Home > Products > TRANSFORMER > dry type transformer
dry type transformer
- 100 Unit / Units per Month
- mumbai
- T/T L/C D/P D/A
- Acrel ABAT-S battery-powered module device for Battery Monitoring System less than 13mA (1.2V&2V) or 7mA(6V&12V)quiescent
- Acrel ABAT-S battery analyzer monitoring system On-line monitoring of the voltage internal resistance of each backup battery
- Acrel ABAT-C Battery Monitoring Module Lead Battery Charge Discharge output 4-20mA
- Acrel ABAT Battery Monitoring System used for Base Station for 2V/6V/12V Lead Acid Batteries with RS485 communication
- Acrel ABAT-S battery analyzer monitoring system Interfaces with most UPS controller
- Acrel ABAT-S Lead-acid module device per battery to monitor internal resistance voltage and temperature
Product Details
Place of Origin: | Gujarat, India | Brand Name: | PEC | Model Number: | 1500 kva |
Product Description
Specifications
dry type transformer100 TO 7000 KVA
Indoor / outdoor unit substations
Industrial and petrochemical plants
Offshore
dry type transformer
MANUFACTURING STANDARDS
The transformers described in this catalogue are designed and tested in accordance to the European Union Harmonisation Documents HD 538 and HD 464 as well as IEC 726, IEC 76. standards. However, and by request, they can be manufactured according to other national or international standards.
RATINGS 100 - 160 - 200 - 250 - 315 - 400 - 500 - 630 - 800 - 1000 - 1250 - 1600 - 2000 - 2500 - 3000 - 3500 KVA .
HIGH VOLTAGE
This material is designed for voltages of ≤ 36 kV. Specific figures are not given for this parameter because of the wide variety of voltages used. Transformers can be supplied on demand to run at two different primary voltages.
LOW VOLTAGE
The no load low voltage is allocated at 420 V, though other voltages can be supplied on demand. When usage requires two voltage
transformers with two simultaneous voltages can be supplied. In this case the no-load voltages are set to 420 and 242 V.
SPECIAL PURPOSE EPOXY CAST RESIN TRANSFORMER
• Moisture proof
• No partial discharge
• High overload capability
• Superior Impulse voltage strength
• Short-circuit damage resistance.
• Thermal shock resistance
• Superior fire resistant design
• Maintenance free
• Environmentally safe
• Very low noise
• Very low operating cost.
Special Purpose Transformers
The special purpose transformers found their application in areas where the voltage requirement of the machines available differ significantly from the standard voltage. Our special purpose transformers are at the forefront in the industry. We strictly adhere to the international quality standards while manufacturing these transformers. We also entertain custom requirements up to 5000 kva.
TECHNICAL PARTICULARS DESCRIPTION | UNIT | PARTICULARS | ||||||||||
Continuous rating | KVA | 100 | 200 | 315 | 500 | 630 | 750 | 1000 | 1250 | 1600 | 2000 | 2500 |
Supply voltage | KV | 11 | 11 | 11 | 11 | 11 | 11 | 11 | 11 | 11 | 11 | 11 |
Normal voltage ratio at normal tap | KV | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 | 11 / 0.433 |
BSS vector Group | - | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 | D y n 11 |
Method of cooling | - | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN | ONAN |
Maximum temperature rise at normal loading | Deg. C. | |||||||||||
40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | ||
a) Oil | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | |
b) Winding | ||||||||||||
Impulse level | KVp | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 |
a) 1/50 full wave | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | 75 | |
b) 1/50 chopped wave | ||||||||||||
Max. flux density at normal voltage and frequency | Tesla | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
Max current density | A / mm | |||||||||||
2.95 | 2.95 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | ||
a) Primary winding | 2.85 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 | |
b) Secondary winding | ||||||||||||
Iron loss at normal voltage & tapping | W | 220 | 460 | 650 | 850 | 950 | 1200 | 1250 | 1650 | 2000 | 2300 | 3000 |
Copper loss at rated load & 75 deg. C. | KW | 1.8 | 3.1 | 4.2 | 6.1 | 7.2 | 8.2 | 11.5 | 13 | 19 | 23 | 25.5 |
Magnetizing current % of full load current | % | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 | 1.5 |
Total oil required | Ltrs | 201 | 276 | 385 | 490 | 610 | 675 | 800 | 900 | 1050 | 1250 | 1500 |
Weights | Kgs | 322 | 490 | 770 | 1100 | 1230 | 1340 | 1600 | 1750 | 1875 | 2000 | 2400 |
Core and Winding | 706 | 1054 | 1494 | 2248 | 2460 | 2700 | 3300 | 3600 | 3900 | 4500 | 5200 | |
Complete trf. with oil | ||||||||||||
Overall dimensions (appx) | mm | |||||||||||
a) Height | 1420 | 1535 | 1650 | 1975 | 1975 | 1975 | 2100 | 2200 | 2200 | 2300 | 2300 | |
b) Length | 1080 | 1235 | 1450 | 1630 | 1630 | 1630 | 1700 | 1700 | 1700 | 1800 | 2000 | |
c) Width | 1055 | 1065 | 1130 | 1560 | 1560 | 1560 | 1700 | 1900 | 2100 | 2500 | 3000 | |
Contact Us
- POWER ENGINEERS COMPANY
- Contact nameATUL KHOSLA
- Phone91-9714-777713
- Address967/2/2, GIDC, MAKARPURA,
- Power distribution
- Junction box
- Enclosure box
- Electrical distribution box
- Overhead Line High Voltage Line fault locator Device
- earth fault indicator distribution system
- big diameter welded steel tube
- wind tower pole
- substation steel structure
- monopole steel tower
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
- overhead Line fault indicator for installation methods and tools
- Flag type Overhead type Short circuit &Ground Fault Indicator
Popular Searches
Recommended Products
- Drone Battery 14.8V 2250mAh 25C 18650 li-ion lithium ion battery pack for aircraft UAV
- Drone Battery 11.1V 2200mAh 30C 18650 li-ion lithium ion battery pack for aircraft UAV
- Yinshan DETA battery 7OPzV490 industrial emergency 2V490AH electric fire protection/energy storage
- German Ginkgo DETA Colloidal Battery 8OPzV800 Sealed Liquid State Energy Storage and Generation System
- German DETA silver fir industrial grade battery 6OPzV600control backup battery for mining base stations
- 1080P H.264 Low Light USB Camera Industrial Varifocal Mini USB Webcam Camera
- German DETA silver fir colloid 5OPZV250 battery power battery screen USP power supply
- (DETA) Battery Silver cedar Battery 2VEL300 Lead Acid Battery Base Station
- German DEAT \ \ dryflex Ginkgo 6OPzV600 Solar EPS/UPS Power Supply
- Limit switch proximity /photoelectric switch
- German DETA Ginkgo UPS/EPS battery 10OPzV1000 maintenance free industrial
- DETA Yinshan Industrial Emergency 8OPzV800 Valve Regulated Lead Acid Battery in Germany
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
ATUL KHOSLA
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-