Home > Products > RECTIFIER TRANSFORMER > CHROME RECTIFIER
CHROME RECTIFIER
- 111 Unit / Units per Month
- mumbai
- T/T L/C D/P D/A
- Acrel ABAT-S battery-powered module device for Battery Monitoring System less than 13mA (1.2V&2V) or 7mA(6V&12V)quiescent
- Acrel ABAT-S battery analyzer monitoring system On-line monitoring of the voltage internal resistance of each backup battery
- Acrel ABAT-C Battery Monitoring Module Lead Battery Charge Discharge output 4-20mA
- Acrel ABAT Battery Monitoring System used for Base Station for 2V/6V/12V Lead Acid Batteries with RS485 communication
- Acrel ABAT-S battery analyzer monitoring system Interfaces with most UPS controller
- Acrel ABAT-S Lead-acid module device per battery to monitor internal resistance voltage and temperature
Product Details
Place of Origin: | Gujarat, India | Brand Name: | PEC | Model Number: | 100 KW |
Product Description
CONSTRUCTION : The quoted Rectifier equipment will be in Three parts construction
- Voltage Regulator – will be in housed in separate tank.
- Main Transformer with IPT & Diodes
- Control Panel
RECTIFIER EQUIPMENT PRIMARILY CONSISTS OF THE FOLLOWING:
1). Linear, Plus / Minus type Vertical Rolling Contact Voltage Regulator:
In our regulator we are using heavy section of electrolytic grade rectangular copper strip instead of copper wire to minimize the losses & increase the efficiency of equipment. We are also using self Lubricating Carbon Roller Assemblies instead of ordinary carbon brushes which offers more reliability and trouble free performance of the equipment.
- The output DC voltage variation is step less by means of ON LOAD motorised regulator. We use vertical ROLLING CONTACT TYPE voltage regulator, wound with heavy section of copper strip, suitable for 100% continuous duty cycle. The life of these regulators is more than 25 years and have 4 - 5 % better efficiency in comparison to conventional dimmerstat type regulators.
- Please note that Rectifiers manufactured by us, we are using plus/minus type (+ 254 Volts OR + 440 Volts) Voltage regulator in "Q" connection - which means that the capacity of voltage regulator required in our Rectifier winding design is 50% in Star connected (+ 254 Volts) model and 30% in Delta connected (+440 Volts) than straight type (0-440 Volts) voltage regulator used by conventional design rectifier winding.
- With Plus/Minus type voltage regulator used in our rectifier design, the capacity of Voltage Regulator used remains the same, but the brush current of the Regulator reduces and the reliability of regulator increases. This results in considerable saving in overall power losses of our Rectifier equipment.
2.) MAIN TRANSFORMER WITH IPT & DIODES
- CORE : In our transformer we are using CRGO lamination to minimize iron losses. The core is constructed from low loss, Cold rolled, grain oriented, annealed laminations of electrical sheet steel conforming to the latest international standards. Special frame is built in house for clamping the core to reduce the magnetic noise as well as making the whole structure rigid and robust. We are using CRGOLSSS of M3 Grade.
- WINDINGS: Coil are wound with paper covered electrolytic grade copper strip or synthetic enameled copper conductors. Cooling ducts are provided to keep the hot spot temperature as low as possible. Rigid connection support and coil clamping is provided to ensure high short circuit strength. Electrolytic Grade Copper or Synthetic enameled copper with Parallel winding on the Sec. side to reduce the SKIN effect. Make : HCL supplied by Harinam Wires.( As per I.S. 2026).
Contact Us
- POWER ENGINEERS COMPANY
- Contact nameATUL KHOSLA
- Phone91-9714-777713
- Address967/2/2, GIDC, MAKARPURA,
- Overhead Line High Voltage Line fault locator Device
- earth fault indicator distribution system
- big diameter welded steel tube
- wind tower pole
- substation steel structure
- monopole steel tower
- power transmission line steel tower
- Electrical equipment frequency converter
- Vector Frequencyinverter
- Overhead power line fault indicator with Three color light display
- short circuit and earth fault indicator distribution system
- Current Temperature And Faults On-line Monitoring instrument
- how to reset overhead line earth fault indicator
- Electric Power Overhead type Cable Fault Indicator
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Installation adapter of Overhead Line Fault Indicator
- short circuit and earth fault passage indicator with good price
Popular Searches
Recommended Products
- ITT DPXMA/ME (ARINC 404) CONNECTOR DPKA-18SG-7-F0
- 40135 20.5Ah 3.2V lifepo4 battery for BOATS Golf Carts
- SAFRAN CIRCUIT BREAKER 700-001-10
- 33140 15Ah 12.5Ah 3.2V lifepo4 battery for power bank power station
- Vector Inverter VFD Frequency Converter 3 Phase Variable Frequency Drive Motor Speed Control AC DC inverter 50hz to 60hz 55KW
- General Used Vector Control Frequency Inverter(3phase 380V) 200kw
- 37kw 380v~400v frequency inverter 3phase input and 3phase output with ce certificate
- 6.5kw ~ 1000kw Stamford AC 3phase Electric Alternator for Diesel Gensets
- 280kw to 2000kw Diesel Power Electric Generator Powered by Baudouin for Industrial Use
- 15kw to 120kw Pto Generator Drived by Tractor
- 26700 3.2V 4000mAh 4500mah 5000mAh 6000mAh Lithium Iron Phosphate Battery
- SAFRAN CIRCUIT BREAKER 4200 series
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
ATUL KHOSLA
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-