Home > Products > Applications > LZCK 310-10 outdoors openable current transformer
LZCK 310-10 outdoors openable current transformer
- 100000 Piece / Pieces per Month
- Beijing Shenzhen HK
- T/T Credit Card
You May Like
-
GFUVE GF312B Portable three phase energy meter tester with printer
-
GF2013 amp clamp meter
-
Electricity meter testing equipment GFUVE GF102 single phase energy meter testing set
-
GF102 Single Phase Energy Testing Equipment with phantom load
-
Energy Meter test equipment GF302D Portable Three-Phase kwh multimeter calibrator
-
GFUVE GF333V2 Portable Multifunction Energy Meter tester
Product Details
Place of Origin | Beijing, China | Brand Name | GFUVE | |
Model Number | LZCK310-10 | Usage | Current | |
Phase | Single | Coil Structure | Toroidal | |
Coil Number | Autotransformer |
Product Description
Specifications
Split core current transformerISO and CE approved
Indoor or outdoor
OEM offered
Accuracy class 0.2, 0.2S, 0.5, 0.5S, 1
LZCK310-10 Split Core Current Transformer
LZCK Split Core current transformer is suitable for current measurement and microcomputer protection of distribution equipments in 10KV or 35KV AC power system. It is widely used in not only compact full insulated ring net switchgears such as ABB-SafeRing/SafePlus, Uniswitch, Schneider RM6, SM6, Siemens 8DJ10/8DH10, Simosec, FBX, Fluokit, Omar Garbo GA, GAE; SEL TPS(Q); VEI Unifluorc; Eaton SVS/12 ring network, but also cable distribution boxes because of its small size, light weight, open feasibility and convenient installment. It is very convenient that the transformer can be directly installed at connected output and input cables.
High quality silicon steel sheet metal slug with very high magnetic permeability as transmit magnetism material are used in the measuring winging of LZCK current transformer, so its core can be divieded and the magnetic circuit loss is little. The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin is the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance
The two half cirque of the current transformer encircle the split phase cable tightly and uniformly. It has two configuration formats of single ratio and double ratios and two Installation modes of plastic waistband and stainless steel waistband, and it is applicable to all the 35mm2-400mm2and 10KV or 35KV cables.
The current transformers can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding parameter tables of every type.
Technical data
Rated ratio accuracy class and ratedloadas the following table:
Type | LZCK310-10 | LZCK310-10 | ||||
Purpose | Measuring current transformer | Protection current transformer | ||||
Ratio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | ||||
I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 |
300/1 | 1.5 | 2.5 | 2.5 |
| 1.5 | 2.5 |
400/1 | 2.5 | 3.75 | 3.75 |
| 1.5 | 2.5 |
500/1 | 2.5 | 5 | 5 | 1.5 | 2.5 | 5 |
600/1 | 2.5 | 5 | 5 | 1.5 | 2.5 | 5 |
300/5 | 2.5 | 3.75 | 3.75 |
| 1 | 2.5 |
400/5 | 5 | 7.5 | 7.5 |
| 1.5 | 3.75 |
500/5 | 5 | 7.5 | 7.5 |
| 2.5 | 5 |
600/5 | 5 | 7.5 | 10 |
| 2.5 | 5 |
ZCK Split core current transformer: 1A, 5A or 10A. Secondary winding could be tapped when necessary, namely multi-current-ratio trans-former.
Operating conditions
Environmental temperature: -35℃ ~ +55℃,daily average: up to : +40℃
Altitude: up to 3500 meters
No existence of severely begrimed, erosive and radioactive air in the atmosphere
Permission of long-term operation under rated current
P1, P2 denotes primary terminal, S1, S2 denote secondary polarity terminals.
P2, S2 denote homonymous terminals (subtractive polarity).
Technical data
Rated: 50Hz or 60Hz
Rated secondary current: 5A or 1A
Rated short-time thermal current: 40kA, 1S
Rated continuous thermal current: 120%I 1n
Continuous power-frequency voltage: 3kV, 1min
Instrument security factor: FS≤10
Standards: IEC60044-1; IEC 61869-2;NTC 2205; GB1208-2006
Wiring diagrams
Single winding Secondary winding with aninter-mediate tapping Double winding
Ordering instruction
Be sure to indicate model, current ratio, accuracy class, rated load and use of the products when designing, lectotype or purchase. Special specifications could be customized.
All kinds of current transformers of different specifications and parameters can be made according to the client’s demands.