1. INTENDED USE

Quicking Clenbuterol Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Clenbuterol residue in animals tissue

Cut-off:   5 ppb

Assay Time:  5 -10 min

Sample: Tissue

2. PRINCIPLE OF THE ASSAY 

Quicking Clenbuterol Rapid Test is based on competitive lateral flow immunochromatographic assay. The CLEN-conjugate in the test zone will capture the immuno-gold (colloid gold-CLEN antibody conjugate), when there is very little dissociative CLEN in the samples. A visible red test band indicates a negative result when the control line (C zone) shows that the card is valid. The test band (T zone) will be not visible if CLEN is present in concentration of ppb and above which explains a positive result. 


3. 
TEST PROCEDURE

Collect tissue as sample. Get rid of the fat tissue. Homogenize the sample at 10000 rpm for 1 min. Weigh out 4.0 g of sample into a 15 mL centrifugal tube. Add 0.5 mL of assay diluent and tightly cover the lid. 

Put the tube into a water bath for 10 min. Take out as much the extracted liquid into a 1.5 mL centrifugal tube.

Do centrifugation at 4000 rpm for 1 min to make the extract clear. 
Gradually drip 3 drops of sample extraction into the sample hole “S”.

Interpret the result in 5 - 10 min. Result after 10 min is considered as invalid.


4. 
INTERPRETATION OF RESULTS

PositiveOnly one clear band in zone indicates a positive result. Positive shows that the concentration of Clenbuterol is at or above ppin the sample.

Negative: The presence of both clear band in zone and zone. 

Invalid: No colored band appears in C zone. 

5. SPECIFICITY

The results are negative when the test is applied to detect 100 ppm of Ractopamine, Trenbolone-acetate, Chloramphenicol, Aminoglycosides, Beta-Lactams, Macrolides, Quinolones, and Sulfonamides.

The results is negative when the test is applied to detect 1 ppm of Salbutamol.   
   .

7. STORAGE

The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the foil pouchDO NOT FREEZE. Do not store the test kit in direct sunlight.