During the installation process, some key frequency converter parameters can be optimized to improve motor operation, but these parameters are usually not well configured. For the settings discussed in this article, it is first necessary to verify whether the parameters match those listed in the manufacturer's documents, and pay special attention to the engineering units.
Frequency converter thermal current
Thermal current refers to the maximum allowable current, which is different from full load current (FLA). Full load current is the maximum amperage allowed for long-term operation of the motor at rated power, while thermal current represents the current that can be applied briefly and safely by the frequency converter exceeding the standard rated power of the motor.
The thermal current parameters inform the frequency converter how much "extra" power can be processed without thermal faults. When the limit is exceeded, the frequency converter can trigger a fault before the motor overload occurs, thereby protecting the motor from the impact of thermal faults. When configuring the driving parameters of the motor current, users can find the full load current and motor service factor (SF) on the motor nameplate. Multiplying these two values can calculate the thermoelectric flow in amperes.
Pulse width modulation
Each frequency converter that supplies power to AC motors converts the line AC power into DC power, and then the frequency converter modulates it into an AC waveform. This modulation is achieved by turning on and off a fast pulse DC power supply to generate AC waves. The frequency converter adjusts the amplitude and frequency of the wave to rotate the motor at the desired speed. The pulse width modulation (PWM) switch frequency parameter regulates these pulses and adjusts them by changing the number of alternating current pulses that supply power to the motor.
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
4 digital inputs, 1 analog input, and 1 relay output.
Product specifications:
Starting torque: 180% at 3 Hz, 200% at 5 Hz (vector)
Carrier frequency: 1-15 KHz
Control method: SVPWM, V/F control, magnetic flux vector control
Output frequency: 0-650.00 Hz
Starting torque: 180% at 3 Hz, 200% at 5 Hz (flux vector)
Protection function: output short circuit, overcurrent/voltage, low voltage, motor overheating, IGBT overheating, grounding/leakage, communication abnormality protection
Cooling method: 0.4KW product natural cooling, other air cooling
Display functions: output frequency, output current, output voltage, output power, alarm recording (up to 12 sets), etc
LED light: frequency monitoring, voltage monitoring, current monitoring, motor operation indication, control mode indication, external operation panel indication
Surrounding temperature: -10~+50 ℃ (unfrozen)
Surrounding humidity: below 90% Rh (without condensation)
Storage temperature: -20~+65 ℃
Protection level: IP20
Related models:
ACS310-01E-02A4-2
ACS310-01E-04A7-2
ACS310-01E-06A7-2
ACS310-01E-07A5-2
ACS310-01E-09A8-2
ACS310-01U-02A4-2
ACS310-01U-04A7-2
ACS310-01U-06A7-2
ACS310-01U-07A5-2
ACS310-01U-09A8-2
ACS310-03E-01A3-4
ACS310-03E-02A1-4
Send Inquiry to This Supplier
You May Also Like
-
PR9268/203-000 Shock SensorNegotiableMOQ: 1 Bag
-
MC-4/11/10/400 ControllerNegotiableMOQ: 1 Bag
-
MC-4/11/03/400 Servo DriverNegotiableMOQ: 1 Bag
-
IS200TBA1H1C General ElectricNegotiableMOQ: 1 Bag
-
IS200TBCIH2C Emergency Protection Terminal BoardNegotiableMOQ: 1 Bag
-
IS220PDIAH1B Control SystemNegotiableMOQ: 1 Bag
-
IS200TRLYH1BNegotiableMOQ: 1 Bag
-
IS220PDOAH1BNegotiableMOQ: 1 Bag
-
IS420UCSCH1A Quad Core ControllerNegotiableMOQ: 1 Bag
-
IS420ESWBH3A Control SystemNegotiableMOQ: 1 Bag