Home > Products > Photovoltaic Surge Protection Device > Uc 800V DC Photovoltaic Solar Energy Lightning Arrester
Uc 800V DC Photovoltaic Solar Energy Lightning Arrester
- 50000 Set / Sets per Month
- Conton/shanghai
- T/T L/C D/P D/A Credit Card
Product Details
Place of Origin: | Hunan, China | Brand Name: | ZHONGPU SHENGDE | Model Number: | DXH06-F/3DC600R40 |
Product Description
1. APPLICATION
Designed especially for surge protection of the PV strings; apply to the PV power grid-connection system.
2.TECHNICALS PARAMETERS
Model DXH06-F/ | 3DC1000R40 | 3DC800R40 | 3DC600R40 | |
Type (IEC 61643-1) | Class II /Type 2 | |||
Max. Continuous Operating Voltage(Uc) | 1300VDC | 1000VDC | 800VDC | |
Nominal Continuous Operating Voltage(Un) | 1000VDC | 800VDC | 600VDC | |
Nominal Discharge Current Capacity (In) | 20kA(8/20μs) | |||
Max. Discharge Current Capacity (Imax) | 40kA(8/20μs) | |||
Protection Mode | Full Mode Protection | |||
Protection Level(Up) | ≤4.0kv | ≤3.6kv | ≤3.2kv | |
Response Time(T) | <25ns | |||
Fault Indicator | Available | |||
Live Line(mm² ) | ≥6 | |||
Earth line(mm² ) | ≥10 | |||
Grounding Resistance(R) | ≤4Ω | |||
Protection Level of the Shell | IP20 | |||
Operating Temperature | -40℃~+70℃ | |||
Overall Size(mm) | 54×90×65 | |||
Installation Method | 35 mm DIN-rail |
3.NAMING RULES:
4. WIRING DIAGRAM
5.Main Features:
l Use Y-shaped connection, Full mode protection of the L+-L-/PE;
l Use the temperature control circuit break protection technology,to avoid the accident;
l With the remote alarm contact signal, convenient to remote monitoring of the system;
l The module has normal and fault indication, with fast response speed and low residual voltage.
6.Installation Method and Attentions
1) Wiring as shown in Figure;
2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;
3) The front of lightning arrester shall be connected with proper fuse in series or be opened;
4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;
5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;
6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;
7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.
7. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park Zhuzhou,Hunan
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
- 6ES7223-1PL32-0XB0 SIMATIC S7-1200 SM 1223 digital input output modules PLC module
- Siemens plc 6ES7 321-1BH02-0AA0 SIMATIC S7-300 Digital input SM 321 6ES73211BH020AA0
- 6ES73211BH020AA0 simen plc S7-1200 I/O module 6ES7321-1BH02-0AA0
- Original ABB TU838 3BSE008572R1 module
- Original ABB 3BSE038415R1 AO810V2 Analog Output 8 ch I/O Modules
- ABB PROFIBUS module CI840A 3BSE041882R1 PROFIBUS DP-V1
- Servo high temperature vacuum hot press Electric cylinder high pressure and high precision vacuum press 450 degrees Celsius, 5 tons, 10 tons
- HAILUNDA GZC-TF21 15.6 inch screen vacuum laminating machine OCA optical glue vacuum pressing machine
- PIONEER MAGNETICS PM3398B-6-1-3-E 80026-172-24 Digital input I/O module
- EMERSON A6740 RELAY MODULE
- EMERSON A6410 Expansion monitoring module
- EMERSON A6210 Axis vibration monitoring card
- EMERSON A6220 monitor module
- EMERSON A6110 Low pressure differential regulator
- GE 369-HI-R-M-F-E-H-E Motor management relay
- VIBRO-METER VM600 RPS6U 200-582-600-013 SCR module
- VIBRO-METER VM600 RLC16 200-570-000-111 200-570-101-015 Relay card
- VIBRO-METER VM600 MPC4 200-510-071-113 200-510-111-034 MPC4 Mechanical Protection Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOCN 200-566-000-112 200-566-101-013 IOCN Card
- VIBRO-METER VM600 IOC16T 200-565-000-013 200-565-101-013 I/O module
- VIBRO-METER VM600 IOC4T 200-560-000-111 200-560-101-017 Vibration monitoring and protection system
- VIBRO-METER VM600 CPUM 200-595-067-114 Central processing unit module
- VIBRO-METER VM600 CMC16 200-530-025-014 200-530-111-013 Condition monitoring
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Recommended Products
- Spain VENTURA battery powered GPL12-75 battery UPS/EPS host maintenance free
- Spain Ventura Battery GPL12-55 Ship Equipment UPS/EPS Backup
- UNITROL1020 3BHE030579R0003 Voltage regulator Can automatically monitor and adjust voltage
- DPO5054B Mixed signal oscilloscope Real-time sampling rate up to 10 GS/s on two channels
- ARND-3115 A 18 Vibration monitoring module Monitoring rotating equipment in chemical plants and manufacturing
- XVB603 6U-VME-SBC 6U CompactPCI board Real-time control and communication tasks
- T8110B Trusted TMR processor module Fault-tolerant design with three-mode redundancy
- CMR-HB4A0450ABC High performance module Provides reliable and efficient motor control
- PM866A 3BSE076359 Communication module Implement communication between devices
- HIEE205011R0002 Programmable controller The processing speed reaches 230μs
- BUM61-20/30-54-B-O-12 Motor control module Advanced control algorithm is adopted
- 810-102361-222 Rocker arm valve interface board The valve is under positive voltage
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-