Home > Products > Others > High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree
High precision cooling and heating unit apply to Glass-Lined reactor temperature range from -50 to 250 degree
- 200 Set / Sets per Month
- shanghai
- Sterile vacuum vegetable cooling machine
- Green Precooling Vegetable Sterile cooling machine
- Vegetables Fruits Fresh vacuum precooling machine
- Precision air conditioner for computer room & data center
- Rooftop packaged air conditioner unit for commercial and industry use
- Hitachi heat pump scroll compressor DD98NHDG-D1K2 DC frequency conversion R410A
Product Details
Type: | Other, Temperature control system | Place of Origin: | Jiangsu, China | Brand Name: | LNEYA |
Model Number: | SUNDI-535WN | Certification: | CE, Other, CE, ISO | After-sales Service Provided: | Overseas third-party support available |
Product Description
Dynamic Temperature Control systems
SUNDI -50℃ ~ 250℃ Parameter
Typical Applications
Reactor Systems Autoclaves
Pilot Systems
Mini Plant Systems
Scale up for Operational Development
Double wall reactors
Advanced-Flow Reactors
Distillation Systems
Material Testing
Combinational Chemistry
Semiconductor Industry
Vacuum Chambers
Advantages & Functions
Working temperatures from -100℃ to +350℃
Previously unachievable performa
Intelligent temperature control
Maximum process stability and reproducibility
Adop plate heat exchager,Pipeline heating,
the fastest heating and cooling rates.
High cooling power
Large temperature range without fluid change
Closed system,extend thermal fluid lifetime
Incredibly compact
7-inch,10-inch color TFT touch screen display
Comprehensive warning and safety functions
Rapid cooling down from high temperature
Use magnetic drive pump,solve the circulation pump leakage
Structure design
A fully closed piping design, high efficiency plate heat exchanger used to reduce the
demand for the thermal fluid utilization while providing the system to achieve the rapid
ups and downs in temperature The whole system is a closed liquid circulation system
with the expansion of container, expansion of the container and the liquid circulation is
adiabatic, and do not participate in liquid circulation, only mechanical connection,
no matter the temperature is a high temperature or low temperature, the tank
temperature is limited to 60℃. Therefore, during the process the risk of imbibing
and volatilization of the heat conducting medium is reduced. There following
advantages
for the user.
Only the heat conduction medium in the expansion container touches the oxygen
in the air. (The container temperature is limited to 60℃).
No volatilization of the heat conducting medium at high temperature.
No need to change the heat conducting medium. Continuous control of the temperature
of the below range can be done without rising the pressure: -80℃~190℃, -70℃~220℃,
-88℃~170℃, -55℃~250℃, -30℃~300℃.
Display funcation
The Refrigeration system displays various information on the touch screen.
1. Displays all the kind of process control temperatures.
2. Shows the liquid level of the heat conducting medium in the expansion vessel.
3. Shows indication for refrigeration system working.
4. Shows indication for heater working.
5. Shows indication for circulation pump working.
6. Displays the temperature control (materials temperature control pattern, heat
conducting medium temperature control ).
7. The temperature upper limit, lower limit control can be set.
8. The temperature difference between jacket & reactor material can be set.
9. Shows the alarm to add the liquid when it is empty.
10. The refrigeration compressor can be set to operate manually or automatically.
11. Simple Menu to use.
Process Control Schematic diagram
Change the control settings of the method, the response as soon as possible in the
process of the system lags behind, be the smallest system overshoot. Controlled by
two PID (PID is a variable in each group) control loop structure, known as the two
sets of control loops: the main circuit and from the circuit, the main control loop from
the loop output as the settings.
System with feedforward with PV, the master PID loop operation results of the PV
output and feedforward signals as the composite of the settings from the control loop,
through such control of the temperature gradient to ensure the accuracy of temperature
control system.
High repetative of tempeature control effect
Each cycle curve slope is consistent and greatly improve the consistency of production thermostatically control environment.
Circulation Pump
High temperature resistant low temperature magnetic drive pump or a leak-free high
and low temperature shield-driven pump, reduce the risk of system leakage. At the
same time the system has the advantages of low noise and big traffic flow.
Connecting Pipe
LNEYA Dynamic Temperature Control systems in practice
In comparison to other thermal control systems, Dynamic Temperature Control systems
differ sometimes considerably in their thermodynamic characteristics. In practice Dynamic Temperature Control systems offer definite advantages in your work: noticeably shorther heating and cooling times, better stability and reproducibility through the entire process
chain, greater safety for expensive glass reactors and the contained substances, together
with simple and easy operation.
Heat Conduction Medium
It is important to choose the suitable heat conduction medium, to make sure that
system works stably.To choose the suitable medium according to the working
temperature of the system is essential.
The package kinds of LNEYA heat conduction medium are 10L, 25L, 30L, 200L.
when ordering the heat conduction medium, the heat conduction medium for constant
temp control system, channel, and external circulation equipments.
Technical Parameters:
Model | SUNDI-525W N
| SUNDI-535WN
| SUNDI-555W SUNDI-555 | SUNDI-575W SUNDI-575 | SUNDI-5A10W SUNDI-5A10 | SUNDI-5A15W
| |
Temperature range ℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | -50℃~250℃ | |
Control Mode | Feed forward PID + Our special dynamic control calculation, PLC controller | ||||||
Temp. control | Option: process temperature control or jacket oil temperature control | ||||||
Temp. difference | Set or control the temperature difference between jacket oil and raw material process | ||||||
Program Editor | 20 programs, each program can edit 45 steps. | ||||||
Communication protocol | MODBUS RTU Protocol, RS 485 Interface | ||||||
Temperature feedback | Heat-conducting medium: PT100 Raw material process: PT100 | ||||||
Temp. accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ | |
Heating power | 2500W | 3500W | 5500W | 7500W | 10000W | 15000W | |
Cooling capacity | 250℃ | 2000W | 3500W | 5500W | 7500W | 10000W | 15000W |
100℃ | 2000W | 3500W | 5000W | 7000W | 10000W | 15000W | |
20℃ | 2000W | 3500W | 5000W | 7000W | 10000W | 15000W | |
0℃ | 1800W | 3000W | 5000W | 7000W | 10000W | 15000W | |
-20℃ | 850W | 1500W | 2850W | 4200W | 6000W | 11000W | |
-40℃ | 250W | 450W | 900W | 1500W | 2000W | 3750W | |
Circulation pump | Max20L/min 2BAR | Max20L/min 2BAR | Max35L/min 2BAR | Max50L/min 2.5BAR | Max50L/min 2.5BAR | Max110L/min 2.5BAR | |
Compressor | Tecumseh | Copeland | Copeland | Copeland | Copeland | Copeland | |
Expansion valve | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | Danfoss | |
Oil separator | Emerson | Emerson | Emerson | Emerson | Emerson | Emerson | |
Evaporator | KAORI Plate heat exchanger | ||||||
Operation Panel | 7-inch color touch screen controller,temperature curve record,data export to excel format. | ||||||
Safety protection | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. | ||||||
Closed | The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supplement oil automatically at low temperature. | ||||||
Refrigerant | R-404A | R-404A | R404A | R404A | R404A | R404A | |
Connection size | DN-15 or M24*1.5 | DN15 or M30*1.5 | DN20 or M30*1.5 | DN20 or M30*1.5 | DN20 or M30*1.5 | DN-25 M38*1.5 | |
Water-cooled type W (cooling water at 20℃) | 600L/H 1.5bar~4bar | 800L/H 1.5bar~4bar | 1500L/H 1.5bar~4bar | 1800L/H 1.5bar~4bar | 2600L/H 1.5bar~4bar | 3200L/H 1.5bar~4bar | |
Dimension | water-cooled | 400*600*1050 | 400*600*1050 | 600*700*1150 | 600*700*1150 | 600*700*1150 | 700*700*1250 |
air-cooled |
|
| 550*680*1450 | 620*700*1450 | 700*700*1750 |
| |
Weight | water-cooled | 160kg | 185kg | 245kg | 285kg | 320kg | 360kg |
air-cooled |
|
| 280kg | 320kg | 360kg |
| |
Power | AC 220V 50HZ 4.5kW (max) | AC 380V 50HZ 6.A5kW (max) | AC 380V 50HZ 9kW (max) | AC 380V 50HZ 12.5kW (max) | AC 380V 50HZ 16.5kW (max) | AC 380V 50HZ 24kW (max) | |
Case material | SUS 304 | SUS 304 | SUS 304 | SUS 304 | SUS304 | SUS304 | |
Optional | Optional Ethernet interface, configure PC operating software | ||||||
Optional | Optional outside touch screen display controller (separated), the communication line distance is 10 meter. | ||||||
Optional power | 220V 60HZ three-phase, 440V~480V 60HZ three-phase |
Ancillary use and test area:
2015 Corning Reactor and its Ancillary Equipment Technology Exchange Meeting
Contact Us
- Wuxi Guanya Refrigeration Tech Co., Ltd.
- Contact nameLisa Li
- Phone0086-510-82321181
- AddressNo.10, Zhenfa No.1 Road, New district, Wuxi, Jiangsu, China Wuxi,Jiangsu
- Hitachi DC frequency conversion CA80NHDG-D1K2 heat pump compressor special for low noise cold storage
- VRR24M-B Air Conditioner Refrigerant Recovery Cylinder Recovery Unit For Refrigerant value
- RR250 Portable Refrigerant Recovery Machine
- RR500 Portable Auto AC Refrigerant Recovery Recycling Machine R32 Refrigerant Recovery Cylinder hvac recovery machine
- CM-R32 Refrigerant Recovery Machine Price Refrigerant Recovery Unit
- TRR24A Air Conditioner Refrigerant Recovery Cylinder Refrigerant Recovery Machine Price
- compressor condensing unit for showcase
- other refrigeration & heat exchange equipment
- Factory direct high reliability heat exchanger can be used with dryer and dehumidifier
- High reliability and energy saving aluminum microchannel heat exchanger evaporator more applications more energy saving
- Auto Production Line Equipment Air Conditioner Production Refrigerator Gas Charging Tool
- AC Factory Automatic Production Line Equipment Machine AC Gas Charging Kit
- Air Conditioner Factory Build Automatic Production Line Equipment Machine Fin Press Line Punching Machine
- Ac Factory Build Fully Automatic Production Line Production Equipment High Speed Fin Press Machine
- Air Conditioner Production Equipment R22 R410a R32 AC Gas Charging Machine
- Air Conditioner Production Heat Exchanger Workshop Line Aluminum 125T Fin Press Machine
- HT-350 Huabon Thermo truck refrigeration unit Chinese Supplier cheap price
- transport freezer kits for sale buy cheap truck refrigeration unit
- Pick up van refrigeration unit for refrigerated box to keep goods frozen
- Chinese Supplier Hubaon Thermo refrigeration units for small trucks containers
- Huabon Thermo HT-280 food refrigerated van container for sale
- Huabon Thermo food refrigerated van container for sale
- Hubaon Thermo direct engine driven small front mounted van refrigeration unit for sale
- HT-200 Hubaon Thermo hot product small front mounted van refrigeration unit for sale
Popular Searches
- ac units
- compressor condensing unit
- Cold Equipment
- electronic control unit
- temperature control unit
- electronic unit
- Portable Power Unit
- portable ac unit
- Diaphragm Compressor
- Electric Unit
- parallel compressor unit
- refrigeration compressor unit
- r600 refrigerant recovery pump
- container storage units
- portable storage unit
- r600a refrigerant recovery pump
Recommended Products
- Fortuna bandknife splitting machine AN400 leathe splitter 400mm
- Fortuna bandknife splitting machine NAF470 leathe splitter 470mm
- Atom SP588 travelling head presses oildynamic cutting machine
- YV100II MULTI CAMERA + LED
- YV100II folder side cylinder KG7-M9236-00X
- YV100II camera complete data line include light source board
- YSM20R support for change direction KKE-M9164-01 KLW-M9161-00 KLW-M916D-00
- YSM20 pulley KLF-M9150-00
- Atom clicking presses VS922 hydraulic die cutting machine 22 tons
- YSM KMK-M653B-00 Fiber+Amp
- YSM KLC-M9192-00X FIBER
- YS24X blade KKE-M9125-00
Find Similar Products By Category
- Machinery > Refrigeration & Heat Exchange Equipment > Other Refrigeration & Heat Exchange Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lisa Li
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-