- Zhuhai City Snova Technology Co., LTD
- China Manufacturer with main products:Earth Fault Indicator ,Cable Fault Indicator ,Overhead Line Ground Fault Indicator ,Short Circuit and Earth Fault Indicator ,Cable Temperature and Faults Sensor ,Industrial Dehumidifier ,Temperature and Humidity Controller ,Fault Passage Indicator ,Remote communication terminal ,Smart grid system
Home > Products > Short Circuit and Earth Fault Indicator > RTU for earth fault indicator
RTU for earth fault indicator
- 10000 Piece / Pieces per Month
- shenzhen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 15 days
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- Remote Wireless Communication Terminal for overhead grounding and short circuit fault
- Underground indicators Earth fault indicator for smart grid SNV-EFI
- Underground cables fault locator with big battery capacity 19000mHA EFIV2.0
- Surface Mounted Type SNV-EFI Earth Fault Indicator
- Grounding and short circuit fault indicator adjust alarm current by DIP
Product Details
Brand Name: | SNOVA | Place of Origin: | China | Model Number: | SNV309-EFI-IEC104/DNP3.0 RTU |
Product Description
RTU for earth fault indicator
II. Guidance for integrate process.
Ø Hardware parts connection and installation:
Ø IEC104& DNP3.0 RTU Parameter setting:
Ø SNV309-EFI, DNP3 Data Objects
Ø SNV309-EFI, IEC104 Data Objects
IV. Attachment for RTU Led blinking define:
User Manual
Products name: Grounding fault indicator RTU
Model: SNV309-EFI-IEC104/DNP3.0 RTU
Adapt for :
SNOVA ,SNV-EFI, Grounding Fault indicator and EKL series short Grounding fault and short circuit indicator, integrating into SCADA, via 2G/4G network.
I. General introduce.
SNOVA, Grounding fault indicator RTU, Version SNV309-EFI- IEC104/DNP3.0, it is professional used for SNOVA ,SNV-EFI, Grounding Fault indicator and EKL series short Grounding fault & short circuit indicator, integrating into SCADA, via 2G/4G network. And achieve the grid smart management.
It support both protocol of DNP3.0 and IEC104 at same time. User need not to do any changes on the device. It only need to choose different communication port in the user SCADA system. It can integrate by two SCADA system at same time.
II. Guidance for integrate process.Ø Hardware parts connection and installation:
Step 1:
Insert APN sim card into sim card slot (Note: Full size SIM card).
Step 2: Connect GPRS ANTENA on the case terminal.
Step3: Insert the Battery terminal on the PCB.
Step4: Connect Solar power cable via the Solar power panel.
Step5: Connect the EFI between RTU via cables according wiring scheme.
Ø IEC104& DNP3.0 RTU Parameter setting:
Using SNV308&SNV309 parameter setting APP via PC to set this parameter.
1. First connect RTU between computer via data cable.
2. Run the Parameter setting APP on PC.
3. Choose suitable port, and input correct parameter on setting APP interface as below.
3.1 Network parameter
APN:
User name: (Tips: if the sim card have no user name, then no filled)
Password: (Tips: if the sim card have no user name, then no filled)
3.2 DNP3.0 protocol parameter
Master link address : 1
(note: it means SCADA server address, set as :Source in SCADA server)
Slave (Destination) link address:3
(note: it means RTU address ,set as: Destination in SCADA server)
Port: 20000
Tips: According DNP3.0 protocol define, the below setting is standard, normally, it is no need to change. If user SCADA system is really different, then Change it by professionals.
3.3 IEC104 protocol parameter
3.3.1 Msg Timeout. T1 default: 15s
3.3.2 Msg Timeout.T2 default: 10S
3.3.3 Msg Timeout. T3 Default: 30S
Remark:
T1, T2, T3. It use for the network state have a timeout value. It makes SCASA system between Terminal communication have a timeout buffer. If want to change, it need to according SCADA system communication speed to adjust the T1,T2,T3 value big or small.
Suggest, not to change it, otherwise professor is available to change it.
3.3.4 ASDU Address Default:3.
3.3.5 Port : 2404
(More detail, please contact with the relate Engineer.)
III. Terminal RTU upload data
The SNV309 -EFI RTU is supported to upload with Max.12 set Grounding fault indicators.
The upload data related the connect number on the SNV309-EFI terminal No. (From 1#, 2#...12#). Through the SCADA , It can achieve the below main performances.
1) When Grounding fault indicator detect a grounding fault, then it can upload the fault signal to SCADA.
2)Through SCADA, Operator can operate to Remote reset the indicator, or Test the indicator
Ø SNV309-EFI, DNP3 Data Objects
Supported DNP3 data objects
1. Binary input - with flags
Group: 1 | Variation: 2 | |
Function code: | 0x01 (READ) | |
Supported Qualifier: | 0x00, 0x01, 0x06 | |
Data point quantity: | 56 |
2. Analog input - single-precision, floating-point with flags
Group: 30 | Variation: 5 | |
Function code: | 0x01 (READ) | |
Supported Qualifier: | 0x00, 0x01, 0x06 | |
Data point quantity: | 42 |
3. Class 0 objects
Group: 60 | Variation: 1 | |
Function code: | 0x01 (READ) | |
Supported Qualifier: | 0x06 | |
Brief: | Get all of the static data |
4. Time and date
Group: 50 | Variation: 1 | |
Function code: | 0x02 (WRITE) | |
Supported Qualifier: | 0x07 | |
Brief: | Set absolute time |
5. Binary output - packed format
Group: 10 | Variation: 1 | |
Function code: | 0x02 (WRITE) | |
Supported Qualifier: | 0x07 | |
Brief: | Reset or Test EFI device |
Annex.list of DNP3.0
Binary input point list (Signal)
Index | Name |
0 | EFI 1# , Fault |
1 | EFI 2#, Fault |
2 | EFI 3#, Fault |
3 | EFI 4#, Fault |
4 | EFI 5#, Fault |
5 | EFI 6#, Fault |
6 | EFI 7#, Fault |
7 | EFI 8#, Fault |
8 | EFI 9#, Fault |
9 | EFI 10#, Fault |
10 | EFI 11#, Fault |
11 | EFI 12#, Fault |
Analog input point list (Measure)
Index | Name | Unit |
0 | Terminal battery voltage | V |
1 | Solar panel voltage | V |
2 | Terminal temperature | ℃ |
3 | Mobile signal strength | dBm |
Binary output point list
1. Reset EFI
Index | Name |
800 | Reset all EFI, at same time |
801 | Reset EFI 1# |
802 | Reset EFI 2# |
803 | Reset EFI 3# |
804 | Reset EFI 4# |
805 | Reset EFI 5# |
806 | Reset EFI 6# |
807 | Reset EFI 7# |
808 | Reset EFI 8# |
809 | Reset EFI 9# |
810 | Reset EFI 10# |
811 | Reset EFI 11# |
812 | Reset EFI 12# |
2. Test EFI
Index | Name |
900 | Test all EFI, at same time |
901 | Test EFI 1# |
902 | Test EFI 2# |
903 | Test EFI 3# |
904 | Test EFI 4# |
905 | Test EFI 5# |
906 | Test EFI 6# |
907 | Test EFI 7# |
908 | Test EFI 8# |
909 | Test EFI 9# |
910 | Test EFI 10# |
911 | Test EFI 11# |
912 | Test EFI 12# |
Ø SNV309-EFI, IEC104 Data Objects
Annex.list of IEC104
1. Remote signal
ASDU type:
Type ID | Name | Abbreviation |
1 | Single-point information | M_SP_NA_1 |
List 1:
IOA | Name |
101 | EFI #1 Fault signal |
102 | EFI #2 Fault signal |
103 | EFI #3 Fault signal |
104 | EFI #4 Fault signal |
105 | EFI #5 Fault signal |
106 | EFI #6 Fault signal |
107 | EFI #7 Fault signal |
108 | EFI #8 Fault signal |
109 | EFI #9 Fault signal |
110 | EFI #10 Fault signal |
111 | EFI #11 Fault signal |
112 | EFI #12 Fault signal |
2. Remote Measurement
ASDU Type:
Type ID | Name | Abbreviation |
13 | Measured value, short floating point number | M_ME_NC_1 |
List 2:
IOA | Name |
201 | RTU Battery voltage(V) |
202 | Solar Panel Voltage(V) |
203 | RTU inside temperature (℃) |
204 | GPRS signal intensity (dBm) |
3. Remote control
ASDU type:
Type ID | Name | Abbreviation |
45 | Single command | C_SC_NA_1 |
List 3:
IOA | Name |
800 | Reset all EFI, at same time |
801 | Reset EFI 1# |
802 | Reset EFI 2# |
803 | Reset EFI 3# |
804 | Reset EFI 4# |
805 | Reset EFI 5# |
806 | Reset EFI 6# |
807 | Reset EFI 7# |
808 | Reset EFI 8# |
809 | Reset EFI 9# |
810 | Reset EFI 10# |
811 | Reset EFI 11# |
812 | Reset EFI 12# |
List 4:
IOA | Name |
900 | Test all EFI ,at same time |
901 | Test EFI 1# |
902 | Test EFI 2# |
903 | Test EFI 3# |
904 | Test EFI 4# |
905 | Test EFI 5# |
906 | Test EFI 6# |
907 | Test EFI 7# |
908 | Test EFI 8# |
909 | Test EFI 9# |
910 | Test EFI 10# |
911 | Test EFI 11# |
912 | Test EFI 12# |
4. SCADA Timing:
ASDU type:
Type ID | Name | Abbreviation |
103 | Clock synchronization command | C_CS_NA_1 |
IV. Attachment for RTU Led blinking define:
1) The big Green LED on Case outside
Normal running | Blinking type |
1、RTU star running | Light on: 150ms Light off:150ms, Blinking on : one times,Stop :2s. Recycling.. |
2、Connected with SCADA success | Light on: 200ms Light off:200ms, Blinking: two times,Stop: 2s, Recycling... |
None Normal state | Blinking type |
1、SIM problems: None SIM card; Need input APN password. Etc. | Light on:100ms light off:150ms, Blinking on: 3times,Stop:1s, Recycling blinking.. |
2、Connect network failed: Can not register network or build link failed | Light on:100ms Light off: 150ms, Blinking : 4,Stop: 1s, Recycling blinking.. |
3、MODEM module wrong: Module welding failed, or Module bad. | Light on:100ms Light off: 150ms, Blinking : 5,Stop: 1s, Recycling blinking.. |
2) LED on PCB in the case
PCB Position | Function | Description |
D4 | Blue color Led: | Normal light:it means searching network; Blinking light , light on:200ms,light off:200ms: It means :net work registered, or data connect link build Light Off:it means :power off |
D8 | Yellow color Led: | Normal state: Light off Blinking 3times: it means RTU detect a fault signal from EFI |
D7 | Green color Led: | Normal state: Light off Blinking light: RTU upload or Receive signal between SCADA |
D6 | Red color Led: | when MCU normal working, the Led keep blinking light. |
D5 | Indicating for power system of RTU | When the power system is normal, then it will be light on |
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao
- Phone86-13570657698-8621065
- AddressXiangzhou district Zhuhai,Guangdong
- Hot Sell for DIstribution Network ,current power fault location SNV-EKL3.2
- Underground indicators Earth fault indicator for smart grid SNV-EFI
- SNV-EKL3.2 Earth fault and short circuit indicator
- SNV-EKL4 V2.1 Earth Fault Indicator for MV Power Distribution Network
- SNV-EFI Earth Fault Indicator
- Control PDA for Fault Locator In Transmission Lines
- Grounding Faul Indicator earth fault indicator
- Electric Handcart and Ground Knife Integrated Protector
- fault locator of Power distribution equipment
- SNV-EKL4 V2.1 Earth Fault Indicator cable sensor
- Grounding Fault Sensor and Current Short Circuit Indicator
- 12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
- 12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
- SNV-EKL4 V2.1 short circuit fault sensor for distribution network
- Industrial intelligent dehumidifier for distribution cabinet
- Simulated Failure Remote Controller for Overhead Line Fault Indicator
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
- How to install Cable type earth fault and short circuit indicator EKL4
- How to install Cable type earth fault and short circuit indicator EKL4
- Cable short circuit and grounding fault indicator SNV-EKL3.2
- what is Overhead line short circuit and grounding fault sensor ?SNV308 FPI
- Vertical Break Isolating Switch Comprehensive Protection Device
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
- Medium-voltage Distribution System Short-circuit and Ground Fault Device
Popular Searches
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-