Output Power 1 - 50W
Output Type Single
Input Voltage Other, 100-240V
Output Voltage 12V
Output Frequency 50-60Hz
Output Current 4A
Product Description

New 12V 4A 48W Wall mounted AC/DC Adapter/Power Supply

*  48Watt Wall Mount & Desk top Power Adapter

*  Universal Input 90 to 264VAC

*  RoHS Compliant

*  Meet /ErP / Energy Star / MPES Level : V

*  Meet EN55013 EN55022 FCC CLASS B

 

Product Specification

Sym  Parameter  Test Conditions  Min  Typ  Max  Unit 
  Operate Voltage Range   100    240  VAC 
fin Input Frequency   47    63  Hz 
Po Output Power Range Vin=90 to 264VAC   60
Vo Output Voltage Range   4   48
Io Output Current Range     8
Iil Input Current(Low Line) Io=Full Load,Vin=115VAC     0.8
Iih Input Current(High Line) Io=Full Load,Vin=230VAC     1
Irl Low Line Inrush Current Io=Full Load,25℃, Cool start,Vin=115VAC     60
Irh High Line Inrush Current Io=Full Load,25℃, Cool start,Vin=230VAC     120
Eff Efficiency Io=Full Load ,Vin=230VAC 87 89  
REG-i Line Regulation Io=Full Load  
REG-o Load Regulation Vin=230VAC  
OCP Over Current Protection Nil But,Output protected to short circuit conditions   %
Ttr Time of Transient Response Io=Full Load to Half Load,Vin=100VAC 2    
Thold Hold-Up Time Io=Full Load,Vin=100VAC 10  35 mS 
Ts Start Up Time Io=Full Load,Vin=100VAC 10  35 mS 
Vp-p Ripple&Noise (Peak to Peak) Full Load,Vin=90VAC  
Ilk Safety Ground Leakage Current Io=Full Load,Vin=240VAC     0.25  mA 
Pno No-Load Power Consumption No load, Vin=240VAC   0.2  0.3
TC Temperature Coefficient All output        

 

Enviromental

Sym  Parameter  Test Conditions  Min  Typ  Max  Unit 
Toper  Operating Temperature    25  40   ℃  
Tstg  Storage Temperature    -20    50   ℃  
Ho  Operating Humidity    15    90 
Hr  Storage Humidity    10    95 
MTBF  Operating Temperature at 25℃, Calculated per MIL-HDBK-217F   50000   Hrs 

 

Output Voltage And Current Rating Chart (Single Output):

Model Number.               Output Voltage           Max.Output Current           Total Regulation         Max.Output Watts
JKXXXYYY-S09                      4-9VDC                             0.01-8A                                 5%                               48W
JKXXXYYY-S09                     9.1-15VDC                       0.01-6.5A                               5%                               48W
JKXXXYYY-S09                    15.1-24VDC                      0.01-2.5A                              5%                                48W
JKXXXYYY-S09                    24.1-48VDC                      0.01-1.25A                            5%                                48W

The image of  New 12V 4A 48W Wall mounted AC/DC Adapter/Power Supply

New 12V 4A 48W Wall mounted AC/DC Adapter/Power SupplyNew 12V 4A 48W Wall mounted AC/DC Adapter/Power Supply  

New 12V 4A 48W Wall mounted AC/DC Adapter/Power SupplyNew 12V 4A 48W Wall mounted AC/DC Adapter/Power SupplyNew 12V 4A 48W Wall mounted AC/DC Adapter/Power SupplyNew 12V 4A 48W Wall mounted AC/DC Adapter/Power Supply

FAQ

 New 12V 4A 48W Wall mounted AC/DC Adapter/Power Supply

Send Inquiry to This Supplier

* Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2009
Factory Size
1,000-3,000 square meters
Total Employees
101 - 200 People