Home > Products > Smart Home > Mobile Phone PDA GSM RC Wireless Remote Control Switch Socket
Mobile Phone PDA GSM RC Wireless Remote Control Switch Socket
- 10000 Piece / Pieces per Month
- shenzhen
- Credit Card
- 4holes RCA jack AV socket
- AV socket AV6 double-six-hole socket RCA jack video with metal
- Good quality single socket RCA as AV connector
- 4 holes jack socket RCA as AV connector
- Bluetooth 4.0 Wireless Anti lost alarm with Bluetooth Remote control for iPhone Samsung smartphone
- KDC-A04 Power Switch 4pin
Product Details
Place of Origin: | Guangdong, China | Brand Name: | BD | Model Number: | BD121201, SC1-GSM |
Type: | Wall Socket | Rated Voltage: | AC110v-220v | Rated Current: | 10A |
Application: | Commercial |
Product Description
Specifications
Mobile Phone PDA GSM RC Wireless Remote Control Switch SocketMobile Phone PDA GSM RC Wireless Remote Control Switch Socket
Description:
GSM switch is to use mobile phone calling and text to control the power socket on/off to operate the electrical appliances.
It works in any places with GSM signal available, except for 3G and CDMA card.
This product can only control the power supply switched on or off, do not have other functions.
Ideal Work with home and industrial electric appliances, like water heaters, electric motors, electric doors, lights, rice cookers, water pump, etc.
Application:
You can turn on/off radio,heating,lighting,server and other household appliances;also can cook rice;feed pets;etc.
Widely used in industry,such as water,oil,gas,acid and other all kinds of valve.
Features:
You can use phone rings or messages to the GSM switch to control the electrical appliances.
The device supports the 900/1800 frequency bands which is used in Europe.
You must enter password if want to operate and control it,ensure safety.
Socket control type:SMS/Dail/Button
Built-in microcomputer chip;it works in any places with GSM signal available,except for 3G or CDMA card.
Full of power off memory function to ensure electrical appliances continue to work after outages.
EU plug & universal socket offered;suitable for the different countries specifications of the plug.
Built-in GSM antenna;easy carrying.
Working range is within 110V—220V AC voltage, can not be used in cars, or other voltage environment.
Great to control home and industrial electric appliances,like water heaters,water pump,air-conditioning, electric doors, lights, etc.
CE ROSH certificate approved.
Specification:
Network: GSM
Frequency bands :900/1800MHz
Rated current: 10A
Rated Power: 2200W
Working voltage: AC110V-220V
Inherent power ≤ 0.2W
Dimension:3.94 in x 2.52 in x 1.26 in
Working temperrature:minus 15 to 65 Celsius
Package include:
1 x GSM switch (EU plug)
1 x User manual
How to use!!!
A: Basic setup and operation.
1. Install SIM card Installed your SIM card before power on, non-installed SIM card after power on!A short initialization time (20 seconds) after power on, related operations after initialization. GSM switch is disconnected by default.
2. Waiting for SIM card to connect the GSM network (according to local operators and signal level, usually about 1 minute to get into the network), and observe the SIG lights on the panel (the start is 1 second flash), when flash becomes 4 seconds, the proof has entered the GSM network, Then you can set and control the associated operation.
3. Set Password Must set up the user password first, GSM switch initial password is: 0000. Set Password command format: "SN +Four old password + NEW + Four new password. " For example, customers want set their passwords to : "1234", then he should edit the message content: "SN0000NEW1234" issued to GSM switch, if you set successfully, you will receive the message: "NEW SN SETOK NEW SN IS 1234 (New password). "The password with the power-down memory function.
4. Set master number GSMSW-A1 owners can set up 5 groups of master numbers, The seting format is: "SN +****(password) + SET + master numbers",send to the number of GSM switch, you can set the master numbers, such as the user's password is 1234, trying to set 13788889999 to master number, and then edit the message content: "SN1234SET13788889999" issued to GSM switch, if successfully,you will receive a message: "13788889999SETOK". Only the master number can control the outlet by dialing, when the master number dial number of GSM swithch, the switch status will change, and then hang up automatically after one second, does not produce any cost. master numbers with a power-down memory function.
5. Ringing to control Users control the GSM switch by dial the number of GSM switch, when get through the socket state change and hang up after 1 second. The user may hear "You can not answer the phone call, beep ... tone, etc., that set has been successful. If the switch is connected,it will change to disconnected state after a call.If the original state is off, call and changed to the connected.
B: SMS Control
1. SMS change switch status:Edit message "SN +****(passwords) + CHANGE "to sent to the GSM swithc, can change the status,when control is successful, GSM switch will return the current status. [For example: the password is 1234, edit text: SN1234CHANGE, sent to the GSM switch].
2. SMS check switch status: Edit message "SN +****(passwords) + CHECK "to sent to the GSM swithc, can change the state,when control is successful, GSM switch will return the current state. [For example: the password is 1234, edit text: SN1234CHECK, sent to the GSM switch].
3. SMS turn on switch: Edit message "SN +****(passwords) + ON "to sent to the GSM swithc, can change the state,when control is successful, GSM switch will return the current state.[For example: the password is 1234, edit text: SN1234ON, sent to the GSM switch].
4. SMS turn off switch: Edit message "SN +****(passwords) + OFF "to sent to the GSM swithc, can change the state,when control is successful, GSM switch will return the current state. For example: the password is 1234, edit text: SN1234OFF, sent to the GSM switch.
C: Key Control (GSMSW-A1 panel has two buttons, one is SW, one is SET.)
1. Control switch status When you press the SW button, switch state will be overturned. If the original state is connected, then turned off . If the original into Shutdown mode, GSM plug into connected.
2. Set master number When you press the SET button, the SIG lights will enter the flash state,about 90 seconds, The numbers plug into the GSM switch will be set to the master number during this time. When GSM switch during this period received a call comes in, it will hang up after 1 second call, and stop flashing SIG lights into the normal state,and new master number will be saved, with power-down memory.
3. Reset the system When the SW and the SET key pressing in the same time, reset the system. The system will restore the factory settings, STA lights flash slowly three times, 5 groups master numbers will be clear, the relay will enter the off state, the password also changed the factory code (0000).Set this function when the forgotten password or special circumstances (Note: must press two button in the same time, Otherwise, do not enter the rest).
*****Note*****
Install SIM card Installed your SIM card before power on, non-installed SIM card after power on.
SIM card requirements: global GSM standard SIM card can be used, currently does not support 3G or CDMA card,please activate the new SIM before insert the device
Caller ID display must be turned on,make sure that SIM card has sufficient balance to call and send text messages.
Please do not place the GSM switch in the tin trunk or metal enclosed environment, in case of affecting the actual use.
SMS or phone in the control,please don't to operate the buttons at the same time, avoiding system instability.
Ensure the GSM switch works with 110V-240AC voltage range and 2200W power,also can not be used in cars and other voltage environment.
To save time, once the dial socket after the success of GSM call will automatically hang up the number of the owner, the user may hear "Your call can not be answered , please hang up, beeps, etc. " is a normal situation.
Using the product should pay attention to moisture, limited to indoor use.
For some electrical appliances, such as some air-conditioning to maintain the function is not powered off, re-connect the power, will not immediately work. For the state to maintain electrical power, such as most of the TV, stereo can immediately work
Contact Us
- Shenzhen Bangdao Electronic Technology Co., Ltd.
- Contact nameJoJo liu
- Phone86-0755-83768255
- AddressRM305 ,21th Nanling South Road , Nanling,Buji,Longgang District, Shenzhen,China Shenzhen,Guangdong
Hot Selling | New Arrival | New Products | Smart DoorBell |
Smart GPS Tracker | Smart Home | Smart Security | Smart Sport |
Smart Wear |
- HDMI Microscope Sets HD 1080p 13MP 60F/S HDMI VGA Industrial Digital Microscope Camera
- Mini 60X Jeweler Loupe Magnifier Microscope UV Currency Detector with LED Light Jewelry tool
- Non-Fused Pullouts 30AMP/60AMP 240VAC Pull Out Switch
- Fused Pullouts 30AMP/60AMP 240VAC Pull Out Switch
- RV Panels with NEMA 14-50R / NEMA TT-30R/NEMA5-20R Outlet
- 30A RV lnlet Box with NEMA L14-30P/NEMA L5-30P PIug
- 50A RV lnlet Box with NEMA SS2-50P PIug
- HD 30x25 Monocular Telescope Zooming Focus Green Film Portable Optical
- 40X Handheld Magnifier Jeweler Appraisal LED Magnifying Glass Loupe with Light Leather Case (White) for Phone PCB Chip High-definition and Measure Tool
- HD 30X Magnifying Glass with Light and Stand, Dimmable 10-Diopter Real Glass Lens LED Magnifying Lamp
- 20A RV Panels with NEMA5-20R GFCI Outlet
- 30A RV Panels with NEMATT-30R / NEMA14-30R Outlet
- 50A RV Panels with NEMA6-50R Outlet
- 50A RV Panels with NEMA14-50R Outlet
- Maant 3D Infrared Thermal Imaging Analyzer for Phone PCB Motherboard Electrical Fault Diagnosis Inst
- MobIR Air Thermal Imaging Camera, Anti-peep Temperature Detection Thermal Imager Camcorder
- UTD2000L Series: UTD2025CL / UTD2052CL Digital Storage Oscilloscopes
- FNIRSI DSO-TC3 Digital Oscilloscope Portable Handheld 3 in 1 Diode LCR Transistor Tester
- Mechanical SIV120 Mini Portable Fully Automatic Electrician Multimeter Maintenance Measurement Instrument Built-in Lighting Lamp
- Mechanic MD5 Pen Multimeter Pen Type Meter Auto Range Digital Multimeter
- SUNSHINE DT-22AI Digital Multimeter with Touch Control for Phone Screen Repair
- UT139C True RMS Digital Multimeter PCB Fault Test Tool
- XZZ 20A Universal Test Lead Probe Extra Tip Multimeter Probe
- Digital TM-902C K-type LCD thermometer heat detector meter + thermocouple probe
Popular Searches
Recommended Products
- FOXBORO FBMSVH Control card module
- FOXBORO FBMSVL Multi port serial card
- ABB XVC770BE102 3BHE021083R0102 Thermal dispersion technology flow meter
- ABB XVC770AE 3BHE006414R0001 Servo Driver
- ABB PFEA113-65 3BSE050092R65 Dual expansion port module
- ABB LTC391AE01 HIEE401782R0001 connecting module
- ABB DSAI 130A 3BSE018292R1 Digital input/output module
- GE SR489-P5-HI-A20-E Protection Relay
- VIBRO-METER VM600 RPS6U 200-582-500-013 Vibration monitoring and control system
- HONEYWELL SPS5710 51199929-100 Power supply module
- GE IS210BPPBH2CAA Digital expansion module
- GE IS200TSVCH2AED MRP246517 Digital I/O module
Find Similar Products By Category
- Electrical Equipment & Supplies > Electrical Plugs & Sockets
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
JoJo liu
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-