Home > Products > ELISA test > infectious dieases EIA HBV HBsAg Elisa test kit
infectious dieases EIA HBV HBsAg Elisa test kit
- 10000 Box / Boxes per Month
- tianjin or beijing
- T/T Credit Card PayPal
- Daxin New Muti-fuction Baby TE-79Infrared thermometer
- daxin Infrared Ear Thermometer TE-82 Infrared thermometer
- TE-105 Universal Smartphone Forehead Mini Thermometer
- TE-101 Wall mounted Forehead thermometer
- KS-727 Folding Kitchen scale
- TE-66 Infrared thermometer Factory direct sales can be customized in bulk
Product Details
Type: | Blood Testing Equipments | Brand Name: | Bioneovan | Place of Origin: | Beijing, China |
Model Number: | in vitro diagnostic |
Product Description
Specifications
1.Double antibody sandwich EIA to detect Hepatitis B surface antigen2.Used for diagnosis of HBV infection
dical test kit
Certificate |
GMP |
SFDA |
ISO13485 |
ISO9001:2008 |
INTRODUCTION |
HBsAg ELISA is used for the qualitative determination of Hepatitis B surface antigen (HBsAg) in human serum or plasma. This test is indicated for the screening of blood and blood products to be used for transfusion and an aid for the diagnosis of existing or previous hepatitis B infection.
SUMMARY AND PRINCIPLE OF THE TEST |
Hepatitis B is an infectious illness caused by hepatitis B virus (HBV) which infects the liver of hominoidea, including humans, and causes an inflammationcalled hepatitis. HBV is excreted in body fluids such as semen, saliva, blood and urine in persons with acute or chronic infection. The hepatitis B virus is known as a blood-borne virus because it is transmitted from one person to another via blood or fluids contaminated with blood.
About 7.18% carry hepatitis B Virus surface antigen. About 93 million people are chronic carriers of HBV among which about 30 million are suffering Hepatitis B around the country. Transmission of hepatitis B virus results from exposure to infectious blood or body fluids.
When HBV invades the body it causes liver damage through induction of auto-immunity. Three immunity has been found, surface antigen (HBsAg)/HBsAb, core antigen (HBcAg)/HBcAb and e antigen(HBeAg)/HBeAb. As it is difficult to detect the core antigen in the serum, the other five are been done to diagnosing HBV. The surface antigen contains the determinant “a”, common to all known viral subtypes and immunologically distinguished in two distinct subgroups (ay and ad). HBV has 10 major serotypes and four HBsAg subtypes have been recognized (adw, ady, ayw, and ayr). HBsAg can be detected 2 to 4 weeks before the ALT levels become abnormal and 3 to 5 weeks before symptoms develop. The serological detection of HBsAg is a powerful method for the diagnosis and prevention of HBV infection and ELISA has become an extensively used analytical system for screening of blood donors and clinical diagnosis of HBV in infected individuals
PRINCIPLE OF THE ASSAY |
The HBsAg EIA is a solid-phase simultaneous sandwich immunoassay, which employs monoclonal antibodies and polyclonal antibodies specific for HBsAg. Microtiter well is coated with monoclonal antibodies specific for HBsAg. A serum specimen is added to the antibody coated Microtiter wells together with enzyme conjugated polyclonal antibodies. HBsAg, if present, will form an antibody-HBsAg-antibody-enzyme complex. The plate is then washed to remove unbound material. Finally, a solution of substrate is added to the wells and incubated. A blue color will develop in proportion to the amount of HBsAg present in the specimen. The enzyme-substrate reaction can be stopped and the result is visualized by naked eye or read by EIA plate reader for absorbance at the wavelength of 450 nm(450 nm/630 nm) and is proportional to the amount of antibodies present in the specimen..
Materials required but not provided:
- Precision pipettes: 0.02, 0.05, 0.10, 0.15, 0.20, and 1.0 ml.
- Disposable pipette tips.
- Distilled water.
- HumidifiedBox capable of maintaining 37°C
- Absorbent paper or paper towel.
- Microtiter plate or strip-well washer
- Microtiter plate reader with 450nm (or 450 nm/630 nm)wavelength
- Timer
SPECIMEN COLLECTION AND PREPARATION |
Serum should be prepared from a whole blood specimen obtained by acceptable medical techniques. Either serum or plasma can be used in this test. Remove serum or plasma from the clot or blood cells as soon as possible to avoid hemolysis. Specimen with extensive particulate should be clarified by centrifugation prior to use. Specimen frozen at -20°C or colder may be used. Avoid repeated freeze thaw.
PRECAUTIONS FOR USERS |
- For in-vitro diagnostic use only.
- Do not use kit beyond expiration date.
- Do not mix components from kits with different lot number.
- Avoid microbial contamination of reagents.
- Do not pipet reagent by mouth and no smoking or eating while performing assays.
- Wear gloves during the whole process and avoid reagents or specimen spilling-out.
- Wipe up the spills using 5% hypochlorite solution.
- Decontaminate all liquids or solid wastes before deposing.
STORAGE OF TEST KITS |
Unopened test kits should be stored at 2-8°C. DO NOT FREEZE KIT COMPONNETS. The microtiter plate should be kept in a sealed bag to minimize exposure to damp air. Use up the reagents as soon as possible after the kit is unpacked.
WORKING WASH BUFFER |
Dilute the 20X wash buffer concentrate with deionized or distilled water 1:20. For example, 5 ml of wash buffer concentrate should be diluted to a total volume of 100 mL with deionized or distilled water.
ASSAY PROCEDURE: |
It is strongly advised to analyze each specimen and controls in duplicate. All the reagents should equilibrate to room temperature before use.
- Dispense one drop (100μl) of Positive Control as well as Negative Control in duplicate into respective wells. Set one blank well as background control, and 100ul of serum or plasma samples into respective test wells.
- Place the microtiter plates into a humidified box, and incubate at 37°C for 60 minutes.
- Add one drop (50μl) of Enzyme Conjugate to each well. Mix it gently by swirling the microtiter plate on flat bench for 1 minute. Do not add Enzyme Conjugate to the blank well.
- Place the microtiter plates into a humidified box, and incubate at 37°C for 30 minutes.
- Wash each well 5 times by filling each well with diluted wash buffer, then inverting the plate vigorously to get all water out and blocking the rim of wells on absorbent paper for a few seconds.
- Add one drop (50μl) of Substrate Solution A (HRP-substrate) to each well, then add one drop (50μl) of Substrate Solution B (TMB) to each well. Mix gently and incubate at 37°C for 30minutes.
- Add 1 drop (50μl) of Stop Solution to each well to stop the color reaction. Read the OD value at 450 nm/630 nm with dual filter plate reader. It is option to read the OD value at 450 nm with single filter plate reader. (using the OD value of the blank well to correct all the OD reading from all wells)
Contact Us
- Bioneovan Co., Ltd.
- Contact nameSteven Tan
- Phone86-010-69255832
- AddressNo. 18, Keyuan Road, Industry Development Zone
ELISA test | New Products |
- TE-109 Infrared thermometer Factory direct sales can be customized in bulk
- Fingertip Oximeters New Arrivals Factory direct sales can be customized in bulk
- blood pressure monitor EPA-46B4-04 digital blood pressure monitor
- Medical Grade Thermometer for Adults Heavy Duty Forehead Thermometer for Adults and Kids Clinical Accurate Digital Thermometer Touchless 32 Memory Body & Surface Mode Support customizable
- 12 Channels ECG Machine, 3 Channel Electrocardiograph, 6 Channel ECG
- Multi-function comprehensive inspection bed
- Pipettes - Laboratory pipettes
- Urine Analyzer
- ESR Analyzer Fully automatic erythrocyte sedimentation rate analyzer
- Microplate Washer
- Coagulation Analyzer
- vacuum tube
Popular Searches
- Combo Test
- home health care
- stethoscope id tag
- Silicone Stethoscope Cover
- stethoscope tag
- wholesale stethoscope id tags
- stethoscope name tag
- Screen Test
- freestyle lite strips
- Mercury Glass Rectal Thermometer
- ph test kits
- accu-chek active blood glucose meter
- oval clinical thermometer
- name tag for stethoscope
- sprague rappaport type stethoscope
- littmann stethoscope classic
Recommended Products
- automatic light inspection machine for liquid drugs
- lyophilized powders ,vial , glass ampoule cleaning machine
- lyophilized powders ,vial , glass ampoule leak detection machine
- AVI tablet capsule visual inspection machine
- AVI ampoule visual inspection machine
- Professional Biphasic Aed Manual External Defibrillator Prevent Inadvertent Defibrillation
- First-aid Portable Aed Automatic External Defibrillator
- Portable Automatic External Defibrillator AED
- AED Machine Cardiac Defibrillator/ First Aid Automated External Defibrillator
- Full Digital cows Veterinary Ultrasound Scanner Machine Portable Vet Ultrasound Scan Machine For Animals
- Waterproof Handheld Ultrasonic Diagnostic Instrument Portable Vet Ultrasound Scanner For Animal
- Medical All Digital Animal Pregnancy Handheld Scanner Device Portable Veterinary Ultrasound Machine For Dog Cattle
Find Similar Products By Category
- Health & Medical > Medical Devices > General Assay & Diagnostic Apparatus
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Steven Tan
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-