- Acrel Electric Co., Ltd
- China Manufacturer with main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > Residual current relay > Remote Control Local control 4 current input Capacitor protection thermal overload switch for air compressor
Remote Control Local control 4 current input Capacitor protection thermal overload switch for air compressor
Negotiable
1 (Min.Order)
- 1000 per Month
- T/T Credit Card
You May Like
- RS485 Modbus-RTU Rich protection functions 3 voltage input motor protection switch thermal overload protector 120v
- earth fault indicator A complete set of thermal overload devices motor protection electronics for sale
- High Quality Smart Automatic AM2SE RS485 Communication thermal overload switch transformer protection relay
- Din rail Smart Circuit Earth Leakage Over Under Voltage Protector Relay Device Switch Breaker rs485
- Multi-function LCD leakage fault protective relay with RS485 modbus-RTU ASJ10L-LD1A/C monitors digital earth leakage relay
- leakage fault protective relay ASJ10L-LD1A monitors digital earth leakage relay
Product Description
Products Description
AM2SE Protection Relay
● A complete set of protection, related to the application;
● 4 current input, 3 voltage input, 8DI, 5DO;
● Auxiliary power supply adapts with AC220V, DC220V, DC110V, AC110V, DC48V, DC24V;
● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
● more than 200 sequence of event records, more than 400 system logs, and more than 10 seconds tripping context records;
● Powerfulgraphic programmable Logic.
AM2SE-H(Horizontal version)
AM2SE-V(Vertical version)
Technical Parameter
DC rated voltage | 220V, 110V, 48V |
permissive variation | -20%~+15% |
Ripple coefficient | not larger than 5% rated voltage |
AC rated voltage | 220V |
permissive variation | -10%~+10% |
Ripple coefficient | not larger than 5% |
Rated voltage input | AC100V or 100/√3V |
Rated current input | AC 5A/1A |
Frequency | 50Hz |
Operation time | -25℃~+55℃ |
Relative humidity | 5%~95%(No condensation and freeze inside) |
Atmospheric pressure | 66kpa ~ 106Kpa |
Protection Functions | AM2SE- | ||
V | H | ||
Overcurrent ( 3 stages, IDMT ) | ■ | ||
Earth fault ( 3 stages, IDMT ) | ■ | ||
Negative sequence overcurrent ( 2 stages, IDMT ) | ■ | ||
Auto-reclose | ■ | ||
Overload ( trip/alarm ) | ■ | ||
Under frequency | ■ | ||
Post-accelerated overcurrent | ■ | ||
I0 Post-accelerated overcurrent | ■ | ||
Overvoltage ( trip ) | ■ | ||
Undervoltage ( trip ) | ■ | ||
Self-produced over zero-voltage ( trip ) | ■ | ||
Residual overvoltage ( trip ) | ■ | ||
FC block | ■ | ||
Trip and close circuit supervision ( alarm ) | ■ | ||
Non-electricity ( trip/alarm ) | ■ | ||
Undervoltage ( alarm ) | ■ | ||
Overvoltage ( alarm ) | ■ | ||
Residual overvoltage ( alarm ) | ■ | ||
PT supervision ( alarm ) | ■ | ||
Self-produced over zero-voltage ( alarm ) | ■ | ||
Rear ports | V | H | |
RS485 | ■ | ||
Protocols | V | H | |
Modbus serial | ■ | ||
IEC 60870-5-103 | ■ | ||
Measurement | V | H | |
Electric parameter | U, I, P, Q, PF, Fr, Ep, Eq, Es | ||
Input current | 4 | ||
Input voltage | 3 | ||
Logs and Records | V | H | |
Fault recorder | ■ | ||
Sequence of event record | ■ | ||
Monitoring Functions | V | H | |
Anti-pumping circuit | Optional | ||
Remote control | ■ |
Wiring Illustration
Dimension & Installation
Solution Structure
Certification
Company Profile
FAQ
Title goes here.
Semi-Automatic PET Bottle Blowing Machine Bottle Making Machine Bottle Moulding Machine
PET Bottle Making Machine is suitable for producing PET plastic containers and bottles in all shapes.
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
New Products
- branch multi circuit multi channel energy Meter KWH meter RS485 modbus power meter 50A/50mA data center monitoring module
- three phase AMB100 data center Busway Monitoring Module 2-63rd harmonic measurement leakage current
- 2-way DC bus voltage AMC16Z-ZD data center multi circuit monitor Multi Channel Din Rail Power Meter outlet circuit monitoring
- Acrel data center monitor module three phase multi circuits monitoring 12 channels outlet
- 5A dual-circuits monitoring data center Multi Channels Din Rail Ac Power Meter outlet circuit monitoring full electric parameter
- data machine room electric usage monitor Acrel AMC16Z-KA 2 way unilateral 24 active switch states data center AC circuit monitor
- Acrel AMC16Z-KA 2 way unilateral 24 active switch states data center AC multi circuit monitor
- data center DC inlet monitor AMC16Z-ZD 2-way DC bus voltage Din Rail Ac Power Meter outlet circuit monitoring
- Acrel AMC16Z-ZA data center AC multi circuit monitor Multi Channel Din Rail Ac Power Meter outlet circuit monitoring
- data center AC multi circuit monitor AMC16Z-FAK24 two way AC outlet total 24 branch full electric parameter switch value
- AMC16Z-FAK48 Multi Channel Din Rail Ac Power Meter in array cabinet PDI's Branch Circuit Monitoring System
- data center AC multi circuit monitor AMC16Z-FAK48 Multi Channel Din Rail Ac Power Meter outlet circuit monitoring
- data center multi-circuits monitor energy consumption monitoring in array cabinet PDI's Branch Circuit Monitoring System
- multi-circuit monitor used in data center AMC16-DETT Base Station DC Energy Meter For 5G Tower data center monitoring device
- Tower base station DC48V DC36V electric deviceAMC16-DETT Base Station DC Energy Meter For 5G Tower data center monitoring device
- line transformer AM4-I feeder transformer post-acccelerated Residual over voltage overload under frequency External protection
- self-produced over zero-voltage supervision protection relay AM4-U2 undervoltage overvoltage protection Thermal overload
- AM4-U1 supervision protection relay undervoltage overvoltage protection Thermal overload under frequency External protection
- PT supervision midium voltage protection relay earth fault Thermal overload under frequency External protection
- midium voltage protection relay earth fault Overcurrent protection Thermal overload under frequency External protection
- multi-circuits monitoring device used in precision distribution box of data center
- AKH0.66 K-50 split core CTs 600A/5A current transformer
- APM830 Multi-function energy meter with panel installation
- AM3SE 35KV Microcomputer Medium Voltage Protection Device widely used in commercial buildings substation
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- MZZ1DTN156506 Closing latches for SIEMENS Vacuum Circuit Breaker
- EMHEATER Hot Sale EM10 EM15 3-Phase Frequency Inverter 220v
- PZ30 Power distribution box
- Weidmüller DIN rail power supply 1478130000 PRO MAX 240W 24V 10A
- TERASAKI TemBreak Circuit Breaker XH50NS XH100NS 3P 15A
- Siemens Timing relay 3RP2512-1AW30
- Pilz Safety relay 750104 PNOZ s4 24VDC 3 n/o 1 n/c
- Chauvin Arnoux Hand Digital Multimeter CA 5233
- Bosch Rexroth Hydraulics 4WRLE 25 0811404481
- Basler GigE camera aca2500-14gm
- Parker hydraulicvalve D1FPE50HB9NB00 D1FPE50MA9NB00
- UFC718AE01 HIEE300936R0101 Interface module for frequency converter
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile