GV series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, rated voltage up to 660V, rated current 0.1-80A prower circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.
| Type | Standard power ratings of 3-phase motors 50/60Hz in category AC-3 | Setting range | |||||
| 220V | 380V | 415V | 440V | 500V | 660V | ||
| kW | kW | kW | kW | kW | kW | ||
| GV1-M01 | - | - | - | - | - | - | 0.1-0.16 |
| GV1-M02 | - | - | - | - | - | - | 0.16-0.25 |
| GV1-M03 | - | - | - | - | - | - | 0.25-0.4 |
| GV1-M04 | - | - | - | - | - | 0.37 | 0.4-0.63 |
| GV1-M05 | - | - | - | 0.37 | 0.35 | 0.55 | 0.63-1 |
| GV1-M06 | - | 0.37 | - | 0.55 | 0.75 | 1.1 | 1-1.6 |
| GV1-M07 | 0.37 | 0.75 | 1.1 | 1.1 | 1.1 | 1.5 | 1.6-2.5 |
| GV1-M08 | 7.5 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | 2.5-4 |
| GV1-M10 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | 4-6 |
| GV1-M14 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | 6-10 |
| GV1-M20 | 4 | 7.5 | 7.5 | 7.5 | 10 | 11 | 10-16 |
| GV1-M21 | 5.5 | 10 | 9 | 9 | 11 | 15 | 16-20 |
| GV1-M22 | 5.5 | 11 | 11 | 11 | 15 | 18.5 | 20-25 |
| GV2-M01/RS01 | - | - | - | - | - | - | 0.1-0.16 |
| GV2-M02/RS02 | - | - | - | - | - | - | 0.16-0.25 |
| GV2-M03/RS03 | - | - | - | - | - | - | 0.25-0.4 |
| GV2-M04/RS04 | - | - | - | - | - | 0.37 | 0.4-0.63 |
| GV2-M05/RS05 | - | - | - | 0.37 | 0.37 | 0.55 | 0.63-1 |
| GV2-M06/RS06 | - | 0.37 | - | 0.55 | 0.75 | 1.1 | 1-1.6 |
| GV2-M07/RS07 | 0.37 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | 1.6-2.5 |
| GV2-M08/RS08 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | 2.5-4 |
| GV2-M10/RS10 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | 4-6.3 |
| GV2-M14/RS14 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | 6-10 |
| GV2-M16/RS16 | 3 | 5.5 | 5.5 | 7.5 | 7.5 | 9 | 9-14 |
| GV2-M20/RS20 | 4 | 7.5 | 9 | 9 | 9 | 11 | 13-18 |
| GV2-M21/RS21 | 5.5 | 11 | 11 | 11 | 11 | 15 | 17-23 |
| GV2-M22/RS22 | 5.5 | 11 | 11 | 11 | 15 | 18.5 | 20-25 |
| GV2-M32/RS32 | 7.5 | 15 | 15 | 15 | 18.5 | 26 | 24-32 |
| GV3-M06 | - | 0.37 | - | 0.55 | 0.75 | 1.1 | 1-1.6 |
| GV3-M07 | 0.37 | 0.75 | 1.1 | 1.1 | 1.1 | 1.5 | 1.6-2.5 |
| GV3-M08 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | 2.5-4 |
| GV3-M10 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | 4-6 |
| GV3-M14 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | 6-10 |
| GV3-M20 | 4 | 7.5 | 7.5 | 7.5 | 10 | 11 | 10-16 |
| GV3-M25 | 5.5 | 11 | 11 | 11 | 15 | 18.5 | 16-25 |
| GV3-M40 | 11 | 18.5 | 22 | 22 | 25 | 33 | 25-40 |
| GV3-M63 | 15 | 30 | 33 | 33 | 40 | 55 | 40-63 |
| GV3-M80 | 22 | 40 | 45 | 45 | 55 | 63 | 56-80 |
Send Inquiry to This Supplier
You May Also Like
-
ABB AF75-30-11RT-72 1SBL417010R7211 20-60V DC 3-Pole Contactor for Motor ControlNegotiableMOQ: 1 Piece
-
Circuit BreakerNegotiableMOQ: 2000 Pieces
-
Circuit Breaker MCCB AEG Circuit Breakers(SPQV-63C20)US$ 21.2 - 25.84MOQ: 50 Pieces
-
EZD100E3100N EZD100E Circuit BreakerUS$ 0.1 - 1MOQ: 1 Piece
-
(Circuit Breakers) S201D16 Hot Sales!!NegotiableMOQ: 1 Piece
-
30A Automatic Transfer SwitchUS$ 40 - 60MOQ: 1 Set
-
Rice Cooker Bimetal Disc ThermostatUS$ 0.1 - 1MOQ: 10000 Pieces
-
Reversible Thermo Sensor With Indicator Single-use in Center Part/Temperature Indicating and Recording LabeUS$ 90 - 180MOQ: 40 Cases
-
E-T-A Thermal-Magnetic Overcurrent Circuit BreakersNegotiableMOQ: 1
-
Electric Circuit Breakers Overload Protector Switch OP-01AUS$ 0.1 - 0.3MOQ: 1 Piece