Home > Industrial Equipment & Components > Refrigeration Equipment > Industrial Air Conditioner > Industrial Heat Pump Water Heater Air to Water

Industrial Heat Pump Water Heater Air to Water

Industrial Heat Pump Water Heater Air to Water photo-1
US$ 500 - 3,000 MOQ: 1 Set
Key Specifications
Get Latest Price
Place of Origin:
Guangdong, China
Brand Name:
Macon
Model Number:
MAHRW060ZB/(P)S
Payment & Shipping
Payment Methods:
Port of Shipment:
Shunde Guangzhou
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Guangdong, China
Brand Name Macon
Model Number MAHRW060ZB/(P)S
Type Other, Heating, air source multi-function heat pump

Specifications

Industrial heat pump water heater
1.Function:hot water,heating,cooling
2.Heating capacity:7.5--75KW
3.COP:4.2
4.CE,RoHS

  Air to water heat pump water heater  

 

Model 1 MAHRW 030ZB/(P) 040ZB/(P) 050ZB/(P)S 060ZB/(P)S
Model 2 MAHRW 030ZB/(P)(E) 040ZB/(P)(E) 050ZB/(P)S(E) 060ZB/(P)S(E)
Rated Output Water L/h 225 300 375 450
Heating Capacity(1) kW 10.5 14.0 17.5 21.0
BTU/h 35900 47800 59800 71700
COP(1) W/W 3.6 3.6 3.6 3.6
Input Power(1) kW 2.92 3.89 4.86 5.83
Input Current(1) A 13.3 17.7 7.4 8.9
Heating Capacity(2) kW 9.0 12.0 15.0 18.0
BTU/h 30800 41000 51200 61500
COP(2) W/W 3.26 3.26 3.26 3.26
Input Power(2) kW 2.76 3.68 4.60 5.52
Input Current(2) A 12.5 16.7 7.0 8.4
Heating Capacity(3) kW 9.6 12.8 16.0 19.2
BTU/h 32800 43700 54600 65600
COP(3) W/W 4.12 4.12 4.12 4.12
Input Power(3) kW 2.33 3.11 3.88 4.66
Input Current(3) A 10.6 14.1 5.9 7.1
Rated Temp.Of Water Output °C 55
Power Supply V/PH/Hz 220/1/50 220/1/50 380/3/50 380/3/50
Noise dB(A) 52 54 54 55
Compressor   Scroll Scroll Scroll Scroll
Compressor Qty   1 1 1 1
Fan Qty   1 1 1 1
Fan Direction   vertical vertical vertical vertical
Water Flow Volume m3/h 2 2.5 3 3.5
Water Out let/Water In let inch 1 1 1 1
Refrigerant Type   R410A/R407C/R134a
Unit Net Dimensions ( L/M/H ) mm 760/704/770 860806/970 860/806/970 860/806/970
Unit Shipping Dimensions ( L/M/H ) mm 785/770/870 890/870/1070 890/870/1070 890/870/1070
Net Weight kg 80 95 115 120
Shipping Weight kg 95 110 130 135
Note:
(1)Heating:Outdoor air temp:20°C/15°C,water tank water temperature from15°C heating to 55°C
;
(2)
Heating:Outdoor air temp
:7°C/6°C,Outlet water temp:45°C,Input water temp:40°C
;
(3)
Heating:Outdoor air temp
:7°C/6°C,Outlet water temp:35°C,Input water temp:30°C
;
(4)Model 1 Using in ambient temperature:-15
°C~43
°C;
(4)Model 2 (EVI Technology) Using in ambient temperature:-25°C~43°C.

 

 

 

 

 

Wide application

The modular structure is the best choice and suitable for various sizes of engineering, office buildings, hotels, restaurants, cinema, shopping plaza, gymnasium, various public hospital ect.

 

Multistage energy regulation

According to different load flexible use of multistage energy regulation.

 

High efficiency and energy saving

Using high-efficient compressor rotary or scroll and heat exchanger, small volume,strong  heat enchange capacity, up 10% than the same old units.

 

Multi-protect and reliable

Unit   protection against freezing, compressor high-pressure compressor, high and low voltage protection, compressor overtemperature, compressors flow, power supply phase sequence,ensure unit works in hash environment.

 

Optional for integral type and split type, and easy to installation

Built  in WILO pumps, flow switches, easy to install pipe connections, especially in split type design, take water system entirely in indoor, completely solved the problem of the water system freezing in cold weather,, particularly suitable for cold areas.

 

Air to Water Heat Pump

It is EVI design for 60oC higher water temperature, especially for the extremely cold area, like -25oC ambient temperature; Its core philosophy is to solve the house heating during the cold climate in Winter and Spring and make room cooling in hot Summer and Autumn. This kind of design can do not only heating and cooling but also can provide sanitary hot water all over the year because the second circle heating can use 60oC hot water to heat the 10~15 oC tap water to 55 ~60 oC sanitary water. So it is realized to offer heating,cooling and sanitary hot water with only one heat pump.

 

The heat pump performance has been improved greatly with Copeland new designed EVI compressor from the United States Emerson Ltd and with MACON specially designed economizer and high efficiency heat transfer module.With six months of performance testing and validation in the different conditions of Multifunctions Lab.,the EVI Series Heat Pump has reached the COP=4.2  for floor heating mode (EN14511-2007) and it is available for 60 oC hot water output and safely working in -25 oC ambient temperature.

 

1. Higher Water Temperature Output up to 60oC
2. Safely Working Temperature Down to: -25oC

3. High Efficiency COP up to 4.2 (EN14511-2007)

4. Three in One : Heating, Cooling and Sanitary Hot Water

Industrial heat pump water heater air to water

Industrial heat pump water heater air to water

 

 

Industrial heat pump water heater air to water

Industrial heat pump water heater air to water

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer, Trading Company
Year Established
2007
Factory Size
10,000-30,000 square meters
Total Employees
101 - 200 People