Home > Computer Products > Keyboard > Mechanical Keyboard > 3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control

3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control

3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control photo-1
Negotiable MOQ: 1 Piece (Price negotiable depending on order volume and customization)
Key Specifications
Get Latest Price
Brand Name:
Calibrator Supplier Platform
Place of Origin:
China
Model Number:
Calibrator Supplier Platform
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name Calibrator Supplier Platform
Place of Origin China
Model Number Calibrator Supplier Platform
Delivery Time:50 days
Certification:IEC, MID

 
3 Phase Electrical Test Meters Calibrators With Wireless Terminal Control
 


Usage:


AT1022 is suitable for the measurement departments of research institution, generating station, power grid corporation, railway, large industrial and mining enterprises and national measurement institution at all levels.
 

Main function


Calibrate indicating meter, digital meter, electric transducer, energy meter and so on;
Calibrate AC sampling RTU;
Output 2nd~63rd harmonics;
 


Main feature


Modular design, calibrate indicating meter, electrical transducer, RTU and so on;
8 inch color touch screen, interface friendly, easy to operate;
Equipped with RS232, Ethernet, and WiFi interface, AT1022 can either support stand-alone operation, PC 

control or handy wireless terminal control;
Communicate with tested meters thru RS485;
Automatically calculate the error of meter and transducer, and the related data can be downloaded thru 

U-disk;
Self-protection, alarming and displaying overload location for equipment output overload, Voltage short-circuit, Current open-circuit;
Automatically detect, diagnose and alarm for failure. 
Remotely updating online, easily achieve software updating;
Support calibrating by userself. 
 

Type:

AT1022C Electric meter calibrator. Class 0.05

AT1022B Electric meter calibrator. Class 0.1


AC large Voltage output:


Range: (Phase A) 30V, 100V, 300V, 660V, 1000V;
(Phase B, C) 30V, 100V, 300V, 660V;
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; Phase A 1000V: (0~100) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 30V and upper gears; 20VA each phase;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
 


 
AC small Voltage output:


Range: Phase A: 75mV, 300mV, 750mV, 3V, 7.5V;
Adjusting range: (0~120) %RG, RG refers to range; 
Adjusting range: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.02%/2min;
Distortion: ≤0.2% (Non capacitive load);
Max output load: ≥25mA;
Measurement accuracy: 0.1%RG;
 


 
AC Current output:


Range: (Phase A) 500uA, 2mA,10mA, 50mA, 200mA, 500mA, 2A, 5A, 10A, 30A;
(Phase B, C) 200mA, 500mA, 2A, 5A, 10A, 30A; 
Adjusting range: (0~120) %RG, RG refers to range, similarly hereafter; 
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG for option;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Distortion: ≤0.2% (Non capacitive load);
Max output load: 20VA (30A gear); 50mA and below gear: ≥15V;
Measurement accuracy: 200mA and above gears: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1);
                    50mA and below gears: 0.1%RG (Class 0.1);
 
 


Power output


Power output stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Active/reactive power measurement accuracy: 0.05%RG;
 


Phase output


Output adjusting range: 0°~360°;
Output adjusting degree: 10°, 1°, 0.1°, 0.01° for option;
Resolution: 0.01°;
Measurement accuracy: 0.05°.
 


Power factor output:


Adjusting range: -1 ~ 0 ~ +1;
Measuring resolution: 0.0001;
Measurement accuracy: 0.0005
 


Frequency output


Adjusting range: 40Hz ~70Hz;
Output adjusting degree: 1Hz, 0.1Hz, 0.01Hz, 0.001Hz for option;
Resolution: 0.001Hz;
Accuracy: 0.002 Hz.
 


Harmonic setting


Harmonic order: 2nd ~63rd;
Harmonic amplitude: 0~40%;
Harmonic angle: 0°~359.99°;
Harmonic set error: 2nd ~31st: ≤±0.1%,32nd ~63rd: ≤±0.2%;
 


DC Voltage output


Range: 100mV, 300 mV, 1V, 5V, 20V, 100V, 300V, 1000V;
Adjusting range: (0~120) %RG; 1000V: (0~100) %RG
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output load: 20V and above ranges ≥10mA;5V and below ranges≥50mA;
Measurement accuracy: 0.05%RG (Class 0.05); 0.1%RG (Class 0.1)
Ripple content: no more than 1%.  
 


DC Current output


Range: 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1A, 5A, 10A, 25A;
Adjusting range: (0~120) %RG;
Adjusting degree: 0.01%RG, 0.1%RG, 1%RG, and 10% RG;
Stability: 0.01%/2min (Class 0.05), 0.02%/2min (Class 0.1)
Output lo

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location
Huzhou, Zhejiang, China

Recommended Categories