Home > Products > Active Harmnoic Filter > active power filter for electricity saving
active power filter for electricity saving
- 200 Set / Sets per Month
- Qingdao
- T/T
Product Details
Place of Origin: | Shandong, China | Brand Name: | Hoteam | Model Number: | HTQF series |
Product Description
Specifications
1.ripple wave cancellation technology2.harmonics Fractional compensation
3.can work under high temperature
4.R&D department
Introduction of Functions
Harmonic Filter:HTQF is composed of command current computing circuit and compensation current generating circuit. Command current computing circuit conducts real-time monitoring of current in circuit; switch the analogue current signals into digital signals, and send the signals into DSP for handling; separate harmonics and fundamental wave, send drive pulse in form of PWM signals to compensation current generating circuit; drive IGBT power module, produce compensation current input network which has the same amplitude as harmonic amplitude and inverse polarity; compensate or balance out harmonic current, eliminate power harmonics actively, and thus realize the dynamic quick and complement treatment of power harmonics.
Dynamic reactive power compensation: While filtering harmonics, according to detected need for reactive power compensation, HTQF command current computing circuit can control internal capacitive and inductive fundamental current of compensation current generating circuit, conduct real-time compensation, set the target value of reactive power compensation through operation board. There are 4 working modes for choice, namely, “filter priority”, “reactive power priority”, “harmonic filter only”, “and reactive power compensation only”. The working mode should be selected according to specific conditions of power distribution system.
Correct unbalanced 3 phases:HTQF can compensate the unbalanced 3 phases respectively. It can conduct phase adjustment of active power through DC Energy Storage Systems shared by 3 phases, thus to correct unbalanced load of 3 phases. The operation of this function can also be set by operation board.
HTQF technical parameters
model | HTQF/3L-0.4/xxA 3P3L | HTQF/4L-0.4/xxA 3P4L |
feature | ||
| Apply to 3P3L system | Apply to 3P4L system, can realize netral line filter |
Compensation current of each cabinet | 50A | 50A |
75A | 75A | |
100A | 100A | |
150A | 150A | |
200A | 200A | |
250A | 250A | |
300A | 300A | |
400A | 400A | |
500A | 500A | |
600A |
| |
input | ||
voltage | 400/600V -15/+10% | 400/600V -15+10% |
frequency | 50/60HZ ±5% | 50/60HZ ±5% |
Performance index | ||
Filter capacity | Can be more than 97% | Can be more than 97% |
Filter range | 2~50th harmonic | 2~50th harmonic |
Response time | Transient response<0.1ms, complete response<20ms | Transient response<0.1ms, complete response<20ms |
Neutral line compensate ability | ---- | 3 times in line RMS current |
Reactive power compensation | Setting range of power factor is from inductive0.6 to capacitive 0.6 | Setting range of power factor is from inductive0.6 to capacitive 0.6 |
Balance compensation | Programmable balance of power
| Programmable balance power of phase and phase or phase and neutral line |
Overload protection | Automatic current limiting when 100% rating output | Automatic current limiting when 100% rating output |
Power loss | ≤3% rated compensation capacity | ≤3% rated compensation capacity |
CT requirements | 3set, 0.2magnitude or more,secondary 5A | 3set, 0.2magnitude or more,secondary 5A |
Current detection means | Source current detection or load current detection | Source current detection or load current detection |
Display and interface | ||
language | English/Chinese | English/Chinese |
Operating button | Start/stop,reset,menu,confirm,fluctuation function keys and so on | Start/stop,reset,menu,confirm,fluctuation function keys and so on |
Indicator light | Green: normal operation | Green: normal operation |
Orange: overcurrent/overload operation | Orange: overcurrent/overload operation | |
Red: machine halt or alarm | Red: machine halt or alarm | |
Communication interface | RS-485 | RS-485 |
Communication protocol | MODBUS(RTU) | MODBUS(RTU) |
digitI/O | 4 digital input, 2 digital alarm | 4 digital input, 2 digital alarm |
configuration | ||
Unit operation | allow | allow |
Parallel operation | 10 sets at most | 10 sets at most |
IP | IP3X,(higher IP pls contact manufactuer) | IP3X,(higher IP pls contact manufactuer) |
Color | RAL7035(light gray), can be customized according to use requirements | RAL7035(light gray), can be customized according to use requirements |
Environment condition | ||
temperature | -10~40°C | -10~40°C |
Storage temperature | -25~55°C | -25~55°C |
Relative humidity | Max 95%RH(no condensation) | Max 95%RH(no condensation) |
altitude | 1000m | 1000m |
Contact Us
- Shandong Hoteam Technology Group Co., Ltd.
- Contact nametommy liu
- Phone86-0531-82670172
- AddressBldg. 6, No. 2600, Yingxiu Rd., High-Tech Development Zone
Active Harmnoic Filter | Modular type Active Power Filter | New Products | Reactive Power Compensation Panel |
- monopole steel tower
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
- overhead Line fault indicator for installation methods and tools
- Flag type Overhead type Short circuit &Ground Fault Indicator
- High Voltage Cable Fault Alarm
- overhead line fault sensor
- SNV-QS High Voltage Live Display Locking Device
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- EKL4 Cable Short Circuit and Grounding Fault Indicator
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- medium voltage overhead line fault current sensor and indicator
- Overhead type Short circuit & earth Fault Indicator manufacturer
- earth fault indicator distribution system
Popular Searches
Recommended Products
- HONEYWELL 05701-A-0325 communication module
- HONEYWELL 05074-A-012 0574-A-0131 Servo motor module
- HONEYWELL 0574-A-0121 0574-A-0131 Relay interface card
- HONEYWELL 0574-A-012 0574-A-0131 Servo motor module
- VIBRO-METER 200-510-070-113 200-510-111-034 VM600 MPC4 Vibration monitoring instruments
- GE IC693CPU374-GU Input output module
- ABB DSSR122 48990001-NK DC input power unit
- MTL 8715-CA-BI Logic input module
- MTL 8502-BI-DP Bus interface device
- HIMA X-SB01 985210207 System bus module
- HIMA X-FAN1003 993201013 Discrete I/O controller
- HIMA X-DO1201 985210204 Control signal transmission module
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
tommy liu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-