48V 50Ah UPS Replacement Batteries for Telecom Base Station / Back Up Power Supply Battery
Certification:ROHS ,MSDS ,TLC certification,CE
48V50Ah UPS repalcement storage battery used for telecom base station,backup power supply
Specification :
|
Model |
Standard voltage |
Standard capacity |
mm Dimension |
kg Weigh |
Remark |
|
SDDX-4850 |
48V |
50Ah |
440*400*133 |
35±1 |
3U Cubical |
|
configuration |
cell 3.2V50Ah ,16S single battery in series |
||||
|
Working temperature |
-20℃~60℃ |
||||
|
Storage temperature |
-10℃~65℃ |
||||
|
Relative humidity |
≤90%(40℃±2℃) |
||||
|
Altitude |
0~5000 m |
||||
|
Charge mode |
Intelligent interrupt charge |
||||
|
Average total voltage |
56.80V |
||||
|
Cell Average voltage |
3.55V |
||||
|
Float total voltage |
54.40V |
||||
|
Cell float voltage |
3.40V |
||||
|
Charge current |
55.0A |
||||
|
Cell overvoltage alarm |
3.65V |
||||
|
Cell overvoltage alarm recover |
3.60V |
||||
|
Cell overvoltage protection |
3.80V |
||||
|
Cell overvoltage protection |
3.60V |
||||
|
Total voltage overvoltage alarm |
58.0V |
||||
|
Total voltage overvoltage alarm |
54.0V |
||||
|
Total voltage overvoltage protection |
59.0V |
||||
|
Total voltage overvoltage protection |
54.0V |
||||
Description:
This product are based on the telecom operator are suitable for the latest back-up power supply under the new communication trend for development ,with integration , miniaturization, Light-duty Intelligentize , standardization ,Green Environmental Protection etc
The LiFePO4 battery pack with IBS models system and consist of 16S single 3.2V50AH cell and BMS system place to 19 inch 3U standard rack crate.
Multiple modules can be connected in parallel to increase the output power and capacity ,can set the each back up power address via address switch , then by connect with RS485 interface to cascade communication .this system operate environment temperature is around -20~60℃,the volume is small and light-weight ,easy to install and maintenance .
Applications:
1.widely used in Indoor Distributor System , Integrated station system , Connectsite,Microcell station, FTTX equipment ,WLAN equipment ,
2. RRU, distributed power supply and other telecom industry , also can apply in Access equipment , remote exchange multiplex, mobile communication equipment ,
3. Transfer equipment ,movement emergence communication bus ,traffic and fire protection emergence communication system , satellite earth station, Microwave communication equipment etc .
Competitive Advantage:
LiFePo4 battery pack with safe, longer cycle life and replace life Material and production is Green and Environmental Integrated system: 16pcs battery models in series + BMS system+ standard Chassis Rack installation dimension ,strictly refer to EIA,ETSI standard ,to meet with the way of the wall-mounted installation. With high energy density, discharge voltage is stabilize, can lengthen the cycle life. Module design, Multiple modules can be connected in parallel to increase the output power and capacity
Send Inquiry to This Supplier
You May Also Like
-
Self-fusing Electrical Silicone Rubber Hose Leak Waterproof High Pressure Plumbing Repair Tape Silicone Self Fusing TapeNegotiableMOQ: 1 Roll
-
Insulating TapeUS$ 0.27 - 0.69MOQ: 1000 Pieces
-
Air Conditioner Refrigeration HVAC Electrical Insulation Tape Pvc Insulating Tape PVC Insulation TapeNegotiableMOQ: 1
-
1mm White 100% Merino Wool Industry Pressed Wool Fel Free SamplesUS$ 3 - 10MOQ: 100 Square Meters
-
Silicon Rubber Pad Thickness 1.0,silicon Pad for SublimationUS$ 5 - 50MOQ: 10 Pieces
-
Polymeric Insulator Fittings Y Style FittingUS$ 3 - 5MOQ: 1000 Pieces
-
Cable Gland,cable Tie,terminal,connector,terminal BlocksUS$ 1 - 1MOQ: 6 Meters
-
The Supply of Thigh LetterNegotiableMOQ: 1 Meter
-
Transformer Crust (01)NegotiableMOQ: 1 Meter
-
Brushed Stainless Steel USB Interface Industrial Keyboard WithTrackballNegotiableMOQ: 1 Meter