CO2 / YAG Laser Dual Axis Optical Galvanometer Scanners for Diode Laser Marking Machine
Certification:ROHS / SGS
Dual Axis Optical Galvanometer Scanners for Diode Laser Marking Machine
Dual Axis Galvanometer Optical Scanners
Specifications:
|
Type of Optics |
Mirror Size: 3mm Aperture |
|
Coating |
1000Å Thick Low Pinhole, Protected Silver |
|
Current - Peak (A) |
Maximum: 8 |
|
Current - RMS (A) |
Maximum: 2.4 |
|
Power - RMS (W) |
Maximum: 30 |
|
Damage Threshold, CW (W/cm2) |
150 - 200 |
|
Maximum Drive Current (A) |
10 @ Peak, 5 @ RMS |
|
Substrate |
Silicon |
|
Rated Excursion, Rotor (°) |
±20 |
|
Bumper Stop Angle, Initial Contact (°) |
±26 |
|
Rotor Inertia (gm-cm2) |
0.018 |
|
Torque Constant (dyne-cm/A) |
27900 |
|
Coil Resistance (Ω) |
3.72 |
|
Coil Inductance (μhenries) |
109 |
|
Back EMF Voltage (μV/°/s) |
48.7 |
|
Position Signal (V) |
±10 |
|
Dimensions (inches) |
3.95 L x 3.05 W x 1.21 H |
|
Operating Temperature (°C) |
0 to +50 |
|
Power Requirement |
±15 to ±28V DC |
|
RoHS |
Compliant |
|
Type of Optics |
Mirror Size: 3mm Aperture |
|
Coating |
1000Å Thick Low Pinhole, Protected Silver |
|
Current - Peak (A) |
Maximum: 8 |
|
Current - RMS (A) |
Maximum: 2.4 |
|
Power - RMS (W) |
Maximum: 30 |
|
Damage Threshold, CW (W/cm2) |
150 - 200 |
|
Maximum Drive Current (A) |
10 @ Peak, 5 @ RMS |
|
Substrate |
Mirror: Fused Silica |
|
Rated Excursion, Rotor (°) |
±20 |
|
Bumper Stop Angle, Initial Contact (°) |
±26 |
|
Rotor Inertia (gm-cm2) |
0.018 |
|
Torque Constant (dyne-cm/A) |
27900 |
|
Coil Resistance (Ω) |
3.72 |
|
Coil Inductance (μhenries) |
109 |
|
Back EMF Voltage (μV/°/s) |
48.7 |
|
Position Signal (V) |
±10 |
|
Dimensions (inches) |
3.95 L x 3.05 W x 1.21 H |
|
Operating Temperature (°C) |
0 to +50 |
|
Power Requirement |
±15 to ±28V DC |
|
RoHS |
Compliant |
Description:
Dual Axis Galvanometer Optical Scanners provide superior positioning speed and accuracy precision than comparable compact, cost-sensitive, closed loop galvanometers. Featuring low inertias, compact sizes, and high speeds and accuracies, these galvos are ideal for applications including biomedical systems, optical coherence tomography, laser projection, confocal microscopy, and analytical instrumentation.
Competitive Advantage:
Dual Axis Galvanometer Optical Scanners,competitive price , good quality, delivery on time, providing perfect after-sales service, to provide customers with professional customized products of parameter. We will supply you with best solution.
Send Inquiry to This Supplier
You May Also Like
-
Circular Loom Spare Parts for Synthetic Fiber Production LinesNegotiableMOQ: 50 Sets
-
Tag Guns NeedleUS$ 2 - 2.55MOQ: 50 Pieces
-
Keestar Sewing Machine PartsNegotiableMOQ: 1 Set
-
Triangular Felt Needle for Nonwoven Felt Needle Punching MachineUS$ 0.02 - 0.07MOQ: 1000 Pieces
-
Plastic Staple AttacherUS$ 500 - 800MOQ: 1 Piece
-
Shrink Rap MachineUS$ 2,913 - 3,000MOQ: 1 Set
-
High Speed 1000W Laser Cutter For Metal , Small Laser Metal Cutting MachineUS$ 30000 - 100000MOQ: 1 Square Meter
-
Blue 58 Inch Cotton Velvet Fabric / Flock Fabric Roll for Packaging or DecorationNegotiableMOQ: 1 Square Meter
-
Sewing NeedlesNegotiableMOQ: 5000 Pieces
-
Sewing Machine NeedleNegotiableMOQ: 1000 Boxes