Key Specifications
Get Latest Price
Type:
First-Aid Devices
Brand Name:
Foinoe
Model Number:
VT-1B
Payment & Shipping
Payment Methods:
Port of Shipment:
Shanghai/Nanjing
Delivery Detail:
Delivery time depends on order quantity.
Type First-Aid Devices
Brand Name Foinoe
Model Number VT-1B
Place of Origin Jiangsu, China

Vet hospital ventilator

Vet hospital ventilator 

Special Feature: 

1, CE Certificated

2, Alloy metal stents, spray technology, very durable

3, Stainless steel pressure monitoring gauge, the scope: 0-1Mpa, 0.05 scale readable.

4, Protective power switch and back-up power interface, effective to eliminate the accident happens.

5, New generation veterinary anesthesia ventilator design and architecture platforms

6, Professonal veterinary ventilator operation, some parameter could be set automatically.  

7, Adopt power supply rejection grid anti-jamming technology, more stable performance.

8, Good mobility performance,pass vibration test.

9, Easy operation, simple and clear.

10,International standard interface, could match with any anesthesia machine.

Technical Specification

1,Drive:Pneumatic driven and electrical control

2, Operation: Button

3,Sensor Type: Rotor sensor

4,Respiratory mode:IPPV,MAN

5,Tidal Volume:50~1600mL 

6, I:E: 1:2   BPM:3-40bpm

7,TV monitoring:20~300 mL,300 ~2000 mL 

8,Airway pressure monitoring:-20-100cmH2O

9Gas source gauge monitoring :0-1MPa

10Monitor:Inspiratory indicator,Expiratory indicator,Power indicator

11, Gauge:O2 one

12,Small animal bellows,TV:0~300mL

13Big animal bellows,TV:300~1600mL

Power supply requirement:

1,Power:220V,50HZ or 110V,60HZ
2,Input power: No more than 60VA
3,Maximum input current:5A
4,Main power entrance fuse: 250V  5A φ5X20(F)

Power cable:

1,Length:3 meter

2,Rated voltage:90 to 264V  AC

3,Maximum current:220 -240VAC 10A

4,Type: three-core cable (medical grade)

Environment requirement

Temperature

Operation:18-36℃  

Storage-20-55

Humidifier

Operation:45%-75%  

Storage: ≤93% Operation:    45%-75%   

 

 

 

Atmospheric pressure

Operation0.95~1.05 bar     

Storage:500hpa~1060hpa,

Altitude:Operation

Operation500 to 800 mmHg (3565 to -440m)

Storage:375 to 800 mmHg (5860 to -440m)

 

Size: 240mm(w)×370mm(H)×230mm(L) 

 

Other models for choice:  

Vet hospital ventilator

Vet hospital ventilatorVet hospital ventilatorVet hospital ventilator

 

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Year Established
2007
Factory Size
Below 1,000 square meters
Total Employees
11 - 50 People