Home > Electrical & Electronics > Sensor > Pressure Sensor > New! ETCR068C Clamp Current Sensor

New! ETCR068C Clamp Current Sensor

New! ETCR068C Clamp Current Sensor photo-1
US$ 45.9 - 65.57 MOQ: 1 Piece
Key Specifications
Get Latest Price
Place of Origin:
Guangdong, China
Brand Name:
ETCR
Model Number:
ETCR068C
Payment & Shipping
Payment Methods:
Port of Shipment:
Guangzhou
Delivery Detail:
Delivery time depends on order quantity.
Place of Origin Guangdong, China
Brand Name ETCR
Model Number ETCR068C
Usage Other, Current sensor
Theory Current Sensor
Output Switching Transducer

Specifications

Clamp Current Sensor
1.Range: AC 0.0A~2000A,
2.Resolution:0.1A
3.Clamp size:68mm

ETCR068C   Clamp Current Sensor  

Model:ETCR068C
Name:    Clamp Current Sensor
Features: CT clamp, measurement range: AC 0.0A~2000A, insolution:0.1A, clamp size:Φ68mm, current common reactance output. The highest accuracy level: 1.0 coil taps directly.
Introduction

ETCR068C Clamp Current Sensor applies to measure AC current, phase, power energy, power, power factor. Adopt last CT technology. It is portable, large clamp design, no need to disconnect the measured circuits, non-contact, safe and fast. It can be connected with phase detection analyzer, industrial control equipment, data recorder, oscilloscope, harmonic analyzer, electric power quality analyzer, high precision digital multi-meter, etc.Widely use in electricity, communication, meteorology, mining enterprises.

ETCR068B can be used to test AC strong current and it is cheap.

 
Technical Specifications
 
 

Function

Measurement of AC current, phase, power energy, power, power factor, etc.

Test mode

Clamp CT

Clamp Size

Φ68mm

Range

0.0A~2000A AC

Resolution

0.1A

Accuracy

±2.0%FS(50Hz/60Hz; 23°C±2°C, below 70%RH, keep the wire be in the center of clamp)

Coils Turn

Standard 2400:1(customize is allowed)

Phase Error

≤3°(50Hz/60Hz; 23°C±2°C)

Reference Load

RL:0~200mA≤2kΩ; 0~20A≤20Ω; 0~2000A≤0.2Ω

Shield

Clamp without shield layer

Output Mode

Current induction output

Output Interface

2thread or chose the standard probe of multi-meter

Output Wire Length

2m

Electric Field Interference

About 0.3A when the external electric field 100A, 10mm nearby, without shield layer.

Measured Wire Position

Approximately in the geometric center of the clamp

Current Frequency

45Hz~60Hz

Frequency

40Hz~75Hz

Voltage of circuit

Circuit with the voltage below AC 600V

Dimension

185mm×115mm×43mm

Weight

530g

Working Environment

-20°C~50°C;80%rh below

Storage Environment

-10°C~60°C;70%rh below

Insulation Strength

AC 3700V/rms. (between core and shell)

Safety Rules

IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT(600V)

Accessory

Sensor:1pc

 

 
 
Structure Drawing

 

 

 

New! ETCR068C Clamp Current Sensor

1. Coil tap input       2.Coil tap output       3.Sensor output pin (2m)

4. Clamp             5.Trigger. (Control the clamp)

 

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Manufacturer
Year Established
2006
Factory Size
Below 1,000 square meters
Total Employees
51 - 100 People