Home > Products > x-ray film positioning system > LK1900 Autoclavable Xray Film Positioning System
LK1900 Autoclavable Xray Film Positioning System
- 200 Carton / Cartons per Month
- Shenzhen
- T/T Credit Card
- Digital x-ray films printer, Dry Films printer, Thermal films printer
- Digital x-ray films,Dry Films, Thermal films for Digital x-ray
- Fuji films, X-ray films, Green sensitive films, blue sensitive films
- Bone and Lung CT Scanner, 16 Slice CT, 32 Slice CT, 64 Slice CT scan
- Permanent MRI Machine, Superconductivity MRI Machine
- High quality Mobile Xray machine
Product Details
Properties: | Other, Medical X-ray Equipments & Accessories | Brand Name: | LK | Model Number: | LK1900 |
Place of Origin: | Guangdong, China |
Product Description
LK1900 Dental X-ray locator (Dental Product, Dental Device, Film Positioning System Complete)
DESCRIPTION:
Helping you create perfect radiographs
LK1900 film positioning system has made your guide to perfect x-rays much easier. LK3000 is the most comprehensive and durable system available today.
1) Fully color-coded and user friendly, and lightweight for patient comfort and easy assembly.
2) Aligns film to prevent cone cutting.
3) Rounded bite blocks with no sharp edges improves comfort.
4) Open bite block design offers patients a soft bite.
5) New bitewing shape with same-arch biting for a more closed bite.
6) Can be used for anterior, posterior, bitewing and endodontic procedures.
7) Can be used for all intra-oral dental x-ray lm size #0, #1, #2 and #3.
8) Endodontic instrument safely straddles the subject tooth, providing precise film alignment without obstruction.
9) Shorter arms tall intra oral x-ray units.
10) As always, all components are fully autoclavable, designed to endure repeated sterilization without discoloration or brittleness.
11) Available in complete kit or as individual components.
CLEANING & STERILIZATION:
1. Disassemble instrument(s).
2. Remove debris from components with hot water or soap.
3. Place components in sterilization pouches, and place in the middle tray. Plastic parts must be in a separate pouch from metal arms, to avoid melting or warping.
4. Cycle per autoclave manufacturers instructions.
Do not exceed 270 degree F (132 degree Celcius). DO NOT CHEMICLAVE OR DRY- HEAT STERILIZE. DO NOT COLD STERILIZE
. 5. Note: Plastic parts have a limited life and should be replaced periodically. Any method of sterilization will shorten the life of plastic parts.
POSITIONING INSTRUCTIONS:
1. Assemble instrument. Be sure the bite-block is centered in aiming ring.
2. Place appropriate size film in instrument with imprinted side of film away form x-ray tube head.
- White toward light, place plain or white side of film toward x-ray tube head.
- Do not bend back the bite block when inserting the film.
3. Position instrument in patients mouth as posterior as possible, away from the teeth and in the mid-palatinal or mid-tongual area. Center film on the teeth to be radiographed.
-Lean and tip - lean the chair back just a little and/or tip the patients chin up to facilitate placement of the FPS instrument into the center of the patients mouth. For exposure, the occlusal surface should be parallel to the ground.
- For bitewing exposures, the patient should be biting on the same arch as the teeth being radiographed. When assembled correctly, the bitewing instrument should hold the lm with the plain side facing the bite-blocks bite surface and the x-ray tubehead.
- For endo, place the instrument over the tooth, les and clamps, resting on the adjacent teeth. If using a rubber dam, release the top or bottom of the dam from the frame. he dam and frame do not need to be removed.
4. Instruct patient to close slowly and bite. A cotton roll can be placed between the bite block and the opposite teeth for added comfort and stability.
- Gentle; breath - ask the patient to gent bite down and then take several breaths; it gives them something to concentrate on other than the radiograph procedure.
5. Position tubehead parallel to indicator arm and centered on aiming ring.
6. Make exposure.
Includes:
5pcs aiming rings
(2 pcs) Posterior - yellow
(1 pcs) Anterior - blue
(1 pcs) Bitewing - red
(1 pcs) Endodontic - green
5pcs indicator arms
(2 pcs) Posterior - yellow
(1 pcs) Anterior - blue
(1 pcs) Bitewing - red
(1 pcs) Endodontic - chrome (metal)
19pcs bite blocks
(8 pcs) Posterior bite block - yellow
(4 pcs) Anterior bite block - blue
(5 pcs) Bitewing bite block - red
2-#2H, 1-#2V, 1-#0/1H, 1-#1V
(2 pcs) Endodontic bite block - green
Contact Us
- Lakong Medical Devices Co., Ltd.
- Contact nameNancy Lai
- Phone86-769-81807881-233
- AddressShichong Industrial Park, Shipai Town Dongguan,Guangdong
- 100ma 200ma 300ma Analog Xray machine with table
- 50ma 70ma 100ma Analog Xray machine,mobile Xray machine
- Analog Mammography Xray machine,Digital Mammography Xray machine
- Medical radiation protection series products Lead suit and lead cap
- Lead suit and lead cap medical radiation protection series products
- Portable Dental X-ray Machine
- The handheld JLDG JD-3001 nuclear radiation detector is highly accurate and can detect XYB rays
- EMF Meter BR-6 Geiger Counter Series Professional Nuclear Radiation Detector Dosimeter Monitor Radiation Tester Easier Operation
- FS2011+ Nuclear Radiation Detector Dosimeter Measuring Instrument Alarm Isotope Detection &X-rays Y-rays B-rays
- NT6102 Nuclear Radiation Detector Personal Radiation dose alarm
- waterproof geiger counter portable industrial nuclear radiation detector dosimeter
- radiation dosimeter industrial radiation monitor watch waterproof geiger counter alpha beta gamma x-ray detector
- Medical X-ray diagnostic system (double column)/medical X-ray diagnostic system
- Portable high frequency X-ray machine/medical X-ray diagnostic system
- Wide Band Linear array Multi-angle Transducer GE 9L-RS
- New GE 6S-RS Phased Array ultrasound transducer probe
- GE C1-5-RS wideband convex transducer
- GE 8C-RS Micro convex ultrasound transducer
- 11mm transducer GE E8C-RS Portable Voluson, Logiq, and Vivid series
- GE L6-12-RS linear ultrasound transducer probe
- New Original GE 12L-RS linear ultrasound transducer
- GE 4C-RS Original Curved Array Transducer probe
- Infusion Pump i7
- AG-MPD56A 5.6kw Mobile Portable DR X-Ray Machine Digital Radiography Equipment
Popular Searches
Recommended Products
- Low Speed Dental Handpiece
- High Quality Dental Medical Autoclave Door Gasket Door Seal O-ring For BMS & NewMed
- Dental Medical Door seal chamber seal o-ring For Taus
- Dental High Speed Handpiece
- Light-Curing Resin Placement Rack
- Dental Medical Autoclave Door Gasket Silicone For W&H,Lisa
- Imported 6 Hole Optical Fiber Handpiece Tube
- 6 Hole Optical Fiber Handpiece Tube For Dental Chair
- 4 Hole Handpiece Tube High Quality Silicone Dental Chair Accessories
- Handpeice Tube Imported 4 Hole High Quality
- delivery room stroller
- Disposable Sterile oral instrument kit,disposable dental kit
Find Similar Products By Category
- Health & Medical > Medical Devices > Radiology Equipments & Accessories
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Nancy Lai
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-