1. APPLICATION
Designed especially for surge protection of the PV strings; apply to the PV power grid-connection system.
2.TECHNICALS PARAMETERS
Model DXH06-F/ | 3DC1000R40 | 3DC800R40 | 3DC600R40 | |
Type (IEC 61643-1) | Class II /Type 2 | |||
Max. Continuous Operating Voltage(Uc) | 1300VDC | 1000VDC | 800VDC | |
Nominal Continuous Operating Voltage(Un) | 1000VDC | 800VDC | 600VDC | |
Nominal Discharge Current Capacity (In) | 20kA(8/20μs) | |||
Max. Discharge Current Capacity (Imax) | 40kA(8/20μs) | |||
Protection Mode | Full Mode Protection | |||
Protection Level(Up) | ≤4.0kv | ≤3.6kv | ≤3.2kv | |
Response Time(T) | <25ns | |||
Fault Indicator | Available | |||
Live Line(mm² ) | ≥6 | |||
Earth line(mm² ) | ≥10 | |||
Grounding Resistance(R) | ≤4Ω | |||
Protection Level of the Shell | IP20 | |||
Operating Temperature | -40℃~+70℃ | |||
Overall Size(mm) | 54×90×65 | |||
Installation Method | 35 mm DIN-rail |
3. WIRING DIAGRAM
4.Main Features:
l Use Y-shaped connection, Full mode protection of the L+-L-/PE;
l Use the temperature control circuit break protection technology,to avoid the accident;
l With the remote alarm contact signal, convenient to remote monitoring of the system;
l The module has normal and fault indication, with fast response speed and low residual voltage.
5.Installation Method and Attentions
1) Wiring as shown in Figure;
2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;
3) The front of lightning arrester shall be connected with proper fuse in series or be opened;
4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;
5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;
6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;
7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.
6. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park Zhuzhou,Hunan
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
- ABB 5SHY3545L0014 Six axis sensor
- GE VMIC VMIVME-7740-850 350-007740-850 L Microcontroller module
- ABB 5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101 thyristor module
- BENTLY 3500/25 125792-01 Digital quantity control board module
- ABB UFC762AE101 3BHE006412R0101 Electrical control module
- NI GPIB-140A Fiber optic GPIB extender
- VIBRO-METER VM600 RPS6U 200-582-200-011 Vibration detection module
- VIBRO-METER 200-570-000-014 200-570-101-013 VM600 output module
- VIBRO-METER 200-560-000-018 200-560-101-015 VM600 IOC4T communication module
- ICS TRIPLEX T8110B Digital input module
- GE 04220FL11232A communication module
- FOXBORO FCP270 P0917YZ Control processor module
- BENTLY 3500/22M 288055-01 Transient Data Interface Module
- ABB XVC768115 3BHB7211R115 Input output module
- ABB UNITROL 1005-0011 ECO 3BHE043576R0011 Hybrid firmware chip module
- ABB PCD235B1101 3BHE032025R1101 Digital Output Module
- GE IS220UCSAH1A Control pulse module
- EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X022 Sensor module
Popular Searches
- lightning conductor
- Copper Lightning Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
- earthing material
- Clad Steel Ground Rod
Recommended Products
- ABB 5SHY3545L0014 Six axis sensor
- GE VMIC VMIVME-7740-850 350-007740-850 L Microcontroller module
- ABB 5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101 thyristor module
- BENTLY 3500/25 125792-01 Digital quantity control board module
- ABB UFC762AE101 3BHE006412R0101 Electrical control module
- NI GPIB-140A Fiber optic GPIB extender
- VIBRO-METER VM600 RPS6U 200-582-200-011 Vibration detection module
- VIBRO-METER 200-570-000-014 200-570-101-013 VM600 output module
- VIBRO-METER 200-560-000-018 200-560-101-015 VM600 IOC4T communication module
- ICS TRIPLEX T8110B Digital input module
- GE 04220FL11232A communication module
- FOXBORO FCP270 P0917YZ Control processor module
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-