Home > Products > IT Power Distribution > Acrel 300286 AIM-M200 insulation monitoring relay for hospital IPS monitoring system
Acrel 300286 AIM-M200 insulation monitoring relay for hospital IPS monitoring system
- 1000 Piece / Pieces per Month
- T/T Credit Card
- Acrel IP31 IT system electric power distribution isolation cabinet GGF-I6.3G used in CCU
- Acrel Hospital isolated power supply 7 pieces sets
- ACREL 300286 AIL100-8 insulation fault locator used in medical IT system
- ACREL (Stock Code:300286.SZ) Hospital IT medical insulation monitoring devices monitor the insulation resistance of IT systems
- ACREL (Stock Code:300286.SZ)insulation monitoring device for medical IT insulated isolation power system AIM-M200
- Isolated Power Monitor System for Hospital alarm indicator
Product Details
Brand Name: | Acrel | Place of Origin: | Jiangsu, China | Model Number: | AIM-M200 |
Packaging Details
Products are packed in caton box with air bubble film
Product Description
General
current transformers, the AIM-M200 is designed to support insulation fault location
Feature
● Load and temperature monitoring of isolation transformer
● Device disconnection monitoring
● LED indicators: On, Insulation, Overload, Overtemp
● Alarm relay output
● Test button
● Insulation fault location
● RS485 (MODBUS-RTU) + CAN (custom protocol
Display
Dimension
Wiring
Techinical Parameter
Input voltage | DC 18…36V | ||
Power consumption | ≤3VA | ||
Resistance measuring range | 10…999kΩ | ||
Response value | 50…999kΩ | ||
Relative uncertainty | ±10% | ||
Response time | ≤3s | ||
Measuring voltage U | ≤12V | ||
Measuring current I | ≤50uA | ||
Load current monitoring Measuring Value | 2.1…50A | ||
Load current monitoring Alarm Value | 5…50A | ||
Load current monitoring Measuring accuracy | ±5% |
Certificate
Company Profile
Acrel Co., Ltd.[stock code: 300286.sz] is a high-tech enterprise integrates R&D, production, sales and service, since its establishment, it committed to provide users with energy efficiency management and power security system solutions. Acrel Electric has a complete production line from cloud platform software to sensors. At present, more than 8,000 sets of various solutions are running all over the country, help users to realize the visual management of energy consumption, provide users the energy data services, and escort users an efficient and safe energy consumption.
Acrel energy efficiency management system including substation operations and maintenance cloud platform, electricity safety management cloud platform, Environmental equipment power consumption monitoring cloud platform, prepaid management (system) cloud platform, intelligent power distribution monitoring system, power quality management system, building energy consumption management system, industrial energy control platform, leakage power monitor and control system, fire-fighting device power monitoring system, fire-proof door monitoring system, emergency lighting and evacuation indicating system, EV charger management system, data center power&environment monitoring system, smart lighting control system, IT isolation power supply system and related products.
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim
- Phone86-1870-6168051
- AddressJiangyin Wuxi,Jiangsu
- Isolated Power Monitor System for Hospital Isolated Power System 10kv medical transformer
- Isolated Power Monitor System for Hospital Isolated Power System protection CT
- Isolated Power Monitor System for Hospital Isolated monitoring device
- Acrel 300286 hospital isolated power system supply for medical insulation failure assess
- Medical grade isolation transformer Equipment for insulation fault location for Hospital Isolated Power System
- Acrel 300286 Isolated Power Monitor System for Hospital Isolated Power System/insulation monitor for hospital
- Medical IT insulated isolation power cabinet for Hospital Isolated Power System
- Acrel AITR-6300 insulation system hospital isolated 6300kva medical isolation transformer
- Acrel AITR-6300 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-8000 insulation system hospital isolated 8kva medical isolation transformer
- Acrel 300286 AITR-10000 insulation system hospital isolated 10kva medical isolation transformer
- Acrel AITR-5000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-3150 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-8000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-5000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-5000 insulation system hospital isolated 5kva medical isolation transformer
- Acrel 300286 AKH-0.66P26 Medical isolation grade current transformer for Hospital Isolated Power System
- Acrel 300286 AID150 Medical isolation Nurse Station Alarm device for Hospital Isolated Power System
- Acrel AITR-8000 hospital isolated 230V isolation transformer for insulation system
- Acrel AITR-10000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-10000 hospital isolated 230V isolation transformer for insulation system
- Acrel AITR-6300 hospital isolated 230V isolation transformer for insulation system
- Acrel 300286 AClP10-24 Medical isolation power supply for Hospital Isolated Power System
- Acrel AITR-3150 hospital isolated 230V isolation transformer for insulation system
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Buy on GoldSupplier.com
- How to Buy
- Browse by Catagories
- Browse by Hot Regoins
- Private Sourcing Events
- Sell on GoldSupplier.com
- How to Sell
- Post Products
- Manage Products
- Manage Groups
- About
- About Us
- Link to Us
- Contact Us
- Sitemap
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-