NKVW vacuum pump unit is a vacuum pumping system consisting of a vacuum pump as the primary pump and a roots pump as the main pump. The vacuum relay or electric contact vacuum gauge is used to automatically start / stop the roots pump. The unit has the characteristics of fast startup, large pumping rate, and high ultimate vacuum 5Pa. The equipment is widely used in various industries such as vacuum smelting, welding, chemical and pharmaceutical, vacuum packaging, electric power project and so on.
Product Paramenters
Index | NKVW-250 | NKVW-500 | NKVW-1000 | NKVW-2000 | |||
Pump Speed (M3/H) | 250 | 500 | 1000 | 2000 | |||
Ultimate Vacuum (Pa) | ≤5 | ||||||
Working Vacuum (Pa) | ≤133 | ||||||
Power (kW) | 2.2 | 4.5 | 8.5 | 16.5 | |||
Power Supply | 380v, 50hz, 3Phase (Or According user demand) | ||||||
Weight (kg) | 350 | 450 | 650 | 1000 | |||
L | 880 | 1000 | 1250 | 1350 | |||
W | 600 | 700 | 850 | 1000 | |||
H | 1200 | 1500 | 1700 | 1800 |
Features
◆ This unit uses the roots pump as the main pump and the rotary vane vacuum pump as the primary pump. An electromagnetic vacuum inflation valve is connected in series between the primary pump and the main pump, and is opened and closed with the vacuum pump switch.
◆ Both the rotary vane vacuum pump and the roots pump adopt natural air cooling, compact structure, small volume, low noise, stable operation, and ensure long-term trouble-free operation of the vacuum pump unit, and long service life.
◆ The unit has phase loss and overload protection, which can prevent equipment damage caused by wrong operation and ensure that the vacuum pump unit can run safely under any circumstances.
◆ Install a filter at the air inlet of this unit to filter out impurities and moisture in the air, prevent impurities and water vapor from entering the vacuum pump unit, and protect the vacuum pump unit.
◆ The sealing part of the unit is sealed without leakage.
◆ The unit has the function of automatically starting and stopping the pump unit at the set value, that is, when the vacuum degree is lower than a certain set value (this value can be set and adjusted), the vacuum pump unit starts automatically. When the degree is increased to a certain set value (this value can also be set and adjusted), the vacuum pump set stops automatically.
Company Profile
Product packaging
Certifications
Contact Us
Contact Us
- Chongqing Nakin Electromechanical Co., Ltd.
Product Categories
New Products
- Breakdown Voltage Oil Tester/Insulating Oil Tester/ Transformer Oil Testing Device
- Dielectric Strength Oil Tester/Insulating Oil Testing Device For Testing Insulating Oil
- Series Breakdown Voltage Oil Tester For Testing Insulating Oil Dielectric Strength
- IIJ-II Breakdown Voltage Oil Tester,dielectric breakdown tester
- High Performance IIJ-II Transformer Oil Tester Plant,Breakdown Voltage Oil Analysis
- IEC156 International Standard IIJ-II Breakdown Voltage Oil Tester
- High Accuracy Dielectric Breakdown Voltage Oil Tester LCD Displayer
- Transformer Oil Test Device Breakdown Voltage Dielectric Strength Tester
- IIJ-II-80KV,100KV Transformer oil tester transformer oil BDV tester
- Transformer Breakdown Voltage Testing Laboratory BDV Tester
- IIJ-II Breakdown Voltage Oil Tester, oil testing device
- High Quality IIJ-II Dielectric Strength Tester Transformer Oil
- IEC156 standard 100KV Transformer oil breakdown voltage tester
- IIJ-II Automatic Oil Tester /Dielectric Strength /Breakdown Voltage
- BDV Oil tester, 100KV breakdown voltage oil tester
- Transformer oil BDV tester and transformer oil tester
- Dielectric strength tester, transformer oil tester device
- Breakdown voltage oil testing machine, oil tester
- Transformer Oil Breakdown Voltage Tester/Dielectric Strength Oil Tester
- Insulation Oil Test/Transformer Oil BDV Breakdown Voltage Tester Machine
- Automatic Transformer Oil Test Machine High Voltage Dielectric Strength Tester
- Transformer oil test equipment Transformer Oil Breakdown Voltage Testing
- Convenient Installation And Maintenance Test Oil Cup/Flash Point Tester/Oil Testing Device
- Easy Operation Closed Cup Flash Point Tester /Oil Tester For Testing Flash Point Of Petroleum Products
Popular Searches
Find Similar Products By Category
- Mechanical Parts & Fabrication Services > Pumps & Parts > Pumps
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- Services
- Latest Sourcing Requests
- Product Update
- Companies of Today
- GoldSupplier.com Mobile Site
- B2B Articles
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Contact supplier for lowest price
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-