200A Remote Communication Low - Voltage Overload M60 Protection Controller / Motor Protection Relay
200A Remote Communication Low - Voltage Overload M60 Protection Controller / Motor Protection Relay
Profile
M60 protection controller is designed to provide full-scale protections and controls of low-voltage asynchronous motor and increasing safety motor rated below 800A, 50Hz, 380VAC. M60 measures the electrical parameters of motors, operates and controls the motors ,and equipped with the history record management and remote communication function.
M60 products portfolio: standard M60-1S and M60-3S, popular M60-2M and integrated M60-2P. With different infrastructure, installation, and functions, these four types of protector controllers can meet different requirements of customers in low-voltage protection area.Features
Variety of product portfolio to suit customers\' needs
Recording function to record the instant data before and after the faults for fault analysis purpose
Flexible protection functions configuration to ensure the safe and continuous production
Automatic software and hardware inspection to increase the stability and reliability
Remote or local operation on parameters setup, motor start, stop, and reset
Detection on the motor start status automatically to avoid malfunction
Configured with large size LCD panel for on-site operation (optional)
Technical Specification of M60-3S
Input (M60-3S)
Input Current: 1A, 5A, 6.3A, 25A, 50A, 100A, 160A, 200A, 250A
Remote digital signal input: 1 channel (dry contact)
Output (M60-3S)
RS-485 output: 1 channel
Analog output: M60-3S, 2 channels (4-20mA or 0-5V)
Relay output: 2 channels (dry contact)
Contact capacity of control output relay: 10A/250VAC
Contact capacity of alarm output relay: 10A/250VAC
Measurement Record (M60-3S)
Accuracy: I, class 0.5
Accumulated operating time on record (Max.): 9999days
Size & Weight: (M60-3S)
Installation: Panel mounting
Dimensional size: 96mmX48mmX76mm
Installation size: 94mmX46mm
Weight: 450g
Environment:
Auxiliary power supply: 85~265VAC/DC
Total power consumption: <3VA(M60-3S )
Operation temperature: -20℃ ~ +60℃
Storage temperature: -40℃ ~ +85℃
Operation humidity: <90%RH
Storage humidity: <95%RH
Protection Function:
|
Function |
Status |
Item |
Content |
M60-1S |
M60-2S |
M60-2M |
M60-2P |
|
Overtime start protection |
Programmable |
Allowed startup time |
0-80s |
Yes |
Yes |
Yes |
Yes |
|
Protection method |
2 |
||||||
|
Short circuit protection |
Programmable |
Fault setting range |
4-12le |
Yes |
Yes |
Yes |
Yes |
|
Execution delay time |
0.1-0.5s |
||||||
|
Protection method |
0, 2 |
||||||
|
Locked rotor protection |
Programmable |
Fault setting range |
200-950%le |
Yes |
Yes |
|
Send Inquiry to This Supplier
You May Also Like
-
Wifi Internet Bluetooth USB Radio With DAB+/DAB/FM ServiceUS$ 48 - 48MOQ: 1000 Sets
-
Satin Rose Sinamay Ladies Hats Church Red / Burgendy With Feather TrimNegotiableMOQ: 1 Set
-
Multifunction Currency Exchange Wall Mount Kiosk With Cash AcceptorNegotiableMOQ: 1 Set
-
OEM Heating & Cooling Injection Molding Temperature Controller Units EquipmentNegotiableMOQ: 1 Set
-
High - End Consumer SMT DIP 7 Layer PCB Printed Circuit Board PCB Assembly ServicesNegotiableMOQ: 1 Set
-
0-6kPa-7MPa 24VDC Diffused Silicon Differential Pressure Transmitter for Liquid and GasNegotiableMOQ: 1 Set
-
Toyota Smart Key Maker OBD(Support Toyota Lexus Smart Key)NegotiableMOQ: 1 Set
-
Outdoor Trunk Splitter VK11097US$ 0.1 - 0.99MOQ: 5000 Pieces
-
Receiver (Dia.31*12mm)US$ 0.1 - 1MOQ: 2000 Pieces
-
Antenna Manufacturer 650-850MHz 11dBi Directional Aluminum Yagi Uhf tv Transmitter AntennaNegotiableMOQ: 500 Pieces