Home > Tools & Hardware > Power Tools > Electric Saw > Modbus RS 485 VOC Gas Detector / VOC Sensors For Air Measuring

Modbus RS 485 VOC Gas Detector / VOC Sensors For Air Measuring

Modbus RS 485 VOC Gas Detector / VOC Sensors For Air Measuring photo-1
US$ 4 - 5 MOQ: 1 Piece
Key Specifications
Get Latest Price
Brand Name:
NFCase
Place of Origin:
China
Model Number:
AIA-1
Payment & Shipping
Payment Methods:
Port of Shipment:
China
Delivery Detail:
7 days
Brand Name NFCase
Place of Origin China
Model Number AIA-1
Delivery Time:3-5 days
Certification:CE,FCC,MSDS
Specifications

Gas detected

VOCs ( toluene emitted from wood finishing and construction products);

Cigarette smoke( hydrogen, carbon monoxide);

ammonia and H2S, alcohol, natural gas and smell by people’s body.

Sensing element

Semiconductor mix gas sensor

Power supply

24VAC/VDC

Consumption

2.8 W

Response Time

<5 minutes for 90% step change

Warm up time

48 hours (first time), 1 hour (normal operation)

VOC’s measuring range

1~30ppm

Display resolution

0.1ppm

Temperature & Humidity Sensor

Temperature

Relative Humidity

Sensing element

NTC

Capacitive sensor

Measuring range

0~50℃

0 -95%RH

Accuracy

±0.5℃ (25℃, 40%-60%RH)

±4.5%RH (25℃, 40%-60%RH)

Display resolution

0.5℃

1%RH

Stability

±0.5℃per year

±1%RH per year

Analog output

0~10VDC linear output or PID control output, programmable selection

Output resolution

10Bit

Relay output

Two dry contact outputs with programmable selection to control VOC, temperature, humidity. Rated switching current 2A(220VAC/30VDC), resistance load

Modbus interface

Modbus RS-485 protocol. 19200bps(default)

15KV antistatic protection, independent base address, 31 max network nodes 

Operation temperature

0~50℃(32~122℉)

Operation humidity

0~95%RH,non condensing

Storage conditions

0~50℃(32~122℉)

Net Weight

280g    

Dimensions

120mm×90mm×24mm         

Installment standard

65mm×65mm or 2”×4” wire box

Interface connections (Max.)

10 terminals

Wiring standard

Wire section area <1.5mm2

Quality System

ISO 9001

Programming and selection

Via DIP switch and external push-buttons

Outputs (max.)

1~2 dry contact relay outputs, 1X0~10V output

 Features

1. Real time monitor ambiance air quality with a mix gas sensor

2. Japanese semiconductor gas sensor with 5~7 years long life

3. Monitor temperature and relative humidity

4. LCD display air quality as well as temperature and humidity, fan status etc. Makes reading and operating easy and accurate.

5. user-friendly setting buttons

6. Temperature and humidity compensation makes the IAQ measurement more consistent in different environments

7. Modbus RS-485 communication interface optional, 15KV antistatic protection, independent base address setting

8. Up to 1x0~10V analog output and 2xrelay dry-contact outputs

9. Two alternatives for the analog output : linearized over full range output or PID control output.

10. The relays can be selected to control IAQ , temperature or humidity (programmable setting)

11. Timer of turning-off function for the ventilator device from 0.5 to 12 hours.

12. Low power consumption

Application

Send Inquiry to This Supplier

Message
0/5000

Want the best price? Post an RFQ now!
Business Type
Trading Company
Total Employees
101 - 200 People
Main Markets
North America, South America, Eastern Europe
Location