Home > Products > Communication line tester > Digital Cable Fault Locator for line in telecom industry
Digital Cable Fault Locator for line in telecom industry
- 100 Set / Sets per Month
- xi'an shaanxi
- T/T L/C D/P D/A
- ZTE 5928E, RS-5928E, RS-59EC-PWR-AC10, RS-59EC-PWR-DC10, 24 GE RJ45 + 1 expansion card ZTE ZXR10 5928E 5952E 5916E RS-5916E RS-
- ZTE 2952E, RS-2952E-AC, RS-2952E-DC, 48 FE RJ45 4 GE SFP ZTE ZXR10 2952E 2928E 2918E 2910E
- ZTE 3950-28TM, RS-3950-28TM-AC, 24 FE RJ45 + 2 GE SFP + 1 expansion card slot ZTE ZXR10 3950
- ZTE 2950-18TC, RS-2950-18TC-AC, 16 FE RJ45 + 2 GE Combo ZTE ZXR10 2950
- ZTE S2XF48A, 48-port 10GE SFP+ optical interface ZTE ZXR10 8902E 8905E 8908E 8912E RS-8902E RS-8905E RS-8908E RS-8912E
- ZTE 5250-28PM-H, RS-5250-28PM-H, 20 GE RJ45 (POE/POE+) + 4 GE Combo ports + 1 expansion card ZTE ZXR10 5250
Product Details
Place of Origin: | Shaanxi, China | Brand Name: | Aitelong | Model Number: | SAT-8C |
Product Description
Specifications
digital cable fault locator1. TDR cable fault locator
2. cable test finds the faults
3. testing methods of Pulse reflection
SAT-8C Digital Cable Fault Locator adopts international advanced electronic measurement technology, which is a compositive instrument that integrates with ATDR, resistance meter, megohmmeter and automatic bridge. It is applicable for localization of breakage, cross, poor electric insulation and other faults of various telephone cables, RF cables and coaxial cables.
- English menu, touch colorized screen, easy operation
- Contrast function for 2 waveforms
- USB interface
- Megohmmeter and ohmmeter’s functions
- Built-in 2Ah lithium-ion rechargeable battery
Widely Used
- Testing methods of Pulse reflection and intelligent bridge with both full-automatic and manual testing functions.
- Testing for insulation resistance and loop resistance. The range of insulation resistance :0~~50MΩ
- Automatical detection the line status: breakage, cross, poor electric insulation and the high voltage of the line
- DAGC(Digital Automaitc Gain Control) and DWAR (Digital Waveform Automatic Recognize) can automatically recognize the waveforms unable to be judged by manual testing.
- Field calibration function (unknown cable parameter: speed or diameter; correction for distance of cable, automatic memory the correction result); the correction cable function
- Adapt for 0.32mm,0.4mm,0.5mm,0.6mm’s telephone cables
- Memory stores 10 testing waveforms. Measurement result can upload to PC, and take it for consulting, analyzing and printing
Technical parameters
Pulse reflection testing method
| Full-automatic measurement range | 0~8 km |
Testing accuracy
| 1 m for measurement range: ≤ 2 km. Accuracy: ±2%. | |
8 m for measurement range: ≥ 2 km. Accuracy ±2% | ||
Testing dead zone | 0 km | |
Pulse width | 60ns-10μs automatic adjustment | |
Wave velocity | 0 ~ 300 m /μs | |
Vertical gain | Range: 80 dB. Accuracy: 1 dB. | |
Impedance | 135 Ω (accuracy 1% ) | |
Bridge testing method | Testing range for Poor insulation resistance | 0~50MΩ |
Testing length | Full length 9999m | |
Sectional 9999m×3 sections | ||
Testing error rate | 1% × Full length of line | |
DMM Technical index |
Insulation resistance | 0 ~ 50MΩ |
Minimum resolution:10 kΩ. Accuracy: ±3% | ||
Loop resistance
| 0 ~ 9 kΩ. | |
Minimum resolution: 0.1 kΩ, Accuracy: ±3% | ||
Voltage | AC/DC voltage 0 ~ 250V. | |
Minimum resolution 0.1V, Accuracy: ±5% | ||
Capacitance | 0-1.3uF. | |
Minimum resolution: 1nF, Accuracy: ±5% | ||
Power supply | AC Power | External AC power supply / Charger |
Working time | 6 hours at most | |
Charging time | 4 hours | |
Dimensions(L x W x H) | 220 m m x 162 mm x 48mm
| |
Weight | 950g | |
Working temperature | -10~ 50 °C | |
Storage temperature | -30~ 70 °C | |
Humidity
| 5%-90%(non-condensing) |
Contact Us
- Shaanxi Aitelong Technology Co., Ltd.
- Contact nameShunli Xie
- Phone86-29-65660081
- Address2, Building 11, Technology Enterprise Accelerator, No. 2, West Of Qinling Avenue, Caotang Science And Technology Industry Base, High-Tech Zone
Battery testing and maintenance | Communication line tester | Data transmission testing | New Products |
Resistance testing |
- FortiGate FortiWiFi 80F Series FG-80F/FG-81F
- 2x2 Magnet Fiber Optical Switch 1550nm
- 1550nm 1x4 Magnet Fiber Optical Switch SM
- 1520-1580nm 1x2 Magnet Fiber Optical Switch
- Magneto optical switch 1XN
- Magneto optical switch 1X1
- Magneto optical switch 1X1
- Magneto optical switch 1X4
- Magneto optical switch 1X2
- MEMS optical attenuator module
- PM MEMS VOA module
- Multi-channel MEMS VOA module
Popular Searches
- Optical Amplifier
- joint closure
- fiber optic
- ftth
- telecommunication
- Camera Dome Enclosure
- video transceiver
- distribution box
- Fiber Optic Equipment
- fusion splicer
- optical fiber splicing machine
- fiber optic fusion splicer
- fiber optic adapter
- optical fiber fusion splicer
- machine fiber optic fusion
- fiber optic splicing kit
Recommended Products
- Wireless telephone DECT cordless telephone
- FortiGate FortiWiFi 80F Series FG-80F/FG-81F
- 2x2 Magnet Fiber Optical Switch 1550nm
- 1550nm 1x4 Magnet Fiber Optical Switch SM
- 1520-1580nm 1x2 Magnet Fiber Optical Switch
- Magneto optical switch 1XN
- Magneto optical switch 1X1
- Magneto optical switch 1X1
- Magneto optical switch 1X4
- Magneto optical switch 1X2
- Cisco Fiber Switches N9K-C93180YC-FX
- MEMS optical attenuator module
Find Similar Products By Category
- Telecommunications > Communication Equipment > Fiber Optic Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shunli Xie
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-