replace to Standard film ?
A: The coating thickness calibration depends on the calibration sheet, so it is very important that keep the calibration sheet in good condition. If the calibration sheet has been used for many years and not in a good condition, please replace it . Otherwise, the measurement data will be inaccurate.